Page 1 of 6
M-CBF-L2 12_03_24
CBF SERIES
COMMERCIAL BATHROOM FAN
MODELS: CBF150, CBF300, CBF700
GENERAL SAFETY
DIMENSIONS & COMPONENTS
The purpose of this manual is to aid in the proper installation and operation of the Commercial Bathroom Fan (CBF). These instructions
are intended to supplement good general practices and are not intended to overwrite local codes and ordinances.
IT IS THE RESPONSIBILITY OF THE PURCHASER TO ENSURE THAT THE INSTALLATION AND MAINTENANCE OF THIS
EQUIPMENT IS HANDLED BY QUALIFIED PERSONNEL.
Inspect all shipments carefully for damage. THE RECEIVER MUST NOTE ANY DAMAGE ON THE CARRIER’S BILL OF LADING AND
FILE A CLAIM IMMEDIATELY WITH THE FREIGHT COMPANY.
All electrical work must be done in accordance with all applicable electrical codes by a 1.
qualified electrician.
Prior to wiring, ensure the power supply is locked in the OFF position and that the motor 2.
nameplate voltage matches the supply voltage.
The CBF bath fans should be permanently connected to the power supply. These are 3.
intended for commercial indoor use.
A 1 to 10VDC potentiometer comes standard and is pre-wired into your CBF unit to control 4.
the speed and performance of the fan. WARNING: DO NOT CONNECT/WIRE THIS FAN
TO A SUBSEQUENT OR REMOTE FAN SPEED CONTROL.
Caution:For general ventilation use only. Do not use to exhaust hazardous or explosive 5.
materials or vapors.
DO NOT install the fan directly over a bathtub or shower. NOT for use in a kitchen. 6.
Caution:The fan contains rotating parts and electrical service. Appropriate safety 7.
precautions should be taken during installation, operation and maintenance. When servicing,
the fan motor may be hot. Open grill and inlet, and allow time for it to cool down.
Before starting the unit, carefully remove the grill and ensure that the wheel rotates freely. 8.
Check and tighten all screws, nuts, bolts etc. prior to fan start up as some may have loosened 9.
during shipping.
When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden 10.
utilities.
Ducted fans must always be vented outdoors. To reduce risk of fire, use only metal ductwork. 11.
Sufficient air is needed for proper combustion and exhausting of gases through the flue 12.
(chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment
manufacturer’s guideline and safety standards such as those published by the National Fire
Protection Association (NFPA), and the American Society for Heating, Refrigeration, and Air
Conditioning Engineers (ASHRAE), and local code authorities.
This unit must be electrically grounded. 13.
Please follow all applicable national, state/provincial and local codes. All of them will 14.
supersede this manual.
Failure to follow the safety instructions in this manual may cause serious injury or death 15.
due to electrical shock or high speed rotating parts.
A
EE
B
F
D
C
H
J
L
K
A
E
E
F
B
H
J
L
K
D
G
D
G
C
#"!
!" 
!" 
!" 



OPERATION INSTRUCTIONS AND PARTS MANUAL
PLEASE READ AND SAVE THESE INSTRUCTIONS
CBF150
CBF300
CBF700
Page 2 of 6
CBF SERIES
COMMERCIAL BATHROOM FAN
M-CBF-L2 12_03_24
INSTALLATION
Remove fan and associated parts from its packaging. 1.
IMPORTANT: Remove tape securing the damper to the outlet flange prior to install and make sure that the damper opens/closes freely. 2.
To avoid damage to the fan, ensure the unit is cleaned out and free of construction debris - i.e. drywall tape or dust. 3.
Locate the joist mounting brackets. Note: They can be installed upward or flipped downward depending on the construction of the ceiling 4.
joists. They are height adjustable. Set them to the required depth and secure them with the bolts & nuts provided.
If you remove the mounting flanges and change their orientation or position, measure their position relative to your chosen installation 5.
method to ensure they are properly setup prior to install (). If you remove the flanges, be sure to to re-attach the speed dial. Fig. 1
When you plan your install, you must route the ductwork outdoors, either horizontally through a wall cap, soffit, or vertically through a roof 6.
cap. () Fig. 2
Carefully lift the unit into position and secure to ceiling joists or other permanent building structure. () Fig. 3 & 47.
Secure the flanges to the building’s structure with appropriate hardware and methods aligned with building codes in your jurisdiction. 8.
With the unit secure, you may now complete all duct work connections. Ensure the unit is vented outdoors. Use metal ductwork to reduce 9.
risk of fire. Be cautious to ensure the damper still opens freely when attaching duct to the outlet flange. Hardware pilot holes are provided.
Make sure the power is off at the breaker or source with proper lockouts installed and the unit is disconnected before wiring the motor. 10.
Remove the cover of the provided wiring compartment. Inside you will find power wires and ground screw. () Fig. 12 & 1311.
WARNING: To reduce risk of fire, electric shock or injury, please observe the following: Installation work and electrical wiring 12.
must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction.
With the wiring complete, reinstall the wiring box cover. Ensure you install a rated strain relief in the standard 7/8 electrical knockout. 13.
Look over the unit, make sure all fasteners and set screws are tightened, some may have loosened during shipping. 14.
Complete any construction required, and give the unit a final inspection prior to energizing it. 15.
Install the grill screen using the bolts provided. () Fig. 1416.
NOTE: The CBF can rotate its discharge and duct from the standard 90deg relationship to a straight up or 180 deg discharge. See 17.
Fig. 8 - 11 for details. You may need to rotate the potentiometer seen in Fig. 7 as well.
Page 3 of 6
CBF SERIES
COMMERCIAL BATHROOM FAN
M-CBF-L2 12_03_24
INSTALLATION CONTINUED