Bekijk gratis de handleiding van Apc Switched Rack PDU (18 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 44 mensen en kreeg gemiddeld 4.0 sterren uit 22.5 reviews. Heb je een vraag over Apc Switched Rack PDU of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/18

Overview and Specifications
990-3456B Release Date: 11/15/21
APC
70 Mechanic Street
02035 Foxboro, MA
USA
www.apc.com
As standards, specifications, and design change from time
to time, please ask for confirmation of the information
given in this publication.
© 2021
Schneider Electric. APC, the APC logo, and
EcoStruxure are trademarks of Schneider Electric SE or its
subsidiaries. All other brands may be trademarks of their
respective owners.
Switched Rack Power Distribution Unit (AP8653)
Overview
The APC Switched Rack Power Distribution
Unit (PDU) distributes power to devices in a
rack. The PDU measures total load plus
phase, bank, and outlet load. In addition,
configured users can control the state of the
outlets. You can access the PDU through
Web, Telnet, SNMP, SSH, or EcoStruxure™
IT Expert interfaces for comprehensive
control and monitoring functionality.
Outlets. The Rack PDU has twenty-one (21)
IEC-320-C13 and three (3) IEC-320-C19
locking outlets . (The locking feature is
compatible with APC locking input cords and
APC locking jumper cords.)
Overcurrent protection. The Rack PDU
has two (2) 16 A, 1-pole hydraulic-magnetic
circuit breakers
1.
Display interface. The liquid crystal display
(LCD) and input buttons allow you to
monitor current, power, and voltage
measurements of the Rack PDU. Local
communication can be established through
the serial port , and remote communication
through the network port . The USB port
allows for firmware upgrades, and the CAN
ports enable data transfer for future
expansion options. The environmental sensor
port allows for monitoring of the
temperature and humidity of the room or
enclosure.
Power cord. The 3.0-m (10-ft) power cord
terminates with a 32 A, 3-pin IEC-309
connector
:.
Toolless mounting: The Rack PDU has two toolless mounting pegs for 0 U mounting
capability in a rack or enclosure.
TRIPPED
TRIPPED
pdu0558a
Network
Main
Menu
Scroll
Select
In Serial
USB
Out
Temp/Humidity
10
/
100
x
Reset
Warning
OK
Overload
By ElectricScheider
Rack PDU
Network
Main
Menu
Scroll
Select
In Serial
USBOut
Temp/Humidity
10/
100
x
Reset
Warning
OK
Overload
By ElectricScheider
Rack PDU

990-3456B Release Date: 11/15/21
Specifications
Electrical
Acceptable input voltage 220–240 VAC +6%, -10%
Maximum input current (phase) 32 A
Input frequency 50/60 Hz
Input connection IEC 309-32A 3-pin
Input power 7.4 kVA
Output voltage 220–240 VAC
Maximum output current (outlet) IEC-320-C13: 10 A; IEC-320-C19: 16 A
Maximum output current (phase) 32 A
Output connections Twenty-one (21) IEC-320-C13; three (3) IEC-320-C19
Physical
Dimensions (H x W x D)
(depth does not include t
oolless pegs) 182.9 x 5.6 x 5.1 cm (72.0 x 2.2 x 2.0in)
Powe
r cord length 3.0 m (10 ft)
Shipping dimensions
(H x W x D)
203.8 x 16.2 x 11.8 cm (80.25 x 6.38 x 4.63 in)
Weight/shipping weight 8.2 kg (18.1 lb) / 10.5 kg (23.1 lb)
Environmental
Maximum elevation (above MSL)
Operating/Storage
0–3 000 m (0–10,000 ft) / 0–15 000 m (0–50,000 ft)
Temperature
Operating/Storage
–5 to 45°C (23 to 115°F) / –25 to 65°C (–13 to 149°F)
Humidity
Operating/Storage
5–95% RH, non-condensing
Compliance
EMC verification
EN55032, EN55035, EN 61000-3-2, EN61000-3-3,
KN 32, KN35
Safety verif
ication UL-EU,
CE, EAC, RCM, CMIM, UKCA
Product specificaties
Merk: | Apc |
Categorie: | Niet gecategoriseerd |
Model: | Switched Rack PDU |
Kleur van het product: | Zwart |
Gewicht: | 8230 g |
Snoerlengte: | 3 m |
Gewicht verpakking: | 10500 g |
Soort: | Eenfasig |
Afmetingen verpakking (BxDxH): | 162.00 x 118.00 x 2038.00 mm |
Certificering: | EN 55022 Class A, EN 55024, EN 61000-3-2, EN 61000-3-3, VDE |
Duurzaamheidscertificaten: | RoHS |
Temperatuur bij opslag: | -25 - 65 °C |
Stroomspanning bescherming: | Overbelasting |
Luchtvochtigheid bij opslag: | 5 - 95 procent |
Hoogte, in bedrijf: | 0 - 3000 m |
Hoogte bij opslag: | 0 - 15000 m |
Maximaal vermogen: | 7680 W |
Afmetingen (B x D x H): | 56.00 x 51.00 x 1829.00 mm |
Montage: | Verticaal |
Stekker: | IEC309 |
Rackcapaciteit: | 0U |
AC-ingangsfrequentie: | 50 - 60 Hz |
Bedrijfstemperatuur (T-T): | -5 - 45 °C |
Relatieve vochtigheid in bedrijf (V-V): | 5 - 95 procent |
Aantal AC uitgangen: | 24 AC-uitgang(en) |
Nominale input voltage: | 230 V |
Stopcontacttypes: | C13 coupler, C19 coupler |
Stroom (max.): | 32 A |
PDU types: | Metered, Metered-by-outlet, Switched |
Netspanning, in bedrijf: | 230 V |
Monitoring: | Current, Power, Voltage |
Outlet controle: | Lock-out, Recycle, Turn off, Turn on |
Laad-capaciteit: | 7680 VA |
Maximale ingang stroom per fase: | 32 A |
Maximum totaalstroomverbruik per fase: | 32 A |
Heb je hulp nodig?
Als je hulp nodig hebt met Apc Switched Rack PDU stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Apc
8 September 2025
15 Juli 2025
14 Juli 2025
14 Juli 2025
14 Juli 2025
24 Mei 2025
2 Mei 2025
2 Mei 2025
2 Mei 2025
8 April 2025
Handleiding Niet gecategoriseerd
- MyGoFlight
- AudioControl
- Crucial
- Creda
- Hitachi
- Hamax
- Ernitec
- MARTOR
- ACE
- Yamazen
- Browin
- Adviti
- Nexcom
- Razor
- Dynon Avionics
Nieuwste handleidingen voor Niet gecategoriseerd
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025
15 September 2025