TROUBLE SHOOTING
FAULT POSSIBLE CAUSES REMEDY
Burner will not light even
though the sparker is
working.
Knob not held down long enough
in ‘High’ or ‘Max’ position for flame
safeguard
to engage
Repeat lighting procedure and hold knob down for
5 seconds in ‘High’ or ‘Max’ position
(refer page 7)
Gas supply valve turned off Turn on gas supply to appliance
Wrong knob turned Ensure the knob you are turning corresponds
to the burner you want to light
Port blockage in ignition area Ensure that ports in ignition area are clean
and dry
Ignition spark plugs wet or dirty • Dry or clean ignition spark plugs
No spark is obtained when
control knob
is activated
Electricity supply is disconnected or
switched off
• Switch on electricity or check fuses
• Ignition spark plugs wet or dirty Dry or clean ignition spark plugs
Flames uneven or tending
to lift
• Flame ports blocked or wet • Clean or dry flame ports
• Burner incorrectly fitted • Ensure this component is fitted correctly
Flames not staying on when
knob released
Knob not held down long enough
in ‘High’ or ‘Max’ position for flame
safeguard
to engage
Repeat lighting procedure and hold knob down for
5 seconds in ‘High’ position
(refer page 7)
• Knob not set between ‘High’ and ‘Low’ • Knob MUST be set between these positions
Dirt or spillage on flame safeguard sensor • Clean flame safeguard sensor tip
Low heat, slow cooking • Incorrect cooking pot or pan being used • Refer to Figure 4
Benchtop or knobs
overheating
• Incorrect cooking pot or pan used Check Figure 4 for correct pot or pan to be used
Pot or pan not located on burner properly Ensure pot or pan is centrally located
on burner
Cooktop stainless steel
discoloured
• Pot or pan being used is too large • Ensure pot sizes used are as per user manual
requirements. Clean with STEEL POWER (available
through spare parts)
Outer ring of wok burner
goes out when set to low
This is not a failure. This is a function of the
dual wok burner to give a very low power
flame option
Burner is functioning as intended
Elements giving off smoke or
odours when first used
Protective oils being removed in first
cooking
Do not worry, this is normal
Red rings, limescale or water
rings, shiny metallic or other
discoloration, scratches/
shadows, bubbles or other
miscellaneous marks or
stains on ceramic glass
cooktop surface
Cooktop surface has not been cleaned
correctly. Cleaning of the cooktop surface
is not coveredunder warranty. If a service
call is places to clean the cooktop you will
be charged for the visit.
Use a ceramic glass cleaner such as Cerapol
If the above points have been checked and there is still a problem with the cooktop, please call the Service Centre.
If you have a problem with the cooktop, check the table
below. You may be able to solve the problem and this
will save you from paying for a service call. You will have
to pay for a service call even in the warranty period if
the problem is one listed below.
17
OPERATION ON N.G./S.N.G
This appliance is supplied for use with Natural Gas.
However, it can be converted for use with LPG.
Refer to LP conversion on page 19.
Supply pipe sizing
The total hourly gas consumption for the appliance is
shown on the data label. The required supply pressure (i.e.
at inlet to appliance regulator) for each gas type is shown
on the data label, and given in Table 3 (page 18). Use this
information in conjunction with the length of run, number
of elbows, tees and bends, the available service pressure
and the supply requirements of other installed appliances
to determine a suitable pipe size. For assistance in this
matter refer to the appropriate section of AS/NZS 5601.1
or AS/NZS 5601.2.
An AGA certified class B or D flexible connection may
be used to connect the cooktop in accordance with
AS/NZS 5601.1, in particular section 5.9 and clause
6.10.1.8, or AS/NZS 5601.2, in particular section 2.11.
Where a hose assembly is used and the cooktop is in the
installed position, the hose assembly shall be suitable for
connection to a fixed consumer piping outlet located at
a point 800 850mm above the floor and in the region
outside the width of the appliance to a distance of 250mm.
The point of connection to consumer piping must be
accessible with appliance installed.
ELBOW POSITIONING
It is possible to reposition the elbow if required by
loosening the locking nut and elbow by using two
spanners. Re-tighten the entire assembly after the elbow
has been repositioned. When fitting elbow to appliance,
ensure that the sealing washer is fitted.
Note to Installer: Assembly of elbow to manifold at rear
of unit requires two spanners to secure locking nut and
ensure leak free connection. For this reason the elbow is
best secured onto cooktop manifold before installing unit
into benchtop.
Regulator
An appliance regulator is provided. The regulator must be
positioned so that the pressure test nipple is accessible
when the appliance is installed.
Connect the gas supply to the ½B.S.P. internal thread
inlet of the regulator. Refer to ‘bench cutout(Figure 8) for
connection point position.
Regulators are supplied pre-adjusted and configured by the
component maker for use with Natural Gas.
The appliance installer is not required to make an
adjustment to obtain the correct outlet pressure setting.
An arrow on the base of the regulator indicates the
direction of gas flow when the inlet and outlet of the
regulator is orientated correctly. When the regulator has
beentted check for leaks from the connections with
soapy water.
GAS CONNECTION