Extech 382213 Handleiding
Extech
Multimeter
382213
Bekijk gratis de handleiding van Extech 382213 (4 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 27 mensen en kreeg gemiddeld 5.0 sterren uit 14 reviews. Heb je een vraag over Extech 382213 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

User Manual
Three Output DC Regulated Power Supply
Models 382203 (Analog) and 382213 (Digital)
Addional User Manual Translaons available at www.extech.com

2 382203- - -US_V2.0 8/19 382213 en
Introduction
Congratulations on selecting Extech's Model 382203 (analog) or 382213 (digital)
Regulated DC Power Supply. The 382203 and 382213 are solid state, compact, well
regulated supplies suitable for many applications including bench testing, field service,
hobby and telecommunication equipment use.
Meter Description
1. Voltage and Current LCD displays for Main output
2. Current limit status LED
3. Power switch with status LED
4. 5V 12V fixed output terminals &
5. Main Output terminals for variable supply
6. Variable voltage and current adjustment knobs
Model 382213 (Digital LCD display) is shown above.

3 382203- - -US_V2.0 8/19 382213 en
Operation
1. The Power Supply must be powered using the rated line voltage (120V or 220V)
within + 5%.
2. Before turning the power supply ON, remove all connected loads and set the Voltage
Adjustment Knob to the full counterclockwise position (0V DC output).
3. To operate the power supply as a constant current supply, the current output should
be set between 10% and 100% of the rated value (3A) .
4. The Current Limiting Indicator will light when the current limiting circuit is activated.
5. Constant Current setup (Main output only)
Set the current knob to the minimum position
Set the voltage knob to the maximum position
Short the output leads
Turn on the power supply
Turn the current knob to the desired current value (0.3 3.0 amps) ~
Turn off the power supply
Open the test leads (remove the short)
Connect the load and turn on the power supply
6. Use the Current and Voltage Adjustment knobs for setting variable Current and
Voltage output signals respectively. Use Variable Output terminals for connections.
7. For 5VDC and 12VDC outputs, use the Fixed Output terminals.
8. The analog or digital displays will indicate actual current and voltage outputs for the
main output.
9. Keep the meter's cooling vents ( p and sides) clear of obstacles to prevent to
overheating.
Product specificaties
Merk: | Extech |
Categorie: | Multimeter |
Model: | 382213 |
Heb je hulp nodig?
Als je hulp nodig hebt met Extech 382213 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Multimeter Extech
23 November 2024
27 November 2023
27 November 2023
27 November 2023
27 November 2023
10 Juni 2023
10 Juni 2023
10 Juni 2023
10 Juni 2023
7 Juni 2023
Handleiding Multimeter
- Gossen Metrawatt
- Horex
- Stanley
- Testboy
- Metrel
- IWH
- TFA
- REV
- Altai
- Qian
- Digi-tool
- Cosinus
- Profile
- Kyoritsu
- Milwaukee
Nieuwste handleidingen voor Multimeter
7 Juni 2025
4 Juni 2025
3 Juni 2025
2 Juni 2025
30 Mei 2025
30 Mei 2025
30 Mei 2025
3 April 2025
3 April 2025
3 April 2025