Viking VMOR506SS Handleiding

Viking Magnetron VMOR506SS

Lees hieronder de 📖 handleiding in het Nederlandse voor Viking VMOR506SS (28 pagina's) in de categorie Magnetron. Deze handleiding was nuttig voor 46 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/28
Installation Guide
Convection Microwave Hood
VMOR506
E1
Mounting Space
This Convection Microwave Hood requires a mounting
space on a wall as shown in figure 1. It is designed to
be used with standard 12-inch wall cabinets.
For proper installation and servicing, a 2-inch space is
necessary between the top of the range backguard and
the bottom of the Convection Microwave Hood.
Wall Construction
This Convection Microwave Hood should be mounted
against and supported by a flat vertical wall. The wall
must be flat for proper installation. If the wall is not flat,
use spacers to fill in the gaps. Wall construction should
be a minimum of 2" x 4" wood studding and 3/8" or more
thick dry wall or plaster/lath. The mounting surfaces must
be capable of supporting a weight of 110 pounds—the
oven and contents—AND the weight of all items which
would normally be stored in the top cabinet above the
unit.
The unit should be attached to a minimum of one 2" x
4" wall stud or two 2" x 3" wall studs.
To find the location of the studs, one of the following
methods may be used:
Use a stud finder, a magnetic device which locates the
nails in the stud.
Use a hammer to tap lightly across the mounting
surface to find a solid sound. This will indicate stud
location.
The center of the stud can be located by probing the
wall with a small nail to find the edges of the stud and
then placing a mark halfway between the edges. The
center of any adjacent studs will normally be 16" or 24"
to either side of this mark.
IMPORTANT–Please Read and Follow!
Please read all instructions thoroughly before installing the Convection Microwave Hood. Two people are
recommended to install this product.
If a new electrical outlet is required, its installation should be completed by a qualified electrician before
the Convection Microwave Hood is installed. See ELECTRICAL GROUNDING INSTRUCTIONS on page 2.
Backguard
At least 2"
15.5"
30"
12"
36" or more
from cooking
surface
72" or more
from floor
1
E2
When the hood is vented to the outside, a hood exhaust
duct is required. All ductwork must be metal; absolutely
do not use plastic duct. Check that all connections are
made securely. Please read the following carefully:
EXHAUST CONNECTION: The hood exhaust has been
designed to connect to a standard 3 ¼" X 10" rectangular
duct. If round duct is required, a rectangular-to-round
adapter must be used.
REAR EXHAUST: If a rear or horizontal exhaust is to be
used, care should be taken to align the exhaust with the
space between the studs, or wall should be prepared
at the time it is constructed by leaving enough space
between wall studs to accommodate exhaust.
MAXIMUM DUCT L ENGT H: For satisfactory air
movement, the total duct length of 3 ¼" X 10" rectangular
or 6" diameter round duct should not exceed 140 feet.
Elbows, adapters, wall caps, roof caps, etc. present
additional resistance to air flow and are equivalent to a
section of straight duct which is longer than their actual
physical size. When calculating the total length, add
the equivalent lengths of all transitions and adapters
plus the length of all straight duct sections. Figure 3
shows the approximate feet of equivalent length of some
typical ductwork parts. Use the values in parentheses for
calculating air flow resistance equivalent, which should
total less than 140 feet.
This appliance must be grounded. This oven is equipped
with a cord having a grounding wire with a grounding
plug. It must be plugged into a wall receptacle that is
properly installed and grounded in accordance with the
National Electrical Code and local codes and ordinances.
In the event of an electrical short circuit, grounding
reduces risk of electric shock by providing an escape
wire for the electric current.
WARNING: Improper use of the grounding plug can
result in a risk of electric shock.
Electrical Requirements
The oven is equipped with a 3-prong grounding plug.
DO NOT UNDER ANY CIRCUMSTANCES CUT OR
REMOVE THE GROUNDING PIN FROM THE PLUG.
DO NOT USE AN EXTENSION CORD. If the power
supply cord is too short, have a qualified electrician or
serviceman install an outlet near the appliance.
The Power Supply Cord and plug must be connected to
a separate 120 Volt AC, 60 Hz, 15 Amp, or more branch
circuit, single grounded receptacle. The receptacle
should be located inside the cabinet directly above
the Convection Microwave Hood mounting location as
shown in figure 2.
NOTE:
If you have any questions about the grounding or
electrical instructions, consult a qualified electrician
or serviceperson.
Neither Viking Range, LLC nor the dealer can accept
any liability for damage to the oven or personal injury
resulting from failure to observe the correct electrical
connection procedures.
Electrical Grounding
Instructions Hood Exhaust Duct
figurefigure
figurefigure
Ground
Receptacle
Opening for
Power Cord


Product specificaties

Merk: Viking
Categorie: Magnetron
Model: VMOR506SS

Heb je hulp nodig?

Als je hulp nodig hebt met Viking VMOR506SS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Magnetron Viking

Handleiding Magnetron

Nieuwste handleidingen voor Magnetron