CyberPower HT705GR Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor CyberPower HT705GR (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 23 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
FEATURES
1. Green Rocker Power Switch
2. Surge-Protected Indicator LED
Illuminated when the surge-protection feature is working
properly
3. Ground Indicator LED
Illuminated when the grounded feature is working properly
4. Energy-Saving Indicator LED
Illuminated only during the Power-Saving Measurement
Initialization
5. Small-Input Jack
6. Sensor Plug
7. Always-On Outlets
These outlets receive continuous power
8. Energy-Saving Outlets
See operation section above
9. IR Sensor
Detects IR signals from your remote
10. IR Sensor Button
Sets the energy saving timer
11. 2 Wide-Spaced Outlets
7-OUTLET TIER 2
ADVANCED POWER STRIP
HT705GR
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
ALWAYS ON / CABLE, DVR ENERGY SAVING / TV
PROTECTED
GROUNDED
ENERGY SAVING
1
7
2
3
11
11
10
5
4
6
9
8
SPECIFICATIONS
Model Number:
Outlets:
Surge Protection:
Electrical Rating:
UL Clamping Voltage:
Maximum Peak Current:
3 AC Lines Protected:
Response Time:
Attenuation:
EMI/RFI Filtration:
HT705GR
2 Always-On Outlets
5 Energy-Saving Outlets
(5 Standard Outlets and
2 Transformer spaced outlets )
1,500 Joules
125 V / 15 A / 1875 W
UL 1449 4th
500 V (H-N, H-G, N-G)
60,000 A
H-N: 30,000 A,
H-G: 15,000 A,
N-G: 15,000 A
(The maximum surge possible on
household wiring is 6,000 volts)
Less than 1 nanosecond
Up to 43 dB
150 kHz to 100 MHz
IR Detection Range/Degree: 16.4 ft./60
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK: Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal protection that will disconnect the surge protective component at the end of its useful life,
but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
Š 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
TROUBLESHOOTING
PROBLEM TO CHECK
The Always-On outlets are not
receiving the power
• Ensure the plug connections are
secure and the power switch is set to
the on/reset position.
The HT705GR does not power o the
connected equipment in standby mode.
• Ensure the equipment is plugged into
the Energy-Saving outlets, not into
the Always On outlets.
• The HT705GR has not detected the
connected equipment in standby.
Please press the IR sensor button for
more than 10 seconds and release to
enter into the setting mode. When
switching surge o/on again assure
all connected equipment are placed in
power-o or standby mode.
The IR Sensor is not operating. • Turn o the HT705GR power, re-plug
the IR Sensor cable, then turn on the
HT705GR
The IR Sensor flashes frequently during
normal operation.
• It may be radio frequency interfer-
ence. Check for other devices that
may be causing interference in the
area.
• Move the IR Sensor to another loca-
tion that is within line of sight and
normal operation range of connected
equipment remote controls.
The surge protected LED of the
HT705GR is on, but my IR Sensor LED
does not work (when the IR Sensor is
plugged in and powered on).
• Ensure the IR Sensor cable is safely
and securely connected to the
HT705GR, and;
• Press the IR Sensor button, the
Energy-Saving outlet will turn on.
The HT705GR is not working / the
protected LED is not illuminated.
• Remove all the connected equipment
and power cord from the wall outlet.
Reset surge protector by pressing and
hold the IR Sensor button for more
than 10 seconds, then release.
• If the grounded indicator does not
light when you plug in the surge pro-
tector, move the surge protector to
a dierent grounded three-prong AC
outlet. If the surge protector proves
to be working properly, your outlets
may not be properly grounded and
need to be repaired by a professional
electrician.
The connected equipment turned o
after 1 hour.
• The default setting for the energy
saving time is 1 hour.
• If you want to change the energy
saving time, please check the quick
start guide section to change default
energy saving time from 1 or 2 hours.
YOUR ULTIMATE ALLY IN POWER
QUICK START GUIDE
1. Connections:
Turn power switch to OFF. Plug surge protector into wall.
Plug powered-down electronic devices in to appropriate
outlets. Connect infrared (IR) sensor to surge protector into
small input jack. Place glossy side of IR sensor in sightline of
remotes. Turn power switch to ON using green rocker switch.
LED indicators (Protected & Grounded) should illuminate.
2. Power-Saving Measurement Initialization:
The HT705GR performs a power-saving detection
measurement after the green rocker switch is turned ON.
The Energy-Saving outlets will be turned on for 10 seconds,
and the energy-saving LED indicator will illuminate at the
same time. After initialization is complete, the Energy-Saving
outlets and energy-saving LED indicator will turn OFF, and
the unit is available for use. To reset the measurement of your
power consumption, press and hold the IR sensor button for
more than 10 seconds, release, and this will trigger a new
energy-saving measurement of the connected equipment.
3. The Energy-Saving Timer:
The energy-saving timer monitors the time period of power
delivery to the Energy-Saving outlets. The timer has a default
setting of 1 hour. If the timer does not receive any IR signal
during this window, it will turn o Energy-Saving outlets.
4.
4.
4.
4.4. Operation:
Turn TV ON. Power ON all connected equipment. When the IR
sensor receives IR signals, the Energy-Saving outlets will
power on. The IR sensor’s blue LED light will blink for 4.5
minutes after 1 hour after last click of remote to give user
a notice of shutdown. Click any button on a TV remote or the
volume button on a cable provider’s remote to restart
energy-saving timer at zero. Blue LED light will stop blinking.
5.
5.
5.
5.5. Setting the Energy-Saving Timer:
If you want to change the energy-saving time window, hold
the IR sensor button down for 7 seconds; LED light will flash 3
times, release. Press IR sensor 1 time. LED light will flash 1
time, and timer will be 1 hour. Hold the IR sensor button down
for 7 seconds. LED light will flash 3 times, release. Press IR
sensor 2 times, pausing in between. LED light will flash 2
times, and timer will be 2 hours.
6.
6.
6.
6.6. Timer Shut-Down:
When the timer expires, the IR sensor will continue to
flash for 5 minutes, then the Energy-Saving outlets will4.
power off.
K01-0000630-03


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: HT705GR
Kleur van het product: Zwart
Snoerlengte: 2.4 m
Aan/uitschakelaar: Ja
Responstijd: 1 ms
Stekker: NEMA 5–15P
Aantal producten inbegrepen: 1 stuk(s)
Surge energy rating: 1500 J
Aantal AC uitgangen: 7 AC-uitgang(en)
Nominale input voltage: 125 V
Stopcontacttypes: NEMA 5-15R
Nominale stroom output: 15 A
EMI/RFI geluidsfiltering: Ja
Piekstroom, common mode: 15000 A
Klem voltage: 500 V
EMI/RFI ruisverzwakking: 43 dB
Contacten met kinderbeveiliging: Ja
Piekstroom, normale modus: 60000 A

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower HT705GR stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd