Craftmade Topper TOP52BNK5 Handleiding


Pagina's 14 Ventilator

Bekijk de handleiding van Craftmade Topper TOP52BNK5 gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

WARNING:
DC Motor will not
operate until blades
are installed
Table of Contents:
Safety Tips. pg. 3
Unpacking Your Fan. pg. 4
Parts Inventory. pg. 4
Installation Preparation. pg. 5
Fan Assembly. pgs. 6 - 7
Wiring. pg. 8
Canopy Assembly. pg. 9
Blade Assembly. pg. 9
Light Kit Assembly (optional). pg. 10
Automated Learning Process./
Activating Code. pg. 11
Remote Control Operation. pg. 12
Activating Your Ceiling Fan Smart
Features. pgs. 12-13
Testing Your Fan. pg. 13
Troubleshooting. pg. 14
Warranty. pg. 14
Parts, Replacement or Technical
Assistance. pg. 14
page 1
net weight of fan: 21.61 lb (9.8 kg)
PRINTED IN CHINA
READ THESE INSTRUCTIONS AND
SAVE THEM FOR FUTURE USE
For Model:
TOP52*
*BNK nish is Indoor Use ONLY
Remote control and
receiver are pre-programmed.
Installation Guide
Topper
APPROVED FOR USE IN
WET LOCATIONS*
E192641
Activating Your New Smart Fan;
Downloading the Bond Home App
• Using your smart device, navigate to the application store (Apple App store or Google
Play), download the free Bond Home app and create account.
• Ensure the fan and receiver are receiving power from the house supply using the remote
control to turn the fan and light ON and OFF.
• Open the Bond Home App on your smart device and follow step-by-step instructions
included in the app to add your fan.
• Enjoy fan features and functionality that you can only get from activating the fan through
the app.
page 2
page 3
SAFETY TIPS.
READ ALL INSTRUCTIONS AND SAFETY INFORMATION CAREFULLY BEFORE INSTALLING YOUR FAN AND SAVE THESE INSTRUCTIONS.
WARNING
• To reduce the risk of electrical shock, turn o the electricity to the fan at the main fuse box or circuit panel before you begin fan installation
or before servicing the fan or installing accessories.
• To reduce the risk of re, electrical shock, or personal injury, mount to the outlet box marked "Acceptable for Fan Support of 15.9 kg (35 lb)
or less," and use the mounting screws provided with the outlet box. Most outlet boxes commonly used for the support of lighting xtures
are not acceptable for fan support and may need to be replaced. Consult a qualied electrician if in doubt.
• To reduce the risk of re, electrical shock, or personal injury, wire connectors provided with this fan are designed to accept only one
12-gauge house wire and two lead wires from the fan. If your house wire is larger than 12-gauge or there is more than one house wire to
connect to the corresponding fan lead wires, consult an electrician for the proper size wire connectors to use.
• If using this fan in a WET location, this fan must be connected to a supply circuit that is protected by a Ground Fault Circuit Interrupter
(GFCI) to reduce the risk of personal injury, electrical shock or death.
• To reduce the risk of re or electrical shock, do not use this fan with any solid state speed control device or control fan speed with a full
range dimmer switch. [Using a full range dimmer switch to control fan speed will cause a loud humming noise from fan.]
• To reduce the risk of personal injury, do not bend the blade arms during assembly or after installation.
• To reduce the risk of personal injury or damage to the fan, do not insert anything between the fan blades while they are rotating.
• To reduce the risk of serious bodily injury, DO NOT use power tools to assemble any part of the fan, including the blades.
• To avoid personal injury or damage to the fan and other items, be cautious when working around or cleaning the fan.
• This fan MUST be installed with the safety cable provided with the fan. Failure to use the safety cable provided may result in personal
injury, damage to the fan or damage to other property.
• Metal cover for use without light kit will be HOT if light is left on. To reduce the risk of personal injury, light kit must be OFF or
DISCONNECTED before installing metal cover.
• To reduce the risk of personal injury, use only parts provided with this fan. The use of parts OTHER than those provided with this fan
will void the warranty.
CAUTION
• To avoid personal injury, the use of gloves may be necessary while handling fan parts with sharp edges.
• Do NOT tamper with or attempt to repair LED component of xture. The light source is designed for this specic application and should
not be serviced by untrained personnel. If any servicing is required, call our customer service department.
• Changes or modications not approved by the party responsible for compliance could void the user's authority to operate the equipment.
[The equipment refers to the remote and/or wall control and/or LED light kit.]
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC
Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This
equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular
installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the
equipment o and on, the user is encouraged to try to correct the interference by one or more of the following measures:
* Reorient or relocate the receiving antenna.
* Increase the separation between the equipment and receiver.
* Connect the equipment into an outlet on a circuit dierent from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
• The LED light kit complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this LED light kit may not
cause harmful interference, (2) this LED light kit must accept any interference received, including interference that may cause undesired
operation.
1. Make sure all electrical connections comply with Local Codes or Ordinances, the National Electrical Code, and ANSI/NFPA 70-1999. If
you are unfamiliar with electrical wiring or if the house/building wires are dierent colors than those referred to in the instructions,
please use a qualied electrician.
2. Make sure you have a location selected for your fan that allows clear space for the blades to rotate and at least seven (7) feet
(2.13 meters) of clearance between the oor and the fan blade tips. The fan should be mounted so that the tips of the blades are at
least thirty (30) inches (76 centimeters) from walls or other upright structures.
3. The outlet box and ceiling support joist used must be securely mounted, and capable of supporting at least 35 pounds (16 kilograms).
The outlet box must be supported directly by the building structure. Use only CUL in Canada or UL in USA listed outlet boxes marked
"FOR FAN SUPPORT."
4. Electrical diagrams are for reference only.
5. After installation is complete, check that all connections are absolutely secure.
6. After making electrical connections, spliced conductors should be turned upward and pushed carefully up into the outlet box. The
wires should be spread apart with the grounded conductor and the equipment-grounding conductor on opposite sides of the outlet
box.
7. Do not operate the reverse switch until the fan has come to a complete stop. [Note: If using remote control with reverse capability,
reverse fan blade direction only when on LOW speed.]
8. Do not use water or detergents when cleaning the fan or fan blades. A dry dust cloth or lightly dampened cloth will be suitable for
most cleaning.
9. Light kit is dimmable to 10% with the remote control included.
Distributed by: Craftmade, 3901 S 20
th
Avenue, DFW Airport, TX, 75261; 800-486-4892
NOTE: The important safety precautions and instructions appearing in the manual are not meant to cover all possible conditions and
situations that may occur. It must be understood that common sense and caution are necessary factors in the installation and operation of
this fan.

Beoordeel deze handleiding


Product specificaties

Merk: Craftmade
Categorie: Ventilator
Model: Topper TOP52BNK5

Heb je hulp nodig?

Als je hulp nodig hebt met Craftmade Topper TOP52BNK5 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden