Bekijk gratis de handleiding van Daytronic 10A17-2 (4 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 25 mensen en kreeg gemiddeld 4.8 sterren uit 8 reviews. Heb je een vraag over Daytronic 10A17-2 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/4

SYSTEM10
ANALOGINPUTCARDS
1.E.2.10A17-2
1GENERALDESCRIPTIONANDSPECIFICATIONS
The Model 10A17-2 is designed for high-accuracy temperature measurement using
platinum
Resistance Temperature Detectors (RTD's) and requiring high input isola-
tion.
Precision constant-current excitation is provided for two independent sensor
channels, which may be intermixed as required. Each input is transformer-isolated, so
that sensor-to-sensor common-mode voltages as high as 1500 V-DC can be accom-
modated without damaging the instrument or perceptibly affecting measurement
accuracy. Four-wire cabling, with maximum excitation of one milliampere and 0.004%
per ohm leadwire resistance rejection, eliminates common self-heating and cable-
loading errors. This conditioner is particularly useful in the utilities industry.
ADDITIONAL10A17-2 SPECIFICATIONS
RTD Types: Platinum; DIN (European) standard with “ice-point” resistance of 50, 100,
or 200 ohms, or American standard with “ice-point” of 100 ohms
Range and Resolution: See Table 1, below; automatically selected—on an individual
channel basis—when the channel is configured; for System 10 channel “type” codes
assigned to 10A17-2 data channels, see Table 1; for
high RTD resolution, using a
specially modified 10A17-2 card, see Section 3.b, below
Linearization: Internal digital linearization; maximum error: ±0.1°C (±0.2°F)
Excitation (per channel): Nominal 5 V-DC; 1 mA, maximum
Amplifier (per channel):
Common-Mode Range:±1500 V operating and without instrument damage
Common-Mode Rejection Ration: DC: -150 dB; at 60 Hz: -160 dB; at 1 kHz and 3
kHz; infinite
Leadwire Resistance Rejection (4-wire only): 0.004% per ohm
Offset: Initial: ±0.01% of full scale; vs. Temperature: ±10 ppm/°C; vs. Time: ±10
ppm/month
Gain Accuracy: ±0.02% of full scale
Gain Stability: vs. Temperature: ±50 ppm/°C; vs. Time: ±50 ppm/month
Filter (per channel): 3-pole modified Butterworth; 3 dB down at 2 Hz; 60 dB down at
30 Hz
Step-Response Settling Time (Full-Scale Output):
To 1% of final value: 260 msec
To 0.1% of final value: 500 msec
To 0.02% of final value: 600 msec
Total System Accuracy(typical, including Model 10A17-2 and system data collec-
tion and processing): see Table 1, below
Auxiliary Outputs: Filtered outputs available on mainframe wire-wrap pins
MODEL10A17-2
DUALHIGH-VOLTAGEISOLATIONRTD
C
ONDITIONERCARD
GENERALDESCRIPTIONANDSPECIFICATIONS10A17-2.1
Product specificaties
| Merk: | Daytronic |
| Categorie: | Niet gecategoriseerd |
| Model: | 10A17-2 |
Heb je hulp nodig?
Als je hulp nodig hebt met Daytronic 10A17-2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Daytronic
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
25 Januari 2024
Handleiding Niet gecategoriseerd
Nieuwste handleidingen voor Niet gecategoriseerd
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026
25 Augustus 2026