Dormakaba DRS Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Dormakaba DRS (11 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 44 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/11
DRS Rail System
For 2-1/2”, 3-5/8”, 4”, 6”, and 10” DRS Rail Systems
Installation instructions
934806 – 04-2021
| | EN
2DRS Rail Systems 04-2021934806
dormakaba DRS Rail Systems Installation Instructions
Table of Contents
Table of contents
1  Technical specifications 3
1.1 Overview 3
1.1.1 General information 3
1.1.2 Intended use 3
1.1.3 Glass requirements/fittings/mounting 3
1.1.4 Requirements for glass panel 3
1.1.5 Safety instructions 3
1.1.6 Symbols used - Safety/Installation 3
1.1.7 Maintenance, care, repair 3
1.1.8 Disposal 3
1.2 Tempered laminate glass (TLG) and
adhesive specifications 4
1.3 Tools recommended 4
1.4 Preparing the glass and rails 4
1.5 System setup 5
2 Installation instructions 6
2.1 Install rails onto glass panel 6
2.2 Install glass door panels and rails into frame:
For use with: RTS88 header and 8852 bottom
pivot 7
2.3 Install glass door panels and rails into frame:
For use with: PT21 (walking beam pivot) and
BTS80 with 7422 bottom arm 8
2.4 Install glass door panels and rails into frame:
For use with: PT21 (walking beam pivot) and
BTS80 with 355.1 insert 9
2.5 Install rail covers and end caps 10
dormakaba DRS Rail Systems Installation Instructions
934806 04-2021DRS Rail Systems 3
Technical specifications
1  Technical specifications
1.1 Overview
These instructions are for installation of the DRS Rail
System for the following mounting and style versions:
1. Glass mounting
1.1.1 General information
• dormakaba requires use of tempered laminated or
tempered monolithic glass.
• dormakaba glass hardware is not suitable for harsh
environment; for example, applications where
chemicals (e.g. chlorine) are used such as indoor
swimming pools, saunas, or salt-water pools.
• Do not swing doors with excessive force. Install
limiting stop to prevent door from opening too far.
• If an impenetrable door panel material is chosen to
be used for additional security purposes, then the
two outermost bolts on each rail can be also be
reversed, to hinder attempted disassembly after
installation.
1.1.2 Intended use
• For pivoting doors in indoor or covered areas only.
• For automatic or manual slow opening and closing.
1.1.3 Glass requirements/fittings/mounting
• The substructure/wall must be able to bear
permanent loads, be level (max. tolerance: 1/16”
[2] per 39” [1m]).
• Fasteners must be sufficiently dimensioned for the
substructure/wall and weight of the door.
• When adjusting glass components, always stick to
the required clearance for the respective hardware.
Adjust clearance so glass does not come in contact
with any hard surfaces such as glass, metal or
concrete.
• Do not use excessive force when installing the glass
(avoid over tightening screws.)
1.1.4 Requirements for glass panel
• dormakaba requires use of fully tempered glass,
which complies with ASTM C 1036 and ASTM C
1048. Secondary heat soaking processes are
optional but not required. This applies to both
tempered monolithic and tempered laminated
glass.
• Clamping area must be flat and uncoated (no
self-cleaning coating!)
• Never use glass with conchoidal fractures and/or
damaged edges.
1.1.5 Safety instructions
• Installation requires two people.
• Always wear protective clothing.
• Only properly qualified and specially trained staff is
authorized to mount dormakaba glass hardware.
• Due to crushing hazards and possible injury caused
by breakage of glass during mounting,
corresponding protective clothing (especially gloves
and protective goggles) is required.
• Never clamp metal fitting hardware directly to
glass surface.
1.1.6 Symbols used - Safety/Installation
CAUTION
Mounting components must meet the
requirements of substructure/wall and door
weight. Please read the technical information
for fittings.
WARNING
Risk of breaking glass. When installing the
door, support the door panel with a block of
wood or similar object.
1.1.7 Maintenance, care, repair
• Immediately replace damaged parts.
• Always use original dormakaba parts.
• Clean clamping area with alcohol-based standard
commercial cleaning agent before mounting the
glass hardware.
• Use a damp cloth for occasional cleaning.
• Always use silicone - and oil-free cleaners (e.g.
acetone).
• Check glass hardware at regular intervals for
proper positioning, smooth operation and correct
adjustment.
• High traffic door systems require inspection by
properly qualified staff (specialized companies or
installation firms.)
• Function of fittings is recommended to be
inspected every 500,000 movements by a specialist.
1.1.8 Disposal
Disposal in accordance with local, state and national
regulations.


Product specificaties

Merk: Dormakaba
Categorie: Niet gecategoriseerd
Model: DRS

Heb je hulp nodig?

Als je hulp nodig hebt met Dormakaba DRS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Dormakaba

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd