Astralpool ZX 100 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Astralpool ZX 100 (6 pagina's) in de categorie Waterfilter. Deze handleiding was nuttig voor 26 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/6
INSTALLATION AND
OPERATING INSTRUCTIO NS
Melbourne: 03 8796 8600 Gold Coast: 07 5552 2600 Perth: 08 9350 2600
Sydney: 02 9853 2100 Townsville: 07 4750 3100 sales@astralpool.com.au
Brisbane: 07 3308 5400 Adelaide: 08 8152 7600 www.astralpool.com.au
INSTALLATION AND OPERATING INSTRUCTIONS I INSTALLATION AND OPERATING INSTRUCTIONS
ZX Series Cartridge
Filter
INST 247 ZX Series Cartridge Filter 5 7 V0 .1
2
INTRODUCTION
Congratulations on the purchase of your AstralPool ZX series cartridge lter.
The ZX series lters are made to last by utilising the best quality materials available. The tank is made from high quality
ABS plastics, capable of withstanding the harshest of environments while DuPont Remay elements are used which are
regarded by the industry as the best available. Include with this Mircoban antimicrobial coating on the elements and
you are sure to achieve one of the cleanest pools possible.
WARNING: DO NOT OVERTIGHTEN LOCKING RING AS THIS MAY CAUSE THE FILTER TO LEAK. GENTLE HAND
TIGHT IS SUFFICIENT FOR CORRECT SEALING.
INSTALLATION OF ZX SERIES
1. Ensure cartridge lter is located on a clean, stable and level base.
2. The ZX series lter has three inlet ports (from pump) and one outlet port (to pool/spa). Glue one of the 50mm slip
tails supplied into one of the inlets and second slip tail supplied into the outlet of the lter that suits the plumbing
conguration.
3. Glue in the supplied blanking cap and drain plug cap into the two remaining inlets. Allow a minimum of one hour
for glue to dry before subjecting lter to system pressures.
4. Glue water connection pipes from pump and pool return to 50mm tails supplied. (Ensure locking nut is placed on
pipe before gluing on tails.
5. Apply Teon tape (not included) to the pressure gauge and screw into lid where indicated.
START UP INSTRUCTIONS
1. Before starting your ZX lter, make sure the cartridge is in the lter and the lid and lock ring are in place and up
tightened.
2. Open the suction and return line valves (when tted).
3. Start pump and open the air release valve on the filter lid 2 to 3 turns air will begin to be forced from the tank.
Once water begins to ow from the valve, tighten to close. Check there is a good ow of water back in the pool. to
4. Clean the cartridge when the ow to the pool reduces or the pressure gauge increases by 15 20 kPa.
PUMP PRIMING
1. With the pump OFF, remove the lid from the pump strainer and ll with water to the top of the lit pot.
2. Replace and tighten lid on pump.
3. If valve has been installed on the pump suction line, close before lling strainer. Open again after lid has been
securely fastened in place. Any valves on the return lines should be open. The pump should not need to be re-
primed unless the pump has been drained for servicing, or winterizing (refer to complete pump operations manual
provided with pump).
INST 247 ZX Series Cartridge Filter 5 7 V0 .1
3
TO CLEAN FILTER CARTRIDGE ON ZX SERIES
1. Stop pump-close valves on the suction and return lines.
2. Open the air bleed valve on the lid.
3. Proceed to loosen locking ring on lter. As you turn the locking ring, the lid of the lter will be lifted out of the
body. Once lid is free of the body, lift lid and locking ring together and place in a clean location. You can now
remove the cartridge.
4. Clean the cartridge by soaking it in a mild solution of chlorine and warm water for 15 minutes and then hose o
with water. Alternatively, special formulated element cleaning solutions can be purchased from most pool
professionals. (Note: do not use high powered water jets to clea this may cause damage to the element) n
5. Replace the cartridge; ensure correct location on the bottom spigot.
6. Insert the top locating spigot into the element.
7. Clean the lid, locking ring and These should be rinsed with clean water to ensure not grit or grime has lid ‘o’ ring.
deposited into the threads. Replace the lid and locking ring onto the top of the lter tank, ensuring correct
alignment with the locating spigot..
8. Commence tightening the lid lock ring the lid will begin to be pulled down into the lter tank. Continue to tighten
the lock ring until safety catch locks into place. DO NOT OVERTIGHTEN LOCKING RING AS THIS MAY CAUSE
THE FILTER TO LEAK. GENTLE HAND TIGHT IS SUFFICIENT FOR CORRECT SEALING.
9. Open the valves start the pump.
NEVER LOOSEN THE LOCK RING WHEN THE PUMP IS WORKING
FILTER SPECIFICATIONS
MODEL
PART
NO.
ELEMENT
PART
NO.
FLOW
RATE
L/Hr
FLOW
RATE
L/M
4 HR
TURN
OVER
6 HR
TURN
OVER
PUMP
SIZE
SHIP
KG’S
CUBIC
MEASURE
ZX50
10040
78095
13,500
225
54,000
81,000
550w
750w
7.0 kg
0.0 75m3
ZX75
10041
78096
17,400
290
70,000
104,000
550w
1100w
7.8 kg
0.0 75m3
ZX100
10042
78097
22,500
375
90,000
135,000
750w
1100w
9.6 kg
0.101 m3
ZX150
10043
78098
28,500
445
106,800
160,200
750w
1500w
9.9 kg
0.101 m3
ZX200
10044
78099
29,400
490
117,600
176.,400
750w
1500w
11.8 kg
0.127 m3
ZX250
10045
78094
30,900
515
123,600
185,400
750w
1500w
12.2 kg
0.127 m3
ZX310
10046
780
32700
545
130800
196200
750w
1500w
14.3 kg
0.153m3


Product specificaties

Merk: Astralpool
Categorie: Waterfilter
Model: ZX 100

Heb je hulp nodig?

Als je hulp nodig hebt met Astralpool ZX 100 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Waterfilter Astralpool

Handleiding Waterfilter

Nieuwste handleidingen voor Waterfilter