1. INTRODUCTION
1.1 SCOPE
This Lever Action Barrel Pump is a hand operated heavy duty pump designed to transfer oil
based fluids, heating oils, motor oils, diesel oil, kerosene, heavy & light oils
The pump comes complete with self adjusting telescopic suction tube, curved metal spout, and
1Β½" & 2" bung nut.
2. HEALTH AND SAFETY INFORMATION
2.1 GENERAL SAFETY INFORMATION
To ensure safe and efficient operation, it is essential to read and follow each of these warnings
and precautions.
1. Improper use or installation of this product can cause serious bodily injury or death.
2. Do NOT smoke near pump or use pump near an open flame. Fire could result.
3. When pumping flammable liquids, all equipment must be grounded to prevent the
accumulation of static electricity which may ignite vapours or gases.
4. The pump and containers should be connected using bonding clamps or clips and a
conductive wire no smaller than 12 gauge. A secure and positive metal-to-metal contact must
be made. The other end of the wire should be attached to a good ground, such as a steel
building column or water pipe.
Warning: Leave handle in upright position when not in use.
1.2 SPECIFICATION
Stock Noβs. ............................................................................................................................... 47808
Part Noβs. ................................................................................................................................. BP/G
Barrel size ..................................................................................................... 1Β½" & 2" bung adaptor
Delivery rate ....................................................................................... up to 300ml(10oz. per stroke)
Non return seal.......................................................................................................................... NBR
Wetted components................................................................ Steel, Aluminium, Zinc, Brass & NBR.
Recommended use: ..
Oil base fluids, heating oils, motor oils, diesel oil, kerosene, heavy & light oils.
Do not use: ............... Water based fluids, solvents, acid, antifreeze or fluids that cause corrosion.

- 3 -
3. TECHNICAL DESCRIPTION
4. ASSEMBLY
4.1 ASSEMBLY
1. Screw the suction tube assembly into the bung nut . Tighten the connection securely to ξξξξ
eliminate any air leaks.
2. Screw the delivery spout nut (part of the spout) onto the pump head. Tighten securely to ξξξ
eliminate any possibility of leakage.
3. Extend the telescopic suction pipe little longer than the height of the drum.ξξξξ
4. Screw the pump into the drumβs bung. Tighten the pump assembly securely by grasping the
pump body and rotating.ξξξ
5. Pull the plunger rod of piston sub assembly up and attach the lever handle to the piston ξξξ
rod using the pivot pin and retainer clip .ξξξ
ξξξ Pivot Pin & retainer clip.
ξξξ Plunger rod.
ξξξ Lever handle.
ξξξ Delivery spout
ξξξ Compression nut.
ξξξ Spout nut.
ξξξ Pump head.
ξξξ Rubber grip.
ξξξ Pump body.
ξξξξ Bung nut.
ξξξξ Suction tube assembly.
3.1 IDENTIFICATION
ξξξ
ξξξ
ξξξ
ξξξ
ξξξ
ξξξ
ξξξξ
ξξξξ
ξξξ
ξξξ
ξξξ

5. OPERATION
5.1 OPERATION
Now the pump is ready, start operating the pump by giving quick strokes to the lever handle.
NOTE:
1. Apply thread sealant to the threads of the suction tube assembly before attaching it to the
bung nut. Do not use undue force when tightening.
2. Ensure rubber gasket is positioned properly in spout nut before attaching the Delivery ξξξ
spout .ξξξ
3. The telescopic suction tube will automatically adjust to the proper position.
4. Do not tighten the pump by holding the lever handle .ξξξ
5. Ensure that the retainer clip is bent properly so as eliminate possibility of pivot pin coming out
while using the pump.
NOTE: The pump is constructed using plated steel components. It should never be used to
transfer fluids that may cause the pump to rust. Certain fluids have a tendency to build a coating
on the surface when dry, it is recommended to leave the lever handle in upright position when not
in use.
5.2 PRIME THE PUMP
If the pumps fails to operate, it may be necessary to prime.
Turn the delivery spout upward.
Pour a few drops of the fluid being dispensed into the spout.
Start the pump by moving the lever with several quick strokes.
If the pump still fails to start:
Remove the pump from the drum and ensure the Suction tube is extended enough to reach the
bottom of the drum.
Draper Tools Limited, Hursley Road,
Chandler's Ford, Eastleigh, Hampshire. SO53 1YF. U.K.
Helpline: (023) 8049 4344
Sales Desk: (023) 8049 4333
Internet: drapertools.com
E-mail: sales@drapertools.com
General Enquiries: (023) 8026 6355
Service/Warranty Repair Agent:
For aftersales servicing or warranty repairs, please contact the
Draper Tools Helpline for details of an agent in your local area.
Β©Published by Draper Tools Limited.
No part of this publication may be reproduced, stored in a retrieval system or transmitted in any form or by any means,
electronic, mechanical photocopying, recording or otherwise without prior permission in writing from Draper Tools Ltd.
CONTACTS
YOUR DRAPER STOCKIST
SRMC0218
Product specificaties
Merk: | Draper |
Categorie: | Pomp |
Model: | 47808 |
Heb je hulp nodig?
Als je hulp nodig hebt met Draper 47808 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Pomp Draper

3 Juni 2025

2 Juni 2025

2 Juni 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025

30 Mei 2025
Handleiding Pomp
- Pomp Sun Joe
- Pomp Plantiflor
- Pomp Bartscher
- Pomp Vonroc
- Pomp B-Air
- Pomp Zodiac
- Pomp Westfalia
- Pomp Superior Pump
- Pomp OSIP
- Pomp Milwaukee
- Pomp Powerfix
- Pomp Hyundai
- Pomp Generac
- Pomp Makita
- Pomp Park Tool
Nieuwste handleidingen voor Pomp

4 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025

1 April 2025