CAUTION
TO REDUCE THE RISK OF ELECTRIC SHOCK:
Use only in dry locations and only indoors.
DO NOT plug into another relocatable power tap.
DO NOT “daisy chain” surge protectors.
DO NOT use with any aquarium equipment.
DO NOT use if properly grounded outlets are not available.
DO NOT install this device if there is less than 10 meters (30 feet) of wire between
the electrical outlet and electrical service panel.
DO NOT use for medical or life support equipment. This device features an internal
protection that will disconnect the surge protective component at the end of its
useful life, but it will maintain unprotected power to the load.
FOR MORE INFORMATION
Visit CyberPowerSystems.com for more information regarding:
• Product information and certifications
• Product warranty
• Connected equipment guarantee
TECHNICAL SUPPORT
Visit: CyberPowerSystems.com/support
Toll-Free: 1-877-297-6937
Š 2022 Cyber Power Systems (USA), Inc. All rights reserved.
All other trademarks are the property of their respective owners.
FEATURES
1. Surge Protected Indicator
Illuminated when the surge protection feature is
working properly.
2. Ground Indicator LED
Illuminated when the Ground protection feature is
working properly.
3. Pivoting Standard Grounded Outlets (6)
Pivoting outlets for ease of use and convenience, ts
standard-sized plugs.
TROUBLESHOOTING
If the grounded indicator does not light when you plug in the surge protector,
move the surge protector to a dierent grounded three-prong AC outlet. If it still
does not light, return the product to the retailer for assistance. If the surge
protector appears to be working properly, your outlets may not be properly
grounded and need to be repaired by a professional electrician.
If the protected indicator does not light, the surge protector’s AC lines are no
longer protected from surge. The surge protector may have received a power
surge or spike beyond its specied limits that overloaded the protection circuitry
and rendered it inactive. The surge protector has protected your connected
equipment as designed, but it will not protect against future surges, and spikes.
It should be replaced.
6-OUTLET
SURGE PROTECTOR
WALL-TAP
CSB600WS
USER MANUAL
YOUR ULTIMATE ALLY IN POWER
Cyber Power Systems (USA), Inc.
4241 12th Avenue East, Suite 400 | Shakopee, MN 55379
CyberPowerSystems.com
SPECIFICATIONS
Model Number: CSB600WS
Outlets: 6 Standard Grounded Outlets
Surge Protection: 900 Joules
Electrical Rating: 125 V / 15 A / 1875 W
UL Clamping Voltage: UL 1449 4th / 400 V
(H-N, H-G, N-G)
Maximum Peak Current: 45,000 A
3 AC Lines Protected: H-N: 15,000 A,
H-G: 15,000 A,
N-G: 15,000 A;
(The maximum surge possible on
household Wiring is 6,000 volts)
Response Time: Less than 1 nanosecond
Attenuation: Up to 32 dB
EMI/RFI Filtration: 150 kHz to 100 MHz
i WARNING: This product can expose you to chemicals including bisphenol A (BPA)
and styrene (ABS), which is known to the State of California to cause reproductive
harm and cancer. For more information, go to www.P65Warnings.ca.gov.
CONFORMANCE APPROVALS
This device complies with Part 15 of the FCC Rules.
Operation is subject to the following two conditions: (1) this
device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may
cause undesired operation.
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interfer-
ence to radio or television reception, which can be determined by
turning the equipment o and on, the user is encouraged to try to
correct the interference by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
WARNING: Changes or modications not expressly approved by the
party responsible for compliance could void the user’s authority to
operate the equipment.
2
1
3
3


Product specificaties

Merk: CyberPower
Categorie: Niet gecategoriseerd
Model: CSB600WS
Kleur van het product: Wit
LED-indicatoren: Ja
Certificering: UL1449
Duurzaamheidscertificaten: RoHS
Ophangsysteem voor aan de muur: Ja
Stekker: NEMA 5–15P
Verbeterd kabelbeheer: Nee
Aantal producten inbegrepen: 1 stuk(s)
Surge energy rating: 900 J
Aantal AC uitgangen: 6 AC-uitgang(en)
Nominale input voltage: 125 V
Stopcontacttypes: NEMA 5–15R
Nominale stroom output: 15 A
EMI/RFI geluidsfiltering: Ja
Klem voltage: 400 V
EMI/RFI ruisverzwakking: 32 dB
Piekstroom, normale modus: 45000 A

Heb je hulp nodig?

Als je hulp nodig hebt met CyberPower CSB600WS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd CyberPower

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd