Vimar 01580 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Vimar 01580 (5 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 14 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/5
Installer manual
01580-01581-01582-01585-01586-01587
Home automation system push button control devices, KNX standard
SMART HOME&BUILDING
19
Home automation system push button control devices, KNX standard
List of existing communication objects and standard settings
ACTUATOR FUNCTIONAL UNIT
Communication objects and ETS parameters
C R W T = Communication; = Read; = Write; = Transmission; = Enable updateU
Number Name in ETS Function in ETS Description Length Flag
C R W T U
0 OUT ON/OFF (If the output is enabled as "Switching module") to switch the output ON/
OFF 1 bit X X
1 OUT Stair light (If the output is conïŹgured as “Stair light”) to control the output with timer 1 bit X X
2 OUT Block (If the Out 1 "Block" parameter is activated with "Block" function) to inhibit
the Output control from the bus 1 bit X X
3 OUT Force (If the Out 1 "Block" parameter is activated with "Forcing" function) to
force output to ON/OFF from the bus 2 bit X X
4 OUT Scenario (If the output "Scenario" parameter is on), to activate and, if required, store
(if the parameter is active) a scenario associated with the output 1 byte X X
5 OUT State (If the output is enabled as "Switching module” or “Stair light”) to know
the state of the output 1 bit X X X
6 OUT Logic 1
(If "1/2-object logic" is activated on the output) if a bit = 1 is sent to this
object the output will be activated when the "ON/OFF" object and the
"Logic 2" object, if present, are also activated (depending on the And/Or
conditions that are managed on these objects)
1 bit X X
7 OUT Logic 2
(If "1/2-object logic" is activated on the output) if a bit = 1 is sent to this
object the output will be activated when the "ON/OFF" object and the
"Logic 1” object are also activated (depending on the And/Or conditions
that are managed on these objects)
1 bit X X
Communication objects: default settings
Number Name in ETS Function in ETS Length Priority Flag
C R W T U
0 Output A ON/OFF 1 Bit Low X X
1 Output A Stair light (one-position stable Out) 1 Bit Low X X
2 Output A Block 1 Bit Low X X
3 Output A Forced 2 Bit Low X X
4 Output A Scenario 1 byte Low X X
5 Output A State 1 Bit Low X X X
6 Output A Logic 1 1 Bit Low X X
7 Output A Logic 2 1 Bit Low X X
C R T = Communication, = Read, W = Write, = Transmission, = Enable updateU
Standard communication object settings
Number of communication objects Max. number of group addresses Max. number of associations
8 254 255
22
Home automation system push button control devices, KNX standard
ETS text Values available Comment
[Default value]
Type
0=normally open
1=normally closed
[0]
Stair Light time [s] 0... 30000 Output activation time
[120]
Switch off warning
0=off Possibility of choosing a
warning that the light will soon
switch off
1=on
[0]
Warning time [s]
0... 30000
If "Off warning" is on: having
set a “warning time” and a
“prewarning time”, when the
relay is switched off after
the "stair light time" set, this
remains Off for a time equal to
the "warning time" and then
comes on again for a time
equal to the "prewarning time"
[1]
Prewarning time [s]
0... 30000
Warning time (if "Off warning" is
on). Three times will be added.
Having set a “warning time”
and a “prewarning time”, when
the relay is switched off after
the "stair light time" set, this
remains Off for a time equal to
the "warning time" and then
comes on again for a time
equal to the "prewarning time"
[10]
Manual off
0=off Possibility of choosing whether
an OFF request when activating
the output is managed or not
1=on
[0]
Behaviour during
block
0=Off If block on.
If the bus is switched off the
block/force state is lost and
then when the bus is switched
back on the actuator follows
the "Behaviour at Bus power
up” parameter.
1=On
2=no change
[2]
Behaviour if not
blocked
0=Off If block on.
Caution: if at the end of the
block the output needs to be
actuated to return it to rest
mode, an ON must be sent to
the “Stair light” object, waiting
for the “Stair light time” or an
OFF must be sent to the “Stair
light” object (OFF only works if
the “Manual off” parameter is
active).
1=On
2=no change
[2]
Behaviour at Bus
power-on
0=Off Note 1: in cases 0 and 1, if
the output is active, as per the
block state described in the
previous parameter to disable
the output send an OFF or an
ON and wait for the “Stair light
time".
Note 2: After downloading
the application via ETS, the
actuator follows this parameter
request and switches to OFF,
ON or maintains the state
saved when the Bus was last
switched off.
1=On
2=no change
[2]
Behaviour at Bus
power off
0=Off
1=On
2=no change
[2]
Stair light parameters (one-position stable output management)
Stair light parameters
Output, timed stair light
If the output is configured as a stair light, the following
parameters are visible:
Communication objects and ETS parameters


Product specificaties

Merk: Vimar
Categorie: Niet gecategoriseerd
Model: 01580

Heb je hulp nodig?

Als je hulp nodig hebt met Vimar 01580 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Vimar

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd