Delonghi Pinguino PAC C100 Handleiding

Delonghi Airco Pinguino PAC C100

Lees hieronder de 📖 handleiding in het Nederlandse voor Delonghi Pinguino PAC C100 (14 pagina's) in de categorie Airco. Deze handleiding was nuttig voor 68 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/14
4
IMPORTANT SAFEGUARDS
DESCRIPTION
1air outlet grille
2 control panel
3 castors
4 handles
5 filter
6 air intake grille
7 air exhaust hose housing
8 drainage hose
9 power cable
10 wall flange
11 suction pads
12 air exhaust hose
13 window outlet
14 castor locks
15 remote control
16 window bracket with locking pin
• Use this appliance only as described in this instruction manual.
As with any electrical appliance, the instructions aim to cover as many eventualities as possi-
ble. Caution and common sense should be used when operating and installing this air condi-
tioner.
• This appliance has been manufactured to cool and dehumidify domestic environments and
should not be used for other purposes.
• It is dangerous to alter or modify the unit's characteristics in any way.
• The appliance must be installed in line with the relevant national legislation.
• Should repairs be necessary, contact the nearest authorized Repair Service Center. Unautho-
rized servicing can be dangerous.
• This appliance is to be used by adults only; keep away from children.
• In the case that the power cord becomes damaged, to protect against fire, it must be substituted
only by specialized personnel authorized by the manufacturer.
• Always ensure the appliance is grounded. If you have any doubts check with a qualified elec-
trician.
• We strongly discourage the use of an extension cord due to potential safety hazards.
• Before cleaning or maintenance operations, always unplug the unit from the outlet.
• Do not pull on or place strain on the power cord when moving the appliance.
• The appliance should not be installed where the atmosphere may contain combustible gases,
oil or sulphur, or near heat sources.
• Do not rest hot or heavy objects on the appliance.
• Clean the filters at least once a week.
• Avoid using heaters near the unit.
• The unit should be transported in a vertical position. If this is not possible secure the unit at an
angle, do not lie it horizontally.
• Before transporting the unit, drain the unit. After transportation, wait at least 1 hour before switch-
ing the unit on.
• The packaging materials can be recycled. It is, therefore, recommended to place them in the
special containers for differentiated waste collection.
• This appliance is fitted with a special safety device. When the compressor switches off, this
device prevents it from switching on again for at least 3 minutes.
SAVE THESE INSTRUCTIONS
THIS PRODUCT IS FOR HOUSEHOLD ONLY
5
The instructions below will enable you to prepare your air conditioner for operation as efficiently
as possible.
Before use, make sure the air intake and outlet grilles are unobstructed.
AIR-CONDITIONING WITHOUT INSTALLATION
Just a few simple steps and your comfort is
ensured with your air conditioner:
• Fit the air exhaust hose in the housing
at the back of the appliance.
Insert it as shown in figure A.
7
12
For optimum results:
• If you have a sash window, place the win-
dow bracket on the window sill, extend
the bracket fully within the window frame,
secure the bracket by using the locking pin
then lower the window onto the bracket.
Insert the window outlet of the exhaust
hose into the slot, then connect the hose
to the air conditioner (fig. B ).
12
13
16
Installing Your Portable
Air-Conditioner
Keep the air hose as short and free of
curves as possible to avoid constrictions.
ELECTRICAL CONNECTIONS
Before plugging the appliance into the electrical socket, check that:
• The power supply corresponds to the value indicated on the rating plate on the back of the appliance;
• The socket and electrical circuit are adequate for the appliance;
• The socket matches the plug. If this is not the case, have the plug replaced;
• The socket is adequately grounded.
Failure to follow these important safety instructions absolves the manufacturer of all liability.
The power cable must be replaced by a qualified professional only.
B
Thanks to the locking pin, it’s possible to use
the window bracket also for sliding windows.
Position the hole of the bracket so to allow a
correct installation of the exhaust hose.
French window
• Open the French window slightly and posi-
tion the window outlet as shown in
figure C.
13
A
D
• Use the suction pads provided to hold
the two parts of the window together (fig. D).
11
C
134
5,27 in.
in the window
pane
in the wall: for
optimum results,
insulate the sec-
tion of the wall with
suitable insulating
material.
in the wood-
en kickboard
of a French
window
F
Prep ar i n g for u se
MAX100 cm
MAX 39 inches
MIN 35 cm
MAX 14 inches
SEMI-PERMANENT INSTALLATION
If required, your appliance can also be
installed semi-permanently (Fig. E).
Proceed as follows:
• Drill a hole ø 134 mm (5.27 in.) in an out-
side wall or through a window pane.
Respect the dimensions and height of the
hole given in figure F and G.
• Fit the wall flange into the hole.
• Fit the air exhaust hose in the housing
at the back of the appliance. (fig. A page
5).
• Fit the end of the air exhaust hose to
the wall flange as shown in fig. G.
10
12
12
10
G
NOTE: When installing the air conditioner
semi-permanently, you should leave a door
slightly open (as little as 1/2 - in 1 cm ) to guar-
antee correct ventilation.
6
30 cm
12 inches
30 cm
12 inches E
Keep the air hose as short and free of
curves as possible to avoid constrictions.
When the hose ( is not fitted, the drilled12)
hole can be closed with the flange cap (10).


Product specificaties

Merk: Delonghi
Categorie: Airco
Model: Pinguino PAC C100

Heb je hulp nodig?

Als je hulp nodig hebt met Delonghi Pinguino PAC C100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Airco Delonghi

Handleiding Airco

Nieuwste handleidingen voor Airco