CyberPower P704URC1 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower P704URC1 (1 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 30 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/1
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberP erSystems.com for more information regarding: ow
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberP erSystems.com/supportow
Toll-Free: 1-877-297- 3769
Š 2023 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
FEATURES
1. ON/OFF Reset Control Switch and Circuit Breaker
Controls power to all outlets. The switch is also a 15 A
breaker. When an overload occurs, it will automatically
switch o. To resume operation, ensure the overload
condition is removed and reset the surge protector by
switching the unit ON.
2. Protected LED Indicator
Illuminated when the surge protection feature is
working properly.
3. Grounded LED Indicator
Illuminated when the surge protector is properly
grounded.
4. USB-A Charging Ports (2)
5. Standard Grounded Outlets (7)
6. Power Cord
TROUBLESHOOTING
If the ON/OFF is switched OFF, the 15 Amp circuit breaker may have tripped.
Examine your connected equipment and remove the device that is overloading
the circuit. Then, turn the ON/OFF switch back to RESET.
If the grounded indicator does not light when you plug in the surge protector,
still does not light, return the product to the retailer for assistance. If the surge
protector appears to be working properly, your outlets may not be properly
grounded and need to be repaired by a professional electrician.
If t ed i t lig e s C li s ahe protect ndicat oor d es no ht, h t urge rot p ector’s A ne re
no on er or l g p s prot te ro urge. Theec d f m s urge rotect ma have rec v a y ei ed
pow ur k eyer s ge or spi e b ond its spe ied limits t aded t e pc hat overlo h rotection
ci it y d de acti d rcu r an ren r ned it i ve. T ur rotect rotectehe s ge p or has p y r ou
c ect u a d, u w rotec ains uture urges onn ed eq ipm t en s designe b t it ill not p t ag t f s
an k . re ced.d spi es It s ld be hou pla
YOUR ULTIMATE ALLY IN POWER
Cyber P er Systems (USA), Inc.ow
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberP erSystems.comow
SPECIFICATIONS
Model Number: P704URC1
Outlets: Standard Grounded Outlets (7),
USB Charging Ports (2)
P er Cord Length: 4 ftow
Surge Protection: 2000 Joules
USB-A Charging Output: 2.4 A Shared
Electrical Rating: 125 V/15 A/60 Hz/1875 W
UL Clamping Voltage: UL1449 4th/600 V
(L-N, L-G, N-G)
Maximum Peak Current: 60000A
3 AC Lines Protected: L-N: 30000 A; L-G: 15000 A;
N-G: 15000A
Response Time: Less than 1 nanosecond
Circuit Breaker: Resettable 15 Amp
i WARNING: Th ris p oduct can expose you to che cmicals in ludi nol n eg bisph A PA) (B
a snd tyrene c (ABS), whi h is known to the State of California to cause reprodu tic ve
ha nrm a d cancer. For more f in orm tioa n, go to www.P65War .ca.gov.nings
CONFORMANCE APPROVALS
Th eis d vice co w h Par 5 o FC u . mplies it t 1 f the C R les
Ope tira on is subje t c to h t e llfo owin wg t o nditico ons: (1) this
de cvi e may not cau har u nterference, hse mf l i and (2) t is device must
a e an nt fercc pt y i er enc rec ved,e ei in u n ntcl di g i erferenc ha ay e t t m
c de re o ra . au unse si d pe tion
Th equis ipmen a een testt h s b ed d d an foun to co wmply ith h s t e limit
f a s aor Cla s B digit l device, t pur ansu t o Pa 5 o hrt 1 f t e FCC Rules.
Th e are to roes limits designed p vide reasonable protec against tion
har u nterferencemf l i in a reside tall ti . n nstial i a on Th equis ipment
generates, uses, an n ra atd ca di e ra rdio f equenc ner not y e gy and, if
ins n u ntalled a d sed i accor ncda e itw h h nst s, a t e i ru oncti m y cause
har u nterference t ra o cmf l i o di omm ic tioun a ns.
H ver, herowe t e is no ua g rant a nterferencee th t i e w o occur ill n t
in a r l nsta a u pa ticu ar i ll tion. If this eq ipme se mfn e ut do s ca har ul
interference to ra o or t edi el vision rec , h c deter ned eption whic an be mi
c rec h t ferencor t t e in er e by one o mo of tr re he llfo owin res: g measu
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
K01-E000093-00
7-OUTLET
SURGE PROTECTOR
(7 AC & 2 USB PORTS)
P704URC1
1
2
3
4
5
6


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: P704URC1

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower P704URC1 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd