Bekijk gratis de handleiding van Emko ESM-3722 (2 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 69 mensen en kreeg gemiddeld 4.8 sterren uit 4 reviews. Heb je een vraag over Emko ESM-3722 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/2

2.2PanelCut-Out
ESM- 77x35DINSizeHatcherController3722
InstructionManual.ENGESM-372201V0402/15
2.GeneralDescription
2.1FrontViewandDimensionsofESM-3722HatcherController
All order information of ESM-3722 Hatcher Controller are given on the table at above. User may form
appropriate device configuration from information and codes that at thetableand convert it to the
orderingcodes.Firstly,supplyvoltage then otherspecificationsmust bedetermined.Please filltheorder
code blanksaccordingto yourneeds.Please contactus, ifyourneeds areoutof thestandards.
10.OtherInformations
WhenSET buttonispressedfor3
seconds,“P”ledturn.Ifprogramming
modeenteringpasswordisdifferent
from0,programmingmodeentering
screenwillbeobserved.
MainOperationScreen
ProgrammingScreen
Changethevaluewithincrement
anddecrementbuttons.
Press SETbutton for accessing to the
parameter value. Press increment
button for accessing to the next
parameter, press decrement button for
accessingto the previousparameter.
Presssetbuttonforsavingthe
parameter.
Pressincrement buttonfor accessing to
the next parameter, press decrement
button for accessing to the previous
parameter.
ProgrammingMode
EnteringScreen
PressSET buttonfor
accessingtothe
passwordentering
PasswordEnteringScreen
Enterprogrammingmodeaccessing
passwordwithincrementand
decrementbuttons.
Note2: If programming mode accessing password is 0, onlythree parametersare accessible, and the
parameter valuescanbe changed.
PressSET/OKbuttonfor
enteringthepassword.
Note1: Ifprogramming
modeaccessingpassword
is0, TemperatureUnit
screen isobserved
insteadofprogramming
screen
If no operation is performed in programming mode for 20 seconds, device turns to main
operation screenautomatically.
i
DecimalSeparatorEnabling
SelectionScreen
5.5EnteringToTheProgrammingMode,ChangingandSavingParameter
14
13
3sec.
76mm/3inch
34,5mm/1.36inch
15
While buttonprotection parameter valueis0,1,2 or
4 inmainoperation screen if engine button is pressed,
manual engine start will be active.When the button is
released the engine startwill be passive and engine stops.
6. ManualStartofEggTrayRotatorOperationwithEngineButton
Note-1:If inputtypeisselectedPTC orNTC(B=2,3),Temperaturesensorisgiven withthe
device.Forthis reason, if input type isselected as PTC,sensor type (V =0,1 or 2) or if inputtype is
selectedas NTC, sensortype (V=0, 3or 4) mustbe declared inordering information.
8.Specifications
PasswordEnteringScreen
TemperatureUnitSelection
ParameterValue
TemperatureUnitSelection
ParameterValue
8.Specifications
c
1.2.GeneralSpecifications
1.Preface
ESM3722-HT seriesHatchercontrollersaredesignedforcontrollinghatcherprocess.Device
canbeusedeasilywithPIDorOn-Offcontrolformandmanualstartofeggtrayrotatorproperties.
ESM-3722
PowerSupply
Input
Output
Output
Output
2
Humidification
EggTrayRotatorOutput
Alarm
1.1EnvironmentalRatings
-4DigitsforTemperatureDisplay
-4DigitsforHumidityDisplay
-TemperatureSensorInput
NTC,PTC,PT-100,0/2..10V,0/4..20mA orProNemMiniPMI-P
(Mustbedeterminedinorder.)
-HumiditySensorInput
0/2..10V,0/4..20mA orProNemMiniPMI-P
(Mustbedeterminedinorder.)
-4Output
HeatingControlOutput
EggtrayrotatorOutput
HumidificationControlOutput
AlarmControlOutput
-RelayorSSROutputs(Mustbedeterminedinorder.)
-SelectableTemparatureControl(PIDorON/OFF)
- Auto-TunePID
-Setvalueboundaries
-ManualStartoftrayrotatorfromfrontpanel
- Alarmparametreters
- Adjustableinternalbuzzeraccordingtothealarmsituations
-Passwordprotectionforprogrammingmode,
ESM- 77x35DINSize3722
DigitalHatcherController
3 416
MountingClamp
PanelSurface
(maximumthickness15mm/0.59inch)
Frontpanel
IP65Protection
65mm/2.56inch
6mm/0.24inch
110mm/4.33inch(min)
71mm/2.79inch
29mm/1.14inch
50mm/1.97inch(min)
Maximum15mm/0.59inch
230V( %15)50/60HzV±
OptionalSupply
Voltage
-30V Z
115V( %15)50/60Hz
24V( %15)50/60Hz
24V( %15)50/60Hz
10
±
±
±
V
V
W
Standard
DeviceType
Housing&Mounting
ProtectionClas
Weight
EnviromentalRatings
Storage/OperatingTemperature
Storage/OperatingHumidity
Installation
OvervoltageCategory
PollutionDegree
OperatingConditions
SupplyVoltageandPower
TemperatureSensorInput
:HatcherController
:76mmx34.5mmx71mmPlastichousingforpanel
Panelcutoutis71x29mm.
:Ip65atfront,Ip20atrear.
: Approximately0.2Kg
:Standart,indooratanaltitudeoflessthan2000meterswith
nonecondensinghumidity.
:-40 Cto+80 C/-30Cto+80 C
:90%max.(Nonecondensing)
:Fixedinstallation
:II.
:II,officeorworkplace,noneconductivepollution
:Continuous
:
:115
:24
:24
:10-30
:NTC,PTC,PT-100,0/2..10V 0/4..20mAor
ProNemMiniPMI-P
o oo o
Z Z,
230V( %15)50/60Hz-1.5VA
V( %15)50/60Hz-1.5VA
V( %15)50/60Hz-1.5VA
V( %15)50/60Hz-1.5VA
V 1.5WZ
V
V
V
W
±
±
±
±
Output Heating
YourTechnologyPartner
www.emkoelektronik.com.tr
Thankyouverymuchforyourpreferenceto
useEmkoElektronikproducts,pleasevisitour
webpagetodownloaddetailedusermanual.
OperatingTemperature:
Max.OperatingHumidity:
Altitude :
0to50°C
90%Rh(non-condensing)
Upto2000m.
Forbidden Conditions:
Corrosive atmosphere
Explosive atmosphere
Homeapplications (The unitis only forindustrial applications)
Avisual inspection ofthis product forpossible damage occurredduring shipment isrecommended
before installation.
Itis your responsibility to ensure thatqualified mechanicaland electrical techniciansinstall thisproduct.
Ifthere isdangerof seriousaccidentresulting fromafailure ordefectin thisunit,power offthe system
and separate the electricalconnection of thedevice fromthe system.
The unit is normally suppliedwithout a power supply switch ora fuse. Use power switch andfuse as
required.
Be suretouse therated powersupplyvoltage toprotectthe unitagainstdamage andtoprevent failure
Keep thepoweroff until allofthe wiringiscompleted sothat electricshockand troublewith theunitcan
be prevented.
Never attempt todisassemble, modify or repair this unit.Tamperingwith the unit may results in
malfunction,electric shock orfire.
Do notusethe unitincombustible orexplosive gaseousatmospheres.
During putting equipment in hole onthemetalpanel while mechanical installation some metal burrscan
cause injuryonhands, youmustbe careful.
Montage of the product on a system must be done with it’s fixingclamps.Do not do the montage of the
device withinappropriatefixing clamp.Besure thatdevice willnotfall whiledoingthe montage.
Itis your responsibility if this equipment is usedin a mannernot specified inthis instruction manual.
EMKO Elektronik warrants that the equipmentdelivered is free from defectsin material and
workmanship.Thiswarranty isprovided foraperiod oftwoyears.The warrantyperiod startsfromthe
delivery date.This warranty isinforce if duty and responsibilities which aredeterminedin warranty
documentand instruction manualperforms bythecustomer completely.
Repairsshould only be performedby trained and specialized personnel.Cut power to the device before
accessing internalparts.
Do notclean thecasewith hydrocarbon-basedsolvents(Petrol, Trichlorethylene etc.).Use ofthese
solventscanreduce themechanical reliability ofthe device.Use a clothdampened in ethylalcohol or
waterto clean the external plastic case.
1.3Installation
1.4Warranty
1.5Maintenance
1.6ManufacturerCompany
ManufacturerInformation:
Repairandmaintenanceserviceinformation:
EmkoElektronikSanayive Ticaret A.Þ.
DemirtaþOrganizeSanayiBölgesiKaranfilSk.No:616369BURSA/TURKEY
Phone:+902242611900
Fax:+902242611912
EmkoElektronikSanayive Ticaret A.Þ.
DemirtaþOrganizeSanayiBölgesiKaranfilSk.No:616369BURSA/TURKEY
Phone:+902242611900
Fax:+902242611912
TemperatureSensor
Input
HumiditySensorInput
0/2..10V,0/4..20mA or
ProNemMiniPMI-P
5.2 AlarmOutputGraphicsofESM-3722HT
i
ProcessHigh Alarm
ON
OFF
Alarm
Output
Process Value
ProcessLow Alarm
ON
OFF
Alarm
Output
ProcessValue
Deviation Band Alarm
ON
OFF
Alarm
Output
(- AlarmSet)
=Process Set Value (Temperature orHumidity)
Deviation Range Alarm
ON
OFF
Alarm
Output
ProcessValue
AlarmSet AlarmSet
(+AlarmSet)
(- AlarmSet)(+AlarmSet)
ProcessValue
5.3EggTrayRotatorOperationGraphicsofESM-3722HT
Egg TrayRotator
Output Led
Egg TrayRotator
Output
ü
1-Screen Blinking TemperatureSensor failure . Sensor connection is wrong or there is no sensor
connection. Whilethis messageshown onthisdisplay,if buzzerfunction selectionis 3,5, 7 or8
internal buzzerstartsto operate.
5.4 FailureMessagesinESM3722HatcherController
2ScreenBlinking HSensorfailure .Sensor connectioniswrongorthere isno sensor
connection. Whilethismessage shownon thisdisplay,ifbuzzer functionselectionis 4,6,7or 8
internal buzzerstartsto operate.
- umidity
NTCinputtype
PTCinputtype
Termoresistanceinputtype
Humidityinputtype
Accuracy
SensorBreakProtection
ControlForm
RelayOutputs
OptionalSSRDriverOutput
TemperatureDisplay
HumidityDisplay
LEDDisplays
InternalBuzzer
Upprovals
:NTC(10k @25°C)
:PTC(1000 @25°C)
:PT-100IEC751(ITS90)
:0/2..10V 0/4..20mAMiniPMI-P
:±1%offullscale
:Upscale
:PIDorON/OFF
:5A@250V atResistiveLoad(HeatingOutput)
:3 A@250VatResistiveLoad(Humidificating, Alarm
andEggtrayrotatorOutput
:Maximum30mA,Maximum15V
:8mmRed4digitLEDDisplay
:8mmGreen4digitLEDDisplay
:P (Green),%(Green), C(Red),F(Red), Alarm(Red),
HumidifierOutput(Red),EggtrayrotatorOutput(Red)
HeatingOutput(Red),
: 83dB
:,
W
W
³
Z Z
V
V
, orProNem
o o
7. AutoTuneMetod
StartingAuto Tune (Limit Cycle Tuning)
Operation by the user:
•Adjust t
•Adjustauto tune selection parameter (=)
• In the main screenand Temperature value
are shouldalternately.
“Atun”
emperature controlon/off orPID parameter
( =1)
AutoTunemethod is used for determining PIDparameters used bythe device.
IfAuto Tune operationisfinished withoutanyproblem,
the device saves the newPID coefficients,calculated
using the previously found “T” and “B” values,to
memoryand continue torun.
parameter isadjustedautomatically.
Temperature
Value
Time
Heating
Output
Time
B
T
CancellingAuto Tune (Limit Cycle Tuning) operation :
1 -Ifsensor breaks;
2- Ifauto tune operation cannot be completed in 8 hours ;
3 -Ifuser adjustsparameter;
4-During auto tune operation if theuser changesthe temperature control from pid toon/off;
5- If processset valueis changed whileautotune operation isbeing performed;
Autotune iscanceled. “Atun”is notdisplayed. Then,without doingany changesin PID
parameters,device continues torun withprevious PID parameters.
3- In mainoperating screen if the upperdisplay is blinking, it meansthat temperature alarm exits and
alarmoutput is active .15ifbuzzer function selectionis,or8 internal buzzerstarts to operate.
4-In mainoperatingscreenifthe lowerdisplayisblinking,itmeans thathumidityalarmexitsand alarm
outputis active .26if buzzerfunction selectionis,or 8internal buzzer startsto operate.
B C D EFGHI/
/
UV W Z/
/ 0
PowerSupplyVoltageA
TemperatureSensorInputBScale( )°C/°F
ESM-3722
(77x35DINSize)
4
-20°C/-4°F; 80°C/176°F
115V( %15)50/60Hz-1.5VAV±
ProNemMiniPMI-P
PT 100,IEC751(ITS90)
1
PTC(Not-1)
2
5230V( %15)50/60Hz-1.5VAV±
8 10-30V1.5W
Z
0°C/32°F;100°C/212°F
0°C/32°F;100°C/212°F
NTC(Not-1)
3
0°C/32°F;100°C/212°F
324V( %15)50/60Hz-1.5VAV±
0
224V( %15)50/60Hz-1.5VAW±
0%-100%
0%-100%
0%-100%
0/2..10VdcVoltageInput
4
50/4..20mA CurrentInput
6
HumiditySensorInputC Scale(%)
ProNemMiniPMI-P
0/2..10VdcVoltageInput
4
50/4..20mA CurrentInput
6
01 RelayOutput(3A@250V ,atResistiveLoad,1NO)V
HumidifierOutput
FG
1RelayOutput(5 A@250V,atResistiveLoad1NC,1NO)V
HeatingOutputE
2SSRDriveOutput(Maximum30mA,Maximum15V)
01 RelayOutput(3A@250V ,atResistiveLoad,1NO)V
EggTryRotatorOutputHI
1RelayOutput(3A@250V ,atResistiveLoad,1NO)V
AlarmOutput
U
Temp.SensorwhichisgivenwithESM-3722
V
0None
3NTC-M5L20.K1.5 (NTCProbethermoplasticmouldedwith
1.5mcableforcoolingapplication)
4NTC-M6L50.K1.5 (
)
NTCProbestainlesssteelhousingwith
1.5mcableforcoolingapplication
9
ProNemMiniPMI-P (2for TemperatureandHumidity
application)
.5mcable
6
Customer
1PTC-M6L40.K1.5(PTC AirProbe1.5msiliconcable)
2PTCS-M6L30.K1.5.1/8”(PTCLiquidProbewith1.5msiliconcable)
A
Userdefined
Userdefined
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ESM-3722
ü
ü
PTC,NTC,PT-100
0/2..10V,0/4..20mA or
ProNemMiniPMI-P
Product specificaties
| Merk: | Emko |
| Categorie: | Thermostaat |
| Model: | ESM-3722 |
Heb je hulp nodig?
Als je hulp nodig hebt met Emko ESM-3722 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Thermostaat Emko
11 Juni 2024
27 November 2023
27 November 2023
27 November 2023
27 November 2023
27 November 2023
6 Juni 2023
Handleiding Thermostaat
Nieuwste handleidingen voor Thermostaat
16 Januari 2026
23 December 2025
22 December 2025
22 December 2025
22 December 2025
21 December 2025
20 December 2025
20 December 2025
19 December 2025
19 December 2025