1
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC
SHOCK, OR INJURY TO PERSONS, OBSERVE
THE FOLLOWING:
1. Use this unit only in the manner intended by the
manufacturer. If you have questions, contact the
manufacturer or your distributor.
2. Before servicing or cleaning unit, switch power off
at service panel and lock the service disconnect-
ing means to prevent power from being switched
on accidentally. When the service disconnecting
means cannot be locked, securely fasten a promi-
nent warning device, such as a tag, to the service
panel.
3. Installation work and electrical wiring must be done
by a qualified person(s) in accordance with all ap-
plicable codes and standards, including fire-rated
construction codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of
fuel burning equipment to prevent backdrafting. Fol-
low the heating equipment manufacturer's guideline
and safety standards such as those published by
the National Fire Protection Association (NFPA),
and the American Society for Heating, Refrigera-
tion and Air Conditioning Engineers (ASHRAE),
and the local code authorities.
WARNING
CAUTION
1. For general ventilating use only. Do not use to
exhaust hazardous or explosive material and
vapors.
2. To avoid motor bearing damage and noisy and/or
unbalanced impellers, keep drywall spray, con-
struction dust, etc. off power unit.
3. Please read specification label on product for
further information and requirements.
4. Electrical circuit, including speed control, (if used),
must be rated 6 AMPS minimum.
Blower Dimensions
28.25 x 24.75 x 7.17
PLAN THE INSTALLATION
1. Locate the ventilator so the length of the duct
run and number of elbows needed are kept to a
minimum.
2. Where possible, ventilator should be centered
between wall studs or roof rafters.
3. Avoid pipes, wires, or other ductwork that may be
running through the wall.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
DEV900 120 5.7 900 10 " DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the out-
doors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
READ AND SAVE THESE INSTRUCTIONS
VIKING MODEL DEV900
EXTERIOR MOUNTED VENTILATOR
FOR USE WITH VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN, DTWS AND
DCIH RANGE HOODS. :-/-2+ 00' 30" TO 42" WIDE, TO 18" HIGH.9"
2
11" dia.
hole
7¼"
1¼"
dia. hole
9
1
/
8
"
10¾"
24¾"
28¼"
Wa ll Stu d
12
7
/
8
"
Wa ll Stu d
REMOVE
SIDING
8½"
Pilot
Hole
Pilot
Hole
OUTSIDE - WALL VIEW
1. Locate the ventilator on the rear slope of the roof.
Place it in a location to minimize duct run. The
location should be free of obstacles (T.V. leads,
electrical lines, etc.). Bear in mind, if the ventilator
top is level with the roof peak, it will not be seen
from the street. Keep this approximate location in
mind as you work from within the attic.
1. Choose a position on the outside wall. Make sure
that no wall studs, pipes or wires run through the
opening area.
PREPARE THE INSTALLATION
LOCATION
ROOF INSTALLATIONS
PREPARE THE INSTALLATION
LOCATION
WALL INSTALLATIONS
ALL INSTALLATIONS
5. For flat roof installations, build a curb that will mount
the ventilator at a minimum pitch of 2/12. See
Figure 2. Discharge end of the ventilator should
be pointed away from prevailing winds.
20½"
10
3
/
8
"
8½"
20¾"
7¼"
1¼"
dia. hole
9
1
/
8
"
Roof Rafter
REMOVE
SHINGLES
11"
dia.
hole
Roof Rafter
Pilot
Hole
Pilot
Hole
OUTSIDE - ROOF VIEW
From inside the attic space:
2. Drill a PILOT HOLE up through the roof, 8½"
from the of a .inside edge ROOF RAFTER
From outside - on the roof:
3. Measure and mark the 20¾" x 20½" rectangle.
Cut and remove only the shingles inside this
rectangle.
4. Measure and mark the 11" DIAMETER HOLE
and the 1¼" DIAMETER HOLE. Cut these holes
all the way through the roof.
Figure 1
PREPARE THE VENTILATOR
1. Unpack the ventilator assembly.
2. Remove the cover and screws.
3. Remove and discard cardboard from ventilator
wheel.
4. Remove the wiring box cover and screws.
5. Attach an appropriate U.L. approved cable con-
nector in the hole at the rear of the wiring box.
From inside the wall:
2. Drill a PILOT HOLE through the wall, 8½" from
the of a inside edge WALL STUD.
From outside - on the wall:
3. Measure and mark the 25" x 29½" rectangle.
Cut and remove only the siding inside this
rectangle.
4. Measure and mark the 11" DIAMETER HOLE
and the 1¼" DIAMETER HOLE. Cut these holes
Figure 3
6¾"
2"
28¼"
24 ¾"
2"
Figure 2
3
1. Remove roofing nails from the upper 2/3 of the
shingles around the cutout area and carefully lift
the shingles to allow the back flashing sheet on
the ventilator housing to fit under them.
2. Center the ventilator ring in the 11" diameter hole,
making sure that the 1-1/4" diameter electrical wir-
ing hole aligns with the hole in the wiring box.
3. Attach the ventilator to the roof with the six screws
provided. All six holes in the back panel must be
filled, or any moisture that may get inside the ven-
tilator housing could leak into the house.
4. Using a good grade of roofing cement, seal all of
the shingles around the housing and flashing sheet
as well as the mounting screw heads.
5. Bring electrical wiring through the hole in the wiring
box and secure it according to local codes.
6. Make the electrical connections with the proper
connector for the type of wiring being used. Con-
nect white to white, black to black, and the green
or bare wire to green. See Figure 4.
7. Replace wiring box cover and screws. Do not pinch
wiring under the cover.
8. Check for free movement of the damper before
installing housing cover and screws.
1. Place a large bead of caulk on the back side of
the housing along the outer edge.
2. Center the ventilator ring in the 11" diameter hole,
making sure that the 1-1/4" diameter electrical
wiring hole aligns with the hole in the wiring box.
3. Attach ventilator to the wall with the six screws
provided. All six holes in the back panel must
be filled, or any moisture that may get inside the
ventilator housing could leak into the house.
4. Using a good grade of caulk, seal all around the
mounting screw heads.
5. Bring electrical wiring through the hole in the wiring
box and secure it according to local codes.
6. Make the electrical connections with the proper
connector for the type of wire being used. Connect
white to white, black to black, and green or bare
wire to green. See Figure 4.
7. Replace wiring box cover and screws. Do not pinch
wiring under cover.
8. Check for free movement of the damper before
installing housing cover and screws.
9. Top and side flanges of the back plate may be
covered with trim strips. Do not block grille open-
ing at bottom with trim. It will adversely affect
performance of the ventilator.
INSTALL THE VENTILATOR
ROOF INSTALLATIONS
INSTALL THE VENTILATOR
WALL INSTALLATIONS
Figure 4
120 VAC
LINE IN
BLACK
TO
BLACK
WHITE
TO
WHITE
GREEN
TO
GREEN