Citronic PL3200 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Citronic PL3200 (4 pagina's) in de categorie Receiver. Deze handleiding was nuttig voor 24 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
PL-series Powerlite Amplifiers
PL3200 (172.232)
PL3800 (172.238)
User Manual
Features:
Class H, 2-step architecture
Compact light weight and
High efficiency, high output
Independent dual-level clip limiters
Independent dual-level high-pass filters
Stereo, Parallel or Bridge Mono modes
Fully balanced signal path
Dual fan cooling
Soft-start on power up
Multi-level system protection
www.citronic.com
Introduction:
Thank you for choosing th Citronic Powerlite amplifier. This product has been designed to exacting standards to is
provide accurate, immediate high power on demand whilst remaining very lightweight and compact for easy
portability. The class H architecture and innate protection circuitry are designed to provide reliable service for many
years. Please, however, read and follow these instructions to attain the best performance from this amplifier and
avoid mis-use through incorrect operation.
Warning:
To prevent the risk of fire or electric shock, do not expose any of the components to rain or moisture.
If liquids are spilled on the casing, stop using immediately, allow unit to dry out and have checked by qualified
personnel before further use.
Avoid impact, extreme pressure or heavy vibration to the case
No user serviceable parts inside Do not open the case refer all servicing to qualified service personnel. – –
Safety
Check for correct mains voltage and condition of IEC lead before connecting to power outlet.
Ensure speaker leads are good condition with no short connections or damaged plugs
Check impedance of speaker loads do not exceed the minimum stated load for the amplifier
Do not allow any foreign objects to enter the case or through the ventilation grilles.
Placement
Keep out of direct sunlight and away from sources. heat
Keep away from damp or dusty environments.
When rack-mounting, ensure adequate support for the base of the amplifier and firm fixings for the front.
Ensure adequate air-flow and do not cover cooling vents at the front and rear of the amplifier
Ensure adequate access to controls and connections
Cleaning
Use a soft cloth with a neutral detergent to clean the casing as required
Use a vacuum cleaner to clear ventilation grilles of any dust or debris build-ups
Do not use strong solvents for cleaning the unit.
Front Panel
15. PM Protect Mode indicator 5. SIGNAL indicators
16. 6. BM Bridge Mono mode indicator CH1 and CH2 level controls
17. 7. CLIP indicators Cooling vent
18. 8. OUTPUT indicators POWER switch
Rear Panel
Operation
Connect speaker cabinets to channel outputs using good quality leads and ensuring that the combined load on
each channel is no lower than 4 Ω (for speaker loads connected from one to another, 8Ω + 8Ω = 4Ω).
Connect the left and right signal input from mixer or other line level source via the combo connectors on the rear
panel using good quality 6.3mm jack or XLR leads.
If the signal is to be cascaded onto other amplifiers, connect these via the XLR line level outputs.
Connect the amplifier to the mains outlet, making sure that the IEC lead is in good condition and connected
securely.
For extra protection of speakers and amplifier, the CLIP LIMITER may be switched in to help prevent overload.
In some extreme cases, the operation of the clip limiter can be obtrusive. In these cases, disable the clip limiter and
use a dedicated compressor/limiter to control the high dynamics.
If the amplifier is not driving sub cabinets or is driving cabinets which cannot produce very low frequencies, the High
Pass Filters (HPF) may be switched in to avoid excessively low frequencies, which will not be able to be reproduced
and thus dissipate as heat, reducing efficiency. Settings for 30Hz and 50Hz are available.
Select the GAIN level of the input signals (standard is 26dB may also be used to curtail the input level)
Select the mode in which the amplifier is to be used…
PARALLEL sums both left and right input signals together and feeds the mono signal to both amplifier
outputs. This is useful when driving sub cabinets (which, in arrays, benefit from working together in mono)
and when each channel is powering speakers in different areas (avoiding one area hearing only left output
and the other only right)
STEREO is the normal mode of operation where each input is delivered to each output independently
BRIDGE mode couples both amplifier sections together to deliver the full rated power to a single output.
The minimu m impedance is 8Ω in this mode. An LED (“BM”) shows when this mode is engaged
The GROUND LIFT switch disconnects signal ground (or “earth”) from mains ground. In certain cases, it may help
to alleviate mains hum otherwise, leave ground connected to mains ground.
9. Mains inlet - IEC 15. CLIP LIMITER switch
10. 6. CH2 output 1 GAIN input level selector
11. 7. Bridge mono output 1 MODE switch (Parallel/Stereo/Bridge)
12. 8. CH1 output 1 CH1 and CH2 High Pass Filters (HPF)
13. 19. Cooling vent GROUND LIFT switch
14. 20. Combo signal inputs (XLR or jack) Signal line outputs (XLR)


Product specificaties

Merk: Citronic
Categorie: Receiver
Model: PL3200

Heb je hulp nodig?

Als je hulp nodig hebt met Citronic PL3200 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Receiver Citronic

Handleiding Receiver

Nieuwste handleidingen voor Receiver