Electia Gardsman CTC-1131 Handleiding

Electia Alarm ringer Gardsman CTC-1131

Lees hieronder de 📖 handleiding in het Nederlandse voor Electia Gardsman CTC-1131 (37 pagina's) in de categorie Alarm ringer. Deze handleiding was nuttig voor 27 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/37
24- -2009 APR
For ELECTIA
1
Table of Contents
Table of Contents
Table of Contents
Table of Contents Table of Contents
1. Application Overview ................................................................................................. 1
1.1. Identifying the parts .............................................................................................. 1
1.2. The Power Supply ................................................................................................. 2
1.3. Connecting the telephone line .............................................................................. 2
1.4. How to install the Control Panel ............................................................................ 2
1.5. Two-Level Passwords ............................................................................................ 2
1.6. Getting Started ..................................................................................................... 2
2. Conguring Your System .......................................................................................... 4
2.1. Entering Programming Mode ................................................................................ 4
2.2. Telephone Settings .............................................................................................. 4
2.3. General Settings ................................................................................................... 7
2.4. ADD/ Delete Device ............................................................................................ 14
2.5. Walk Test ........................................................................................................... 22
3. Operation ................................................................................................................. 23
3.1. Entering User Menu ............................................................................................ 23
3.2. Away (Alarm ON) Mode ...................................................................................... 23
3.3. Forced Arming ................................................................................................... 24
3.4. Disarm (Alarm o) Mode ................................................................................... 25
3.5. Home Arm Mode ................................................................................................ 25
3.6. Partial (By-pass) Arm Mode ................................................................................ 26
3.7. Alarm Activation ................................................................................................ 27
3.8. Stop the Alarm and Alarm Display ...................................................................... 28
3.9. Event Log ........................................................................................................... 29
3.10. Control PSS ....................................................................................................... 29
3.11. False Alarm Management .................................................................................. 30
3.12. Faulty Situations ............................................................................................... 30
3.13. Remote Access Via Regular Phone Lines ....................................................... 32
3.14. Dialing & Call Acknowledgment ........................................................................ 33
4. Appendix ................................................................................................................. 35
4.1. Reset Procedure ................................................................................................. 35
1
3
1. Application Overview
1.1. Identifying the parts
Backlit LCD Display
Microphone
Green LED
AC Power Indicator; the Green LED
will light up when AC Power is on.
Yellow LED
Fault Indicator; the Yellow LED will
light up when any fault situation is
detected and turn o when all fault
conditions are restored.
Numeric Keys
Key
In Programming mode, press this key
to move the cursor and scroll the
display upwards
Key
In Programming mode, press this key
to move the cursor and scroll the
display downwards.
Key
In Programming mode, use this key
for deleting a digit, canceling the
selection, aborting the current screen
and returning to the previous screen
etc.
OK Key
To conrm the keyed-in data or
conrm the selection.
# Key
To enter the Programming menu
For Telephone Number Setting; The
system will dial as it is entered.
Key
For Telephone Number Setting; it
represent 3-second delay when
dialing.
Buzzer
DC J ack
For connecting the DC 9V power
adapter.
Phone Jack Marked Line
This jack is for the connection to the
phone line from the wall.
Phone Jack Marked Phone
This jack is for the connection to
the telephone unit.
Two Mounting Holes
Battery Switch
7
8
4
5
9
1
2


Product specificaties

Merk: Electia
Categorie: Alarm ringer
Model: Gardsman CTC-1131

Heb je hulp nodig?

Als je hulp nodig hebt met Electia Gardsman CTC-1131 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Alarm ringer Electia

Handleiding Alarm ringer

Nieuwste handleidingen voor Alarm ringer