Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
REMINDER: Keep your dated proof of purchase for warranty purposes!
Attach it to this manual or file it for safekeeping.
IN625500AV 4/08
See Warranty on page 10 for important information about commercial use of this product.
Operating Instructions
© 2008
Portable Air Compressor
Table of Contents
Descripion...................... 1
Unpacking...................... 1
Safety Guidelines................ 1
General Safety Information........ 1
Introduction.................... 3
Assembly....................... 4
Operation...................... 6
Maintenance.................... 6
Troubleshooting Chart . . . . . . . . . . . . 8
Warranty...................... 10
Description
Air compressor units are intended
to provide compressed air to power
pneumatic tools and operate spray
guns. The pumps supplied are oil
lubricated. A small amount of oil
carryover is present in the compressed
air stream. Applications requiring air
free of oil or water should have the
appropriate filter installed. The air
compressor unit must be mounted
as described in the instructions on
a solid floor. Any other use of these
units will void the warranty and the
manufacturer will not be responsible
for problems or damages resulting from
such misuse.
Unpacking
After unpacking the unit, inspect
carefully for any damage that may
have occurred during transit. Make sure
to tighten fittings, bolts, etc., before
putting unit into service.
Do not operate unit
if damaged during
shipping, handling or use. Damage may
result in bursting and cause injury or
property damage.
You can
create
dust when you cut, sand, drill
or grind materials such as
wood, paint, metal, concrete,
cement, or other masonry. This dust
often contains chemicals known to
cause cancer, birth defects, or other
reproductive harm. Wear protective
gear.
READ & FOLLOW ALL INSTRUCTIONS
SAVE THESE INSTRUCTIONS
DO NOT DISCARD
Safety Guidelines
This manual contains information
that is very important to know and
understand. This information is
provided for SAFETY and to PREVENT
EQUIPMENT PROBLEMS. To help
recognize this information, observe the
following symbols.
Danger indicates an
imminently
hazardous situation which, if not
avoided, WILL result in death or serious
injury.
Warning indicates a
potentially
hazardous situation which, if not
avoided, COULD result in death or
serious injury.
Caution indicates a
potentially
hazardous situation which, if not
avoided, MAY result in minor or
moderate injury.
Notice indicates
important
information, that if not followed, may
cause damage to equipment.
NOTE: Information that requires special
attention.
General Safety Information
CALIFORNIA PROPOSITION 65
This product or
its power cord may
contain chemicals known to the State
of California to cause cancer and birth
defects or other reproductive harm.
Wash hands after handling.
Breathable Air Warning
This compressor/pump is NOT
equipped and should NOT be
used “as is” to supply breathing
quality air. For any application of
air for human consumption, you
must fit the air compressor/pump
with suitable in-line safety and
alarm equipment. This additional
equipment is necessary to
properly filter and purify the air
to meet minimal specifications
for Grade D breathing as
described in Compressed
Gas Association Commodity
Specification G 7.1, OSHA 29
CFR 1910. 134, and/or Canadian
Standards Associations (CSA).
DISCLAIMER OF WARRANTIES
In the event the compressor is
used for the purpose of breathing
air application and proper in-
line safety and alarm equipment
is not simultaneously used,
existing warranties are void, and
Campbell Hausfeld disclaims any
liability whatsoever for any loss,
personal injury or damage.
2
Operating Instructions
www.chpower.com
General Safety Information
(Continued)
GENERAL SAFETY
Since the air compressor and other
components (material pump, spray
guns, filters, lubricators, hoses, etc.)
used, make up a high pressure pumping
system, the following safety precautions
must be observed at all times:
1. Read all manuals included
with this product
carefully. Be thoroughly
familiar with the
controls and the proper use of the
equipment.
2. Follow all local electrical and safety
codes as well as in the United States,
the National Electrical Codes (NEC)
and Occupational Safety and Health
Act (OSHA).
3. Only persons well acquainted with
these rules of safe operation should
be allowed to use the compressor.
4. Keep visitors away and NEVER allow
children in the work area.
5. Wear safety glasses and
use hearing protection
when operating the unit.
6. Do not stand on or use the unit as a
handhold.
7. Before each use, inspect compressed
air system and electrical components
for signs of damage, deterioration,
weakness or leakage. Repair or
replace defective items before using.
8. Check all fasteners at frequent
intervals for proper tightness.
Motors,
electrical
equipment and controls can
cause electrical arcs that
will ignite a flammable gas
or vapor. Never operate or repair in or
near a flammable gas or vapor. Never
store flammable liquids or gases in the
vicinity of the compressor.
MANUAL
Never
operate
compressor without a
beltguard. This unit can
start automatically without
warning. Personal injury or property
damage could occur from contact with
moving parts.
9. Do not wear loose clothing or
jewelry that will get caught in the
moving parts of the unit.
Compressor parts may be hot
even if the unit is stopped.
10. Keep fingers away from a
running compressor; fast moving
and hot parts will cause injury and/
or burns.
11. If the equipment should start to
vibrate abnormally, STOP the engine/
motor and check immediately for
the cause. Vibration is generally a
warning of trouble.
12. To reduce fire hazard, keep engine/
motor exterior free of oil, solvent, or
excessive grease.
An ASME code
safety relief valve
with a setting no higher than 150 psi
MUST be installed in the tank for this
compressor. The ASME safety valve
must have sufficient flow and pressure
ratings to protect the pressurized
components from bursting.
See compressor
specification decal
for maximum operating pressure.
Do not operate with pressure switch
or pilot valves set higher than the
maximum operating pressure.
13. Never attempt to adjust ASME safety
valve. Keep safety valve free from
paint and other accumulations.
Never use plastic
(PVC) pipe for
compressed air. Serious injury or death
could result.
Never
attempt
to repair or modify a tank!
Welding, drilling or any other
modification will weaken the
tank resulting in damage from rupture
or explosion. Always replace worn,
cracked or damaged tanks.
Drain liquid from
tank daily.
14. Tanks rust from moisture build-up,
which weakens the tank. Make sure
to drain tank regularly and inspect
periodically for unsafe conditions
such as rust formation and corrosion.
15. Fast moving air will stir up dust
and debris which may be harmful.
Release air slowly when draining
moisture or depressurizing the
compressor system.
SPRAYING PRECAUTIONS
Do not
spray
flammable materials in
vicinity of open flame or near
ignition sources including the
compressor unit.
16. Do not smoke when spraying paint,
insecticides, or other flammable
substances.
17. Use a face mask /
respirator when spraying
and spray in a well
ventilated area to prevent
health and fire hazards.
18. Do not direct paint or other sprayed
material at the compressor. Locate
compressor as far away from the
spraying area as possible to minimize
overspray accumulation on the
compressor.
19. When spraying or cleaning with
solvents or toxic chemicals, follow
the instructions provided by the
chemical manufacturer.
3
www.chpower.com
Introduction
Refer to Figures 1a or 1b to locate the
following items.
Pressure switch - Auto/Off Switch - In
the "auto" position, the compressor
shuts off automatically when tank
pressure reaches the maximum preset
pressure. After air is used from the tank
and drops to a preset low level, the
pressure switch automatically turns the
motor back on. In the "off" position,
the compressor will not operate. This
switch should be in the "off" position
when connecting or disconnecting the
power cord from the electrical outlet.
When the pressure switch turns the
motor off you will hear air leaking out
of the pressure switch unloader valve
for a short time. This releases the air
pressure from the discharge tube and
allows the compressor to restart easier.
For units without a manual switch,
whenever the procedures call for
turning the switch to the OFF position,
use the switch at the disconnect instead.
Regulator - The regulator controls the
amount of air pressure released at the
hose outlet (Sold separately).
Tank Drain Valve - This valve is located
on the bottom of the tank. Use this
valve to drain moisture from the tank
daily to reduce the risk of corrosion.
Reduce tank pressure below 10 psi,
then drain moisture from tank daily to
avoid tank corrosion. Drain moisture
from tank(s) by opening the drain valve
located underneath the tank.
Tank Pressure Gauge - Indicates
amount of air pressure stored in tank.
Hose Pressure Gauge - Indicates
amount of air pressure in hose used to
operate tools. This pressure is increased
or decreased by the regulator.
ASME Safety Valve - This valve
automatically releases air if the tank
pressure exceeds the preset maximum.
Discharge tube - This tube carries
compressed air from the pump to the
check valve. This tube becomes very hot
during use. To avoid the risk of severe
burns, never touch the discharge tube.
To avoid the risk of
severe burns, never
touch the discharge tube.
Check valve - One-way valve that
allows air to enter the tank, but
prevents air in the tank from flowing
back into the compressor pump.
Handle - Designed to move the
compressor.
Never use the
handle to lift the
unit completely off the ground. Handle
is intended only for pushing or pulling
product.
Belt Guard - Covers the belt, motor
pulley and flywheel.
Never
operate
compressor without a
beltguard. This unit can
start automatically without
warning. Personal injury or property
damage could occur from contact with
moving parts.
Drain
Petcock
Handle
Pressure
Switch
Safety
Valve
Regulator
Discharge Tube
Check Valve
Belt
Guard
Tank
Breather/Dipstick
& Oil Fill Hole
Intake Filter
Tank Pressure
Gauge
Hose Pressure
Gauge
Figure 1a
Drain
Petcock
Handle
Safety
Valve
Regulator
Discharge Tube
Check Valve
Belt Guard
Tank
Breather/
Dipstick
& Oil Fill
Hole
Intake Filter
Hose Pressure
Gauge
Tank
Pressure
Gauge
Pressure
Switch
Figure 1b

Beoordeel deze handleiding


Product specificaties

Merk: Campbell Hausfeld
Categorie: Compressor
Model: VT6171

Heb je hulp nodig?

Als je hulp nodig hebt met Campbell Hausfeld VT6171 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden