Baxi Combi Instant 105e Handleiding

Baxi CV Ketel Combi Instant 105e

Lees hieronder de 📖 handleiding in het Nederlandse voor Baxi Combi Instant 105e (12 pagina's) in de categorie CV Ketel. Deze handleiding was nuttig voor 35 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/12
Baxi Combi Instant 80e & 105e
Gas Fired Wall Mounted Combination Boiler
User’s Operating Instructions
Please keep these instructions safe.
Should you move house, please hand
them over to the next occupier.
2
Baxi is one of the leading manufacturers of domestic heating
products in the UK.
Our first priority is to give a high quality service to our
customers. Quality is designed into every Baxi product -
products which fulfil the demands and needs of customers,
offering choice, efficiency and reliability.
To keep ahead of changing trends, we have made a
commitment to develop new ideas using the
latest technology - with the aim of continuing to
make the products that customers want to buy.
Everyone who works at Baxi has a commitment to quality
because we know that satisfied customers mean continued
success.
We hope you get a satisfactory service from Baxi. If not,
please let us know.
Natural Gas
Baxi Combi Instant 80e
G.C.No47 075 13
Baxi Combi Instant 105e
G.C.No47 075 09
Baxi is a BS-EN ISO 9001
Accredited Company
The boiler meets the requirements of Statutory Instrument “ The
Boiler (Efficiency) Regulations 1993 No3083” and is deemed to
meet the requirements of Directive 92/42/EEC on the energy
efficiency requirements for new hot water boilers fired with liquid
or gaseous fuels:-
Type test for purpose of Regulation 5 certified by:
Notified Body 0051.
Product/Production certified by:
Notified Body 0051.
For GB/IE only.
Legislation
3
Codes of Practice, most recent version should be used
IMPORTANT - Installation, Commissioning, Service & Repair
This appliance must be installed in accordance with the manufacturer’s instructions and
the regulations in force. Read the instructions fully before installing or using the
appliance.
In GB, this must be carried out by a competent person as stated in the Gas Safety
(Installation & Use) Regulations.
Definition of competence: A person who works for a CORGI registered company and
holding current certificates in the relevant ACS modules, is deemed competent.
In IE, this must be carried out by a competent person as stated in I.S. 813 “Domestic
Gas Installations”.
Lifting - This product should be lifted and handled by two people. Stooping should be
avoided and protective equipment worn where necessary. Carrying & lifting equipment
should be used as required, e.g. when installing in a loft space.
The addition of anything that may interfere with the normal operation of the appliance
without express written permission from the manufacturer or his agent could invalidate
the appliance warranty. In GB this could also infringe the Gas Safety (Installation and
Use) Regulations.
Warning - Check the information on the data plate is compatible with local supply
conditions.
Benchmark Commissioning Checklist
Please ensure that your installer hands you the boiler Installation & Servicing Instructions
with the Benchmark Commissioning Checklist sections completed. The details in the
Checklist will be required in the event of any warranty work. Keep the instructions in a
safe place and ensure that the Service Interval Record at the back is completed at each
service visit.
All CORGI registered installers carry a CORGI identification card and have a
registration number. You can check your installer is registered by telephoning
0870 4012300 or writing to:-
1 Elmwood,
Chineham Business Park,
Crockford Lane,
Basingstoke. RG24 8WG
or check online at www.corgi-gas-safety.com
Baxi declare that no substances harmful to health are
contained in the appliance or used during appliance
manufacture.
The appliance is suitable only for installation in GB and IE and
should be installed in accordance with the rules in force, and
only used in a suitably ventilated location.
In GB, the installation must be carried out by a CORGI
Registered Installer. It must be carried out in accordance with
the relevant requirements of the:
• Gas Safety (Installation & Use) Regulations.
• The appropriate Building Regulations either The
Building Regulations, The Building Regulations
(Scotland), Building Regulations (Northern Ireland).
• The Water Fittings Regulations or Water Byelaws in
Scotland.
• The Current I.E.E. Wiring Regulations.
Where no specific instructions are given, reference should be
made to the relevant British Standard Code of Practice.
In IE, the installation must be carried out by a competent Person
and installed in accordance with the current edition of I.S. 813
‘Domestic Gas Installations’, the current Building Regulations and
reference should be made to the current ETCI rules for
electrical installation.
All systems must be thoroughly flushed and treated with
inhibitor.
In GB the following Codes of Practice apply:
Standard Scope
BS 6891 Gas Installation.
BS 5546 Installation of hot water supplies for
domestic purposes.
BS 5449 Forced circulation hot water systems.
BS 6798 Installation of gas fired hot water boilers.
BS 5440 Part 1 Flues.
BS 5440 Part 2 Ventilation.
BS 7074 Expansion vessels and ancillary equipment
for sealed water systems.
BS 7593 Treatment of water in domestic hot water
central heating systems.
In IE the following Codes of Practice apply:
Standard Scope
I.S. 813 Domestic Gas Installations.
The following BS standards give valuable additional information;
BS 5546 Installation of hot water supplies for
domestic purposes.
BS 5449 Forced circulation hot water systems.
BS 7074 Expansion vessels and ancillary equipment
for sealed water systems.
BS 7593 Treatment of water in domestic hot water
central heating systems.


Product specificaties

Merk: Baxi
Categorie: CV Ketel
Model: Combi Instant 105e

Heb je hulp nodig?

Als je hulp nodig hebt met Baxi Combi Instant 105e stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding CV Ketel Baxi

Handleiding CV Ketel

Nieuwste handleidingen voor CV Ketel