Professional Built-in Hoods
Installation
Table of Contents
2
Warnings & Important Information
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 3
VWH 10”H. Wall Hoods w/Standard Ventilator 30”, & 36”
D i m e n s i o n s & S p e c i f i c a t i o n s _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 5
Clearance Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 6
Interior Ventilator Dimensions _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 7
Planning Information _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 8
Installation Procedures
Installation (VWH 10”H. Wall Hoods w/Standard Ventilator) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 9
Duct Cover Option (VWH 10”H. Wall Hoods w/Standard Ventilator)_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11
Installation (VWH 10”H. Wall Hoods w/Recirculating Kit) _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 11
Service & Registration_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ 1 5
3
IMPORTANT–Please Read and Follow!
NOTE:
NOTE:
NOTE:
NOTE:NOTE:
If installing hood with warming shelf panel,
install warming shelf panel first.
IMPORTANT – PLEASE READ AND FOLLOW
• Before beginning, please read these instructions
completely and carefully.
• Do not remove permanently affixed labels,
warnings, or plates from the product. This may
void the warranty.
• Please observe all local and national codes and
ordinances. If no local codes are applicable, wire
in accordance with the National Electrical Code,
ANSI/NFPA 70-latest edition.
• Damp environment approved models should be
installed in a covered non-enclosed area and
should be protected from the elements as much
as possible.
• The installer should leave these instructions with
the consumer who should retain for local
inspector’s use and for future reference.
• Check with a qualified and trained installer or local
codes for makeup air requirement, if any.
This hood is for residential installation only and is
not designed for installation over a commercial
product. Make sure power is off at the main circuit
breaker or fuse box before making connections. To
avoid risk of fire, electric shock, or injury to persons,
turn off the electricity to the hood from the power
supply before servicing or cleaning. Our hoods are
equipped with variable speed control blowers.
These units will not function with a single speed
ventilator. All Viking Range ventilator kits are
designed specifically for use with Viking Range
hoods. Use of any non-Viking Range ventilator kit
will void the hood warranty.
READ AND SAVE THESE INSTRUCTIONS
TO REDUCE THE RISK OF FIRE, ELECTRICAL
TO REDUCE THE RISK OF FIRE, ELECTRICAL
TO REDUCE THE RISK OF FIRE, ELECTRICAL
TO REDUCE THE RISK OF FIRE, ELECTRICALTO REDUCE THE RISK OF FIRE, ELECTRICAL
SHOCK, OR INJURY TO PERSONS, OBSERVE
SHOCK, OR INJURY TO PERSONS, OBSERVE
SHOCK, OR INJURY TO PERSONS, OBSERVE
SHOCK, OR INJURY TO PERSONS, OBSERVESHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
THE FOLLOWING:
THE FOLLOWING:
THE FOLLOWING:THE FOLLOWING:
1. Installation work and electrical wiring must
be done by qualified person(s) in
accordance with all applicable codes and
standards, including fire-rated construction.
2. Sufficient air is needed for proper
combustion and exhausting of gases
through the flute (chimney) of fuel burning
equipment to prevent back drafting. Follow
the heating equipment manufacturer’s
guideline and safety standards such as
those published by the National Fire
Protection Association (NFPA), and the
American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
3. When cutting of drilling into wall or ceiling,
do not damage electrical wiring and other
hidden utilities.
4. Ducted fans must always be vented to the
outdoors.
5. WARNING!: To reduce risk of fire, use only
metal ductwork
6. CAUTION!: To reduce risk of fire and to
properly exhaust air, be sure to duct air
outside. Do not vent exhaust air into
spaces within walls or ceilings, or into
attics, crawl spaces, or garages.
7. CAUTION!: To Reduce the Risk of Fire and
Electric Shock, Install this rangehood only
with remote blower models manufactured
by Viking, model numbers –
DEV900/DEV1200, VEV900/VIL1200, OR
integral blowers manufactured by Viking
Range, model numbers –
VINV300/600/1200, or DIL1200. NOTE –
Please refer inside for specific
canopy/blower combinations.
W A R N I N G


Product specificaties

Merk: Viking
Categorie: Afzuigkap
Model: VWH3610S