Installation Instructions
The Digital Bravo3 PIR detector is designed to provide maximum detection and
enhanced false alarm prevention in both residential and commercial applications. It uti-
lizes a microcontroller to weigh the strength of the digitalized PIR signal at different lev-
els (MLSP* algorithm) in order to provide effective detection of human motion.
The Digital Bravo3’s technology adapts to changing environmental conditions by adjusting critical detection parameters in order to
provide improved consistency of detection over all temperature ranges. The detector also provides excellent immunity to such false
alarm producing influences as RF, static and electrical transient. This technology, plus exceptional design care and careful factory
testing, ensure years of trouble free performance.
Four interchangeable lenses, wall or corner mounting and vertical adjustment provide application versatility. Your clients will
appreciate the small size and elegant simplicity of the case design.
The Digital Bravo3 has a 5-year warranty - your assurance of a trouble-free installation.
*Protected by the following patents: Canada 2099971 US 5444432
Select a detector location that will provide the coverage required. Consider the following to avoid false alarms:
Do not aim the detector at reflective surfaces such as mirrors or windows as this may distort the coverage pattern or reflect sun-
light directly onto the detector.
Avoid locations that are subject to direct high air flow such as near an air duct outlet.
Do not locate the detector near sources of moisture such as steam or oil.
Do not locate the detector in the path of direct or reflected (mirror) sunlight.
For premises with pets, use the pet alley lens.
Do not limit the coverage by large obstructions in the detection area such as plants or cabinets.
To open the case, use a small flat blade screwdriver and gently push in the tab at the bottom of the case and pull the cover straight
out at the bottom. Loosen the PCB screw, and push the board up as far as it will go. Using a small screwdriver, remove the appro-
priate knockouts for the mounting screws. Remove the left and/or right wiring entrance knockouts located at the top of the back-
plate. Mount the backplate to the wall using the screws supplied.
NOTE: Range and dead zones may vary due to settings.
Using the Mounting Height Chart (see back), set the vertical adjustment for the desired coverage. The height will be indicated by
the gauge located at the bottom right hand corner of the circuit board. Ensure that the PCB retaining screw is tightened just enough
to prevent board movement.
Moving the circuit board down will increase the far range and move the near beams farther out from the mounting wall.
Moving the circuit board up will reduce the far range and bring the near beams closer to the mounting wall. Moving the board
down too much will cause the far beams to “look” above the target. As a result, the range may appear shorter.
There are two jumpers on the detector circuit board. JUMPER J1 will enable/disable the alarm LED. If J1 is OFF, the LED will not
operate on alarm. If J1 is ON the LED will operate on alarm.
Upon power up, if J1 is ON, the LED will blink on and off at one second intervals for 50 seconds to indicate warm-up period.
JUMPER J2 selects between normal and hostile operation. For a typical environment, the unit should be set to “normal” (J2 ON). If
the environment presents potential disturbances which cannot be avoided, set J2 to “hostile” (J2 OFF).
NOTE: When using the corridor lens, set J2 to ON.
The detector is supplied with the wall-to-wall lens (BV-L1). To change the lens, release the top tab and pull the lens holder out.
This action releases the lens. Insert the new lens with the GROOVES FACING INWARD. The bottom of the lens is indicated by two tri-
angular indentations. Ensure that the lens is centered and then reattach the lens holder. The lens holder will snap into place sealing
the lens into position.
NOTE: The corridor lens should not be used for corridors less then 6'/1.8m wide. Ensure the beams are aimed directly down the
centre of corridor.
IMPORTANT NOTE: Upon installation, the unit should be thoroughly tested to verify proper operation. The end user should be
instructed on how to perform a walk test weekly .
Once the detector has been set up, create motion in the entire area where coverage is desired by walking perpendicular to the lens
pattern. Should the coverage be incomplete, readjust or relocate the detector. Once coverage is as required, the alarm LED may be
disabled by setting J1 to OFF.
Instructions d’Installation
Le détecteur Digital Bravo3 est un détecteur de mouvement infrarouge conçu pour fournir
un maximum de détection de mouvement et pour améliorer la prévention des fausses
alarmes dans les installations résidentielles et commerciales.
Il utilise un microcontrôleur pour mesurer la force du signal à infrarouge à divers niveaux
(algorithme MLSP*) afin d’assurer une détection efficace des mouvements humains.
La technologie du Digital Bravo3 s’adapte aux changements des conditions de l’environnement en ajustant les paramètres essentiels
de détection afin de fournir une meilleure détection quelle que soit la température. Le détecteur possède également une excellente
immunité aux fausses alarmes provoquées par les radiofréquences, l’électricité statique et les courants transitoires. Cette technologie
ainsi que la conception extrêmement soignée et les tests en usine minutieux, assurent des années performantes sans problème.
Quatre lentilles interchangeables, une installation au mur ou dans un coin et un réglage vertical offrent une polyvalence d’emploi
qui sera appréciée par votre client, en plus des dimensions compactes de l’appareil et de la simplicité élégante du boîtier.
Notre modèle Digital Bravo3 possède une garantie de cinq ans–votre assurance d’une installation sans problème.
*Protégé par les brevets suivants : Canada 2099971 US 5444432
Choisir un emplacement offrant la couverture nécessaire en tenant compte des problèmes potentiels suivants:
Ne pas orienter le détecteur sur des surfaces réfléchissantes telles que des miroirs ou des vitres. Cela pourrait altérer la couver-
ture ou provoquer la réflexion des rayons du soleil directement sur le détecteur.
Éviter les emplacements soumis à un débit d’air élevé tels que les environs de la sortie d’un conduit d’air.
Ne pas installer le détecteur à proximité de sources d’humidité comme de vapeur ou d’huile.
S’il y a des animaux sur les lieux, utiliser la lentille «passage pour animaux».
Ne pas orienter le détecteur de façon à ce qu’il reçoive des rayons lumineux solaires directs ou réfléchis.
Ne pas limiter la couverture en plaçant des obstructions, comme des plantes ou des armoires, dans la zone de détection.
Pour ouvrir le boîtier, utiliser un petit tournevis à tête plate et pousser avec soin la languette de la partie inférieure du boîtier, puis
tirer le couvercle tout droit par le dessous. Desserrer la vis de la carte de circuit imprimé et pousser la carte aussi haut que possible.
À l’aide d’un petit tournevis, enlever les alvéoles défonçables appropriées pour les vis de montage. Enlever l’alvéole de gauche et/
ou de droite pour entrée de câble sur la partie supérieure de la plaque arrière. Installer la plaque arrière à l’aide des vis fournies.
NOTE: La portée et la zone morte peuvent varier selon les réglages.
En consultant le tableau de la pore en fonction de la hauteur d’installation, effectuer le réglage vertical de façon à obtenir la couverture
désirée. S’assurer que la vis de fixation de la carte de circuit imprimé est juste assez sere pour emcher le mouvement de la carte.
En déplaceant le PCB vers le bas, la portée du détecteur augmentera et les faisceaux s’éloingneront du mur sur lequel le détecteur est
situé. En déplaceant le PCB vers le haut, la portée du détecteur diminuera et les faisceaux s’approcheront au mur sur lequel le détecteur
est situé. Si l’on déplace trop en bas, les faisceaux “regarderont” au dessus du cible. En conséquence, la portée semblera plus courte.
Il y a deux cavaliers sur la plaquette de circuit du détecteur . CAVALIER J1: Ce cavalier permet de mettre en circuit/hors circuit la DEL
d’alarme. Si J1 n’est PAS enfiché, la DEL ne s’allume pas durant une alarme. Si J1 est enfiché, la DEL s’allume durant une alarme.
Lors de la mise sous tension, si J1 est enfiché, le DEL clignotera à des intervalles d’une seconde pendant 50 secondes pour indiquer
un temps de réchauffement.
CAVALIER J2 permet de sélectionner un fonctionnement normal ou hostile. Dans des conditions typiques, l’appareil doit être réglé
sur « normal » (J2 enfiché). Si l’environnement présente un potentiel de perturbations inévitables, ne pas enficher J2, de façon à
choisir le fonctionnement « hostile ».
NOTE: En utilisant la lentille couloir vous devez enficher J2 (fonctionnement rapide).
Le détecteur est fourni avec la lentille «mur à mur» (BV-L1). Pour changer la lentille, débloquer la languette supérieure et enlever
le porte-lentille en le tirant. Cela dégage la lentille. Insérer la lentille avec les rayures vers l’intérieur. Le dessous de la lentille est
identifié par deux entailles triangulaires. S’assurer que le centrage horizontal de la lentille est adéquat, puis remettre en place le
porte-lentille. Lorsque le porte-lentille s’enclenche, la lentille est fixée en position.
NOTE: La lentille «couloir» ne devrait pas être utilisé dans un couloir moins de 6 pi./1.8 mètres de largeur. Assurez-vous que les
faisceaux sont dirigés en bas du centre du couloir.
NOTE: Dès que l’installation est complète, testez le détecteur pour vous assurer d’une opération adéquate. Expliquez à votre cli-
ent comment effectuer un essai de marche.
Une fois le détecteur réglé, effectuer un essai de marche sur toute la zone de couverture désirée. Si la couverture est incomplète,
régler de nouveau le tecteur ou l’installer à un autre endroit afin d’obtenir une couverture complète. Une fois la couverture
désirée obtenu, la DEL de l’alarme peut être mise hors circuit en n’enfichant pas J1.
Instrucciones de instalación
El Digital Bravo3 detector PIR es diseñado para ofrecer una detección máxima y la
prevención superior contra alarmas falsas en aplicaciones comerciales y residenciales.
Utiliza un microcontrolador para medir la intensidad de la señal digitalizada PIR en nive-
les diferentes (algoritmo MLSP*) para brindar detección eficaz de movimiento humano.
La tecnología del Digital Bravo3 se adapta a los cambios de condiciones medioambientales una ajustando los parametros criticos
de detección sobre todo las gamas de temperatura. El detector proporciona también una inmunidad excelente contra las influencias
que producen alarmas falsas tal como RF, estática y transitorios eléctricos.
Las cuatro lentes intercambiables, montaje en la pared o esquina y el ajuste vertical proporcionan una aplicación versátil, y sus cli-
entes apréciarán el tamaño pequeño y elegante del diseño de la cubierta.
El Digital Bravo3 tiene una garantía de 5 años - su seguro de una instalación libre de fallas.
*Protegido por las siguientes patentes: Canadá 2099971 US 5444432
Seleccione una ubicación para el detector que va a proporcionar la cabertura requerida, teniendo en cuenta los siguientes proble-
mas potenciales.
No dirija el detector a superficies reflectoras tales como espejos o ventanas p1-ya que esto puede distorsionar el patrón de
cubrimiento o reflejar directamente la luz solar en el detector.
Evite ubicaciones que estén sujetas a altas corrientes de aire tales como, cerca a un conducto de aire.
No instale el detector cerca de fuentes de humedad tal como vapor, aceite.
No dirija el detector de tal forma que reciba en forma directa o reflejada (espejo) la luz solar.
Si hay mascotas en el local, use los lentes Pet Alley
No limite la cubertura dentro del área de detección con de objetos grandes tales como plantas o archivos.
Para abrir la cubierta, utilice un destornillador de punta plana pequeña y suavemente empuje la lengüeta en la parte inferior de la
caja y tire la cubierta directamente hacia abajo. Afloje el tornillo del tablero del circuito y empuje el tablero hacia arriba hasta
donde sea posible. Usando un destornillador pequeño, retire los prepunzonados apropiados para los tornillos de montaje. Retire los
prepunzonados izquierdos y/o derechos para las entradas del cableado que están colocados en la parte superior de la plaqueta.
Instale la plaqueta de montaje usando los tornillos provistos.
NOTA: Los alcances y zonas muertas pueden variar debido a los ajustes.
Usando el Diagrama de la Altura de Montaje (a continuación), fije los ajustes verticales para conseguir la cobertura deseada. La
altura será indicada por la escala localizada en la ezquina inferior a la derecha del tablero del circuito. Asegúrese que el tornillo
para retener el PCB, esté ajustado lo suficiente para evitar el movimiento del tablero.
Moviendo el tablero del circuito hacia abajo aumentará el alcance lejano y trae los más cerca a la pared de montaje.
Moviendo el tablero del circuito hacia arriba, reducirá el alcance lejano y moverá los rayos infrarojos más cerca de la pared de
montaje. Moviendo el circuito del tablero demasiado arribacausará los rayos infrarojos “miren” por encima del punto; como
resultado, el alcance puede parecer más corto.
Hay dos puentes, en el tablero del circuito del detector. Puente J1 habilitará/inhabilitará el LED de la alarma. Si J1 no está en
posición, el LED no operará en alarma. Si J1 está en posición cerrada, el LED operará en alarma.
En el momento de encender, si J1 está en posición cerrada, el LED destellará en intervalos de un segundo por 50 segundos para
indicar un periodo de inicialización.
Puente J2 selecciona entre una operación normal y hostil. Para ambientes normales, la unidad debe ser fijada en ”normal” (J2 en
posición cerrada). Si el ambiente presenta disturbios potenciales que no puede ser evitados, fije el J2 en “hostil” (J2 en posición
abierta).
NOTA: Con el lente corredor, fije J2 en posición cerrada.
El detector es suministrado con el lente “pared a pared”. Para cambiar el lente, libere la lengüeta posterior y tire el lente hacia afu-
era. Esta acción libera el lente. Inserte el lente con la ranura de frente hacia la parte interna. La parte inferior del lente es indicada
por dos mellas triangulares. Asegúrese que el lente esté centrado de izquierda a derecha y después vuelva a instalar el soporte del
lente. El soporte del lente cerrará en su lugar, sellando el lente en posición.
NOTA IMPORTANTE: En el momento de la instalación, la unidad debe ser probada completamente para verificar una correcta
operación. El usuario debe ser instruido sobre como realizar una prueba de paso semanalmente.
Una vez que el detector ha sido instalado, realice un movimiento en el área completa donde se desea la cobertura caminando per-
pendicularmente al patrón del lente. Si la cobertura esincompleta, vuelva a ajustar o a ubicar el detector. Una vez que et la
cobertura está como es requerida, el LED de alarma puede ser inhabilitado ajustando J1 en posición abierta.
Coverage / Couverture / Cubrimiento
BV-L1
Wall-to-Wall Lens (Standard)
Lentille mur à mur (Standard)
Lente de Pared a Pared (Normal)
50' × 60' (15.2 × 18.3m)
BV-L2
Corridor lens (optional)
Lentille couloir (optionnelle)
Lente Corredor (opcional)
120' × 10.5' (36.5 × 3.2m)
BV-L3
Curtain lens (optional)
Lentille rideau (optionnelle)
Lente Cortina (opcional)
50' × 4.4' (15.2 × 1.3m)
BV-L4
Pet Alley lens (optional)
Lentille passage pour animaux
(optionnelle)
Lente para animales (opcional)
50' × 60' (15.2 ×18.3m)
Models Modèles Modelos
BV-300D-GL Form ‘A’ alarm contact Contact d’alarme de forme ‘A Contacto de Alarma Forma ‘A
BV-301D-GL Form ‘A’ alarm contact & tamper switch Contact d’alarme de forme ‘A’ et interrupteur anti-sabotage Contacto de Alarma Forma ‘A’ e Interruptor de Sabotaje
BV-302D-GL Form ‘C’ alarm contact & tamper switch Contact d’alarme de forme ‘C’ et interrupteur anti-sabotage Contacto de Alarma Forma ‘C’ e Interruptor de Sabotaje
Mounting Height Chart
Tableau de la portée en fonction de la hauteur d’installation
Tabla de la Altura de Montaje
Height
Hauteur
Altura
Setting for Full Range
Ajustement pour rendement maximale
Ajusta para un Rango Total
BV-L1 BV-L2 BV-L3 BV-L4
10’(3m) *0.00 –0.25 0.00
8’(2.4m) +0.50 +0.25 0.00
7’(2.1m) +0.75 +0.25 0.00
6’(1.8m) +1.00 +0.50 0.00
5’(1.5m) 0.00
4’(1.2m) 0.00
Wiring
NOTE: This unit is UL-listed and should be
connected to a listed control unit or power
supply providing at least 4 hours of standby
power.
Câblage
NOTE : Ce dispositif est homologué UL et
doit être connecté à un panneau de contrôle
ou à une alimentation homologuée fournis-
sant au moins 4 heures d’alimentation de
secours.
Instalacn
NOTA: Esta unidad está homologada por UL
y debe ser conectada a un control o a un
suministro de energía homologado propor-
cionando al menos 4 horas de energía en reserva.
Mounting Brackets
Use the optional DM-W wall mount and
DM-C ceiling mount brackets to solve
placement problems. The brackets allow
for vertical and horizontal positioning of
the detector. The DM-C can be tilted up
or down and rotated through 90° to
obtain the best position for optimal cov-
erage. Contact your DSC distributor for
more information regarding these
mounting solutions.
Supports DM-C et DM-W
Utiliser les supports optionnels DM-W
pour installer le détecteur au mur, ou
DM-C pour le plafond afin de résoudre
certains problèmes d’emplacement. Les
supports offrent la possibilité d’un ajuste-
ment vertical et horizontal complet du
détecteur. Le DM-C peut pivoter de haut
en bas ou de gauche à droite sur 90°
pour obtenir la meilleure position pour
une couverture optimale de la région à
protéger. Contacter votre distributeur
DSC pour plus de renseignements.
Soportes de Montaje del
Detector DM-C y DM-W
Utilice los soportes de montaje opciona-
les DM-W Montaje en la Pared, y DM-C
Montaje en el Cielo Raso para resolver los
problemas de ubicación. Los soportes
permiten colocar el detector en forma
vertical y horizontal. El DM-C puede ser
inclinado hacia arriba o abajo y con rot-
ación 90° para obtener la mejor posición
para cobertura óptima. Contacte al distri-
buidor DSC para más información sobre
estas soluciones de montaje.
Limited Warranty
Digital Security Controls Ltd. warrants that for a period of five years from the date of purchase, the product shall be free of defects in
materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd.
shall, at its option, repair or replace the defective equipment upon return of the equipment to its repair depot. This warranty applies
only to defects in parts and workmanship and not to damage incurred in shipping or handling, or damage due to causes beyond the
control of Digital Security Controls Ltd. such as lightning, excessive voltage, mechanical shock, water damage, or damage arising out
of abuse, alteration or improper application of the equipment.
The foregoing warranty shall apply only to the original buyer, and is and shall be in lieu of any and all other warranties, whether
expressed or implied and of all other obligations or liabilities on the part of Digital Security Controls Ltd. Digital Security Controls Ltd.
neither assumes, nor authorizes any other person purporting to act on its behalf to modify or to change this warranty, nor to assume
for it any other warranty or liability concerning this product.
In no event shall Digital Security Controls Ltd. be liable for any direct, indirect or consequential damages, loss of anticipated profits,
loss of time or any other losses incurred by the buyer in connection with the purchase, installation or operation or failure of this prod-
uct.
Motion detectors can only detect motion within the designated areas as shown in their respective installation instructions. They cannot
discriminate between intruders and intended occupants. Motion detectors do not provide volumetric area protection. They have multi-
ple beams of detection and motion can only be detected in unobstructed areas covered by these beams. They cannot detect motion
which occurs behind walls, ceilings, floor, closed doors, glass partitions, glass doors or windows. Any type of tampering whether
intentional or unintentional such as masking, painting, or spraying of any material on the lenses, mirrors, windows or any other part
of the detection system will impair its proper operation.
Passive infrared motion detectors operate by sensing changes in temperature. However their effectiveness can be reduced when the
ambient temperature rises near or above body temperature or if there are intentional or unintentional sources of heat in or near the
detection area. Some of these heat sources could be heaters, radiators, stoves, barbeques, fireplaces, sunlight, steam vents, lighting
and so on.
WARNING: Digital Security Controls Ltd. recommends that the entire system be completely tested on a regular basis. However,
despite frequent testing, and due to, but not limited to, criminal tampering or electrical disruption, it is possible for this product to fail
to perform as expected.
IMPORTANT INFORMATION: Changes or modifications not expressly approved by Digital Security Controls Ltd. could void the
user’s authority to operate this equipment.
Garantie limitée
Digital Security Controls Ltée., pendant une période de douze mois à partir de la date d’achat, garantit le produit contre toute fectuosité
matérielle et d’assemblage dans des conditions normales d’utilisation. Dans l’application de cette garantie, Digital Security Controls Ltée.
va, lorsqu’elle le juge opportun, en cas de problèmes de fonctionnement,parer ou remplacer les équipements défectueux dès leur retour
à sonpôt de réparation. Cette garantie s’applique seulement aux éléments défectueux et à la main-d’oeuvre, et non aux dommages
causés lors de l’expédition ou de la manipulation, ni aux dommages dont les causes passent le contrôle de Digital Security Controls Ltée.
telles que la foudre, les surtensions, les chocs mécaniques, les déts d’eau ou tout dommage provenant d’abus, de modifications ou de
mauvaises utilisations de l’équipement.
La garantie susdite n’est valide que pour l’acheteur original et n’est et ne sera que la seule des garanties valables, qu’elle ait éexprimée
ou implicite, remplaçant toute autre obligation ou responsabilité de la part de Digital Security Controls Ltée. La présente garantie contient
la garantie au complet. Digital Security Controls Ltée. n’autorise aucune autre personne à agir en son nom pour modifier ou changer la
présente garantie et n’en assume pas la responsabilité, ni a à assumer en son nom toute autre garantie ou responsabilité concernant le
présent produit.
En aucun cas, Digital Security Controls Ltée. ne pourra être tenue responsable des conséquences directes ou indirectes de dommages rela-
tivement à la perte de profits prévus, à la perte de temps ou à toute autre perte subie par l’acheteur en rapport avec l’achat, l’installation
et le fonctionnement ou la défaillance du présent produit.
Les détecteurs de mouvement ne peuvent tecter le mouvement que dans les zones désignées, conformément aux instructions d’installa-
tion. Ils ne peuvent pas distinguer entre intrus et occupants. Les détecteurs de mouvement ne fournissent pas de protection de zone vol-
umétrique. Ils ont de multiples rayons de détection et les mouvements ne peuvent être détectés que dans des zones non obstruées et
couvertes par ces rayons. Ils ne peuvent détecter les mouvements qui se produisent derrière les murs, plafonds, sol, portes fermées, cloi-
sons vitrées, portes vitrées ou fenêtres. Tout type de problème qu’il soit intentionnel ou non tels camouflage, peinture ou vaporisation de
matériel sur les lentilles, miroirs, fenêtres ou toute autre partie du système de tection l’emchera de son fonctionner normalement.
Les détecteurs de mouvement à infrarouge passif fonctionnent entectant les changements de température. Cependant leur fonctionne-
ment peut être inhibé quand la temrature ambiante s’approche ou dépasse la température du corps ou s’il y a des sources de chaleur
intentionnelles ou non intentionnelles dans la zone de détection ou à côté de celle-ci. Quelques-unes de ces sources de chaleur peuvent
être chauffages, radiateurs, fours, barbecues, cheminées, lumre du soleil, éclairages, etc.
AVERTISSEMENT : Digital Security Controls Ltée. recommande que le système soit régulièrement soumis à un essai complet. Cepen-
dant, en dépit d’essais réguliers et à cause d’interventions criminelles, pannes de courant ou autres, il est possible que le fonctionnement
du produit ne soit pas conforme aux spécifications.
INFORMATION IMPORTANTE : Tout changement ou modification qui n’est pas expressément approuvé par Digital Security Controls
Ltd. pourrait annuler le droit d’usage de cet équipement.
Garantía Limitada
Digital Security Controls Ltd. garantiza que por un período de 5 os desde la fecha de adquisición, el producto estará libre de defectos en
materiales y mano de obra bajo condiciones de uso normal y que, en cumplimiento de cualquier violación de dicha garantía, Digital Secu-
rity Controls Ltd., podrá, a su opción, reparar o reemplazar el equipo defectuoso al recibo del equipo en su local de servicio. Esta garantía se
aplica solamente a defectos en componentes y mano de obra y no a los dos que puedan haberse presentado durante el transporte y
manipulación o a dos debidos a causas fuera del control de Digital Security Controls Ltd. tales como rayos, voltaje excesivo, sacudidas
mecánicas, daños por agua, o dos resultantes del abuso, alteración o aplicación inadecuada del equipo.
La garantía anterior se aplicará solamente al comprador original y sustituye a cualquier otra garantía, p2-ya sea explícita o implícita, y todas
las otras obligaciones y responsabilidades por parte de Digital Security Controls Ltd. Esta garantía contiene la garantía total. Digital Security
Controls Ltd. no se compromete, ni autoriza a ninguna otra persona que pretenda actuar a su nombre, a modificar o cambiar esta garantía
ni a asumir ninguna otra garantía o responsabilidad con respecto a este producto.
En ningún caso, Digital Security Controls Ltd. será responsable de cualquier daño o perjuicio directo, indirecto o consecuente, pérdidas de
utilidades esperadas, pérdidas de tiempo o cualquier otra pérdida incurrida por el comprador con relación a la adquisición, instalación,
operación o fallo de este producto.
Los detectores de movimiento solamente pueden detectar movimiento dentro de las áreas designadas como se muestra en las respectivas
instrucciones de instalación. Los detectores de movimiento no pueden discriminar entre intrusos y los que habitan el local o residencia. Los
detectores de movimiento no proporcionan un área de protección volumétrica. Estos poseen múltiples rayos de detección y el movimiento
solamente puede ser detectado en áreas no obstruidas que están cubiertas por estos rayos. Ellos no pueden detectar movimiento que ocurre
detrás de las paredes, cielo rasos, pisos, puertas cerradas, separaciones de vidrio, puertas o ventanas de vidrio. Cualquier clase de sabotaje
ya sea intencional o sin intención tales como encubrimiento, pintando o regando cualquier tipo de material en los lentes, espejos, ventanas
o cualquier otra parte del sistema de detección perjudicará su correcta operación.
Los detectores de movimiento pasivos infrarrojos operan detectando cambios en la temperatura. Sin embargo su efectividad puede ser redu-
cida cuando la temperatura del ambiente aumenta o disminuye de la temperatura del cuerpo o si hay orígenes intencionales o sin intención
de calor en o cerca del área de detección. Algunos de los orígenes de calor pueden ser calentadores, radiadores, estufas, asadores, chime-
neas, luz solar, ventiladores de vapor, alumbrado y así sucesivamente.
ADVERTENCIA: Digital Security Controls Ltd. recomienda que el sistema sea probado en su integridad con la debida regularidad. Sin
embargo, a pesar de pruebas frecuentes y debido a interferencia criminal o cortes eléctricos, pero no sólo limitado a ellos, es posible que
este producto deje de operar en la forma esperada.
INFORMACIÓN IMPORTANTE: Los cambios o modificaciones no aprobadas expresamente por Digital Security Controls Ltd., pueden cancelar
la autoridad del usuario para operar este equipo. www.dscgrp.com
Specifications Spécifications Especificaciones
Operating voltage Tension d’opération Voltaje de Operación 9.5VDC DC CC CC-14.5V / 9.5V -14.5V
Supply voltage ripple Ondulation de la tension d’alim. Tensión de ondulación del suministro de voltaje 3.0V pp @ 12VDC / 3.0V pp @ 12VCC
Standby current Courant au repos Corriente de espera (Nominal) 15mA
Current in alarm Courant en alarme Corriente en alarma (Nominal) 18mA
Contact rating Courant nominal des contacts Porcentaje de contactos (alarma y sabotaje) 100mA @ 24V
DC CC
/
100mA @24V
Alarm contact resistor in common Résistance de contact d’alarme de la ligne commune Resistencia de contactos de alarma en común 100.25W
Operating temp. T Température d’opération emperatura para Operar 0°C-50°C (32°F-122°F)
Storage temp. T Température d’entreposage emperatura para Guardar -40°C-60°C (40°F-140°F)
Operating humidity Humidité en opération Humedad para Operar 5-95% RH non cond. / d’HR non-cond. / HR no condensada *
Storage humidity Humidité en entreposage Humedad para Guardar up to 99% RH non cond. / d’HR non-cond. / HR no condensada
RF immunity Immunité aux radiofréquences Inmunidad RF 10 V/m with 80% AM from 80MHz-1GHz **
Static immunity Immunité à l’électricité statique Inmunidad de Estática 8kV contact, 15kV air / / 8kV contacto, 15kV aire
Transient immunity Immunité aux courants transitoires Inmunidad Transitoria 2.4kV @ 1.2 joules
Walk detection speed Vitesse de détection de marche Velocidad de detección de paso 0.5-10'/s (0.15-3m/s)
White light immunity Immunité à la lumière blanche Immunidad a luz blanca 20,000Lux@device / détecteur / en el detector
Coverage angle (BV-L1) Couverture angulaire (BV-L1) Angulo de Cobertura (BV-L1) 90° min.
Vertical adjustments Réglage vertical Ajuste Vertical +5° to -10°
Mounting heights Hauteurs d’installation Altura del montaje 6-10.5'/1.8-3.2m (nominal 7.5'/2.3m) BV-L1, L2, L3
4-5'/1.2-1.5m BV-L4


Product specificaties

Merk: DSC
Categorie: Bewegingsmelders
Model: BV-300D
Kleur van het product: Wit
LED-indicatoren: Alarm
Plaatsing: Binnen
Connectiviteitstechnologie: Bedraad
Type stroombron: DC
Alarm functie: Ja
Type beeldsensor: Passieve infraroodsensor (PIR)
Temperatuur bij opslag: -40 - 60 °C
Luchtvochtigheid bij opslag: 0 - 99 procent
Bedrijfstemperatuur (T-T): 0 - 49 °C
Relatieve vochtigheid in bedrijf (V-V): 5 - 95 procent
Detectie hoek: 90 °
Installatie hoogte (max): 2.3 m
Stroom in standby: 15 mA
Statische stroom: 3 mA
Huisdierimmuniteit (max): 27.3 kg

Heb je hulp nodig?

Als je hulp nodig hebt met DSC BV-300D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Bewegingsmelders DSC

DSC

DSC BV-300D Handleiding

19 November 2022

Handleiding Bewegingsmelders

Nieuwste handleidingen voor Bewegingsmelders