Westinghouse WRJ903UW Handleiding


Lees hieronder de đź“– handleiding in het Nederlandse voor Westinghouse WRJ903UW (4 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 31 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/4
Universal Cooker Hood Installation and Operation Manual
The instructions in this manual are for cooker hood models:
Safety Warning
Cleaning
Electrical Connection
Accessories
Ducting Accessories
WRJ903U, WRJ600U, WRJ603U, WRJ611U, WRJ900U,WRJ911U, RHN6, RHN9, RFD602W, RFD602S, RFD902W, RFD902S
These cooker hoods are domestic appliances which have been manufactured and tested to comply with Australian and New Zealand
Standard AS/NZS 3350.2.31.
This nce is not int d for e by rsons nc g c ) with uced physical, sensory or ntal c ities, or lack of ex nce applia ende us pe (i ludin hildren red me apabil perie
and knowledge, unless they have been given supervision or insruction concerning use of the appliance by a person responsible for their safety.
Children should be supervised to ensure they do not play with the appliance.
Ensure the cooker hood is switched off before carrying out maintenance, to avoid any possibility of electric shock.
Do not under the cooker hood.
This cooker hood is not recommended for .barbeques
Exhaust air must not be discharged into a wall cavity, unless the cavity is designed for the purpose.
There must be adequate ventilation of the room when the cooker hood is used at the same time as appliances burning gas or other fuels.
Always cover lit gas burners with pots or pans when the cooker hood is in use.
Always switch off gas burners before you remove pots or pans.
CAUTION: Accessible parts may become hot when used with cooking appliance.
. use oven cleaners or other abrasive Do not
materials.
Check that the mains voltage matches with the voltage on the data plate inside the cooker hood.
Check that the installation complies with standards of local gas and electricity authorities.
Use 125mm round exhaust ducting for best performance.
Try to keep exhaust duct short and straight.
Keep bends in the exhaust duct to a minimum.
Do not reduce the size or restrict exhaust duct.
These appliances are intended to be used in household and similar applications such as:
-Farm Houses
-By clients in hotels, motels and other residential type environments
-Bed and breakfast type environments
AR125RC
AR125F
AR125FD
AR125WV
Roof cowl
Flue
1200mm length
Alternative flue connection
1 metre flexible duct with joiners
Wall vent
(includes 400mm of flue)
Flue collar
1 supplied
with hood
Flue joiner
-plain AR125FJ
-damper
AR125FJD
Flashing
Not Supplied
90 bend
AR125B
Flue
600650
GAS
ELECTRIC
(MINIMUM)(MINIMUM)
Stainless Steel Models
Setting of circulation air door - single fan models
IMPORTANT: SET CIRCULATING MODES BEFORE INSTALLING THE HOLE PLUGS.
Ducted installation
Setting of circulation air doors - dual fan models
Select required exhaust outlet, remove hole
plug and snap t ue exhaust collar.
Before installing the cooker hood, remove all protective plastic covering from stainless steel surfaces.
Use at least 4 screws (not provided) and the mounting holes provided to securely mount the cooker hood. Make sure that the cooker hood is level
and free from twist.
Warning: Failure to install the screws or îšżxing device in accordance with these instructions may result in electrical hazards.
c
L
c
L
60
100
79
25
25
30
25
Air Recirculating Outlet
Rear Fixing Points (4)
143
Recommended
Top Fixing Points
Recommended
90cm wide models
60cm wide models
nominal width 598
nominal width 898
(use 2 from each end)
160
500
Top and Rear Exhaust Outlets
35
300
30
105
The maximum space between
the wall and screw cap is 5mm
RECIRCULATE
EXHAUST
RECIRCULATE
EXHAUST
Cooker Hood Operation
Slide switch controls Press button switch controls
Maintenance:
Recirculating accessory:
Replacing lamps:
IMPORTANT: The Edison Screw lamps may have come loose during transportation. Ensure that lamps are tightened îšżrmly into the socket
before power is applied.
Best results are obtained by using a low speed for normal conditions and a high speed when odours are more concentrated. Turn the hood on a few
minutes before you start cooking. It should by left on after cooking for about 15 minutes or until all odours have disappeared.
Light switch:
Extractor fan switch:
Slide position I:
Slide position II:
Slide position III:
Light switch: ON Depress light button to turn light . Press light button
to turn light .OFF
Extractor fan switch interlocked switching: Select a fan
speed, depress button to turn fan . Press button to turn fan ON (O)
OFF.
Clean grease îšżlters every three to four weeks maximum. Greasy îšżlters
are a îšżre risk.
Remove the grease îšżlters, soak and agitate in hot soapy water.
Rinse, drain and shake well before replacing îšżlters.
Do not use oven cleaners or other caustic materials.
Optional carbon îšżlter ARCFD for recirculating mode only.
Ensure the appliance is switched o before carrying out maintenance,
to avoid any possibility of electric shock. Remove grease îšżlter to
replace lamp. Replace with 40W (maximum) E14 candle lamp.
This switch is used to turn the light îšżtted in the
hood on and o.
Used to select fan speeds
Fan speed Lo.
Fan speed Med.
Fan speed High.


Product specificaties

Merk: Westinghouse
Categorie: Afzuigkap
Model: WRJ903UW

Heb je hulp nodig?

Als je hulp nodig hebt met Westinghouse WRJ903UW stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Westinghouse

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap