Viking DEV1200S Handleiding

Viking Afzuigkap DEV1200S

Lees hieronder de 📖 handleiding in het Nederlandse voor Viking DEV1200S (8 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 14 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
READ AND SAVE THESE INSTRUCTIONS
MODEL DEV1200
EXTERIOR MOUNTED VENTILATOR
FOR USE WITH VIKING VCWH, VICH, DBCV, DICV, DCWH, DCWL, DCWN,
DTWS AND DCIH RANGE HOODS. 30" TO 66" WIDE, 9" TO 18" HIGH.
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manu-
facturer. If you have questions, contact the manufac-
turer or your distributor.
2. Before servicing or cleaning unit, switch power off at
service panel and lock the service disconnecting means
to prevent power from being switched on accidentally.
When the service disconnecting means cannot be locked,
securely fasten a prominent warning device, such as a
tag, to the service panel.
3. Installation work and electrical wiring must be done by a
qualified person(s) in accordance with all applicable
codes and standards, including fire-rated construction
codes and standards.
4. Sufficient air is needed for proper combustion and
exhausting of gases through the flue (chimney) of fuel
burning equipment to prevent backdrafting. Follow the
heating equipment manufacturer's guideline and safety
standards such as those published by the National Fire
Protection Association (NFPA), and the American Soci-
ety for Heating, Refrigeration and Air Conditioning Engi-
neers (ASHRAE), and the local code authorities.
CAUTION
1. For general ventilating use only. Do not use to exhaust
hazardous or explosive material and vapors.
2. To avoid motor bearing damage and noisy and/or unbal-
anced impellers, keep drywall spray, construction dust, etc.
off power unit.
3. Please read specification label on product for further informa-
tion and requirements.
4. Electrical circuit, including speed control, (if used), must be
rated 6 AMPS minimum.
PLAN THE
INSTALLATION
1. Locate the ventilator so
the length of the duct run
and number of elbows
needed are kept to a mini-
mum.
2. Where possible, ventilator
should be centered be-
tween wall studs or roof
rafters.
3. Avoid pipes, wires, or other
ductwork that may be run-
ning through the wall.
ALL INSTALLATIONS
MODEL VOLTS AMPS CFM DUCT SIZE
DEV1200 120 3.0 1200 10" DIA.
SPECIFICATIONS
INSTALLER: Leave This Manual With The Homeowner
HOMEOWNER: Use And Care Information On Page 4
TYPICAL ROOF MOUNTED INSTALLATION TYPICAL WALL MOUNTED INSTALLATION
5. When cutting or drilling into wall, or ceiling, do not
damage electrical wiring or other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. To reduce risk of fire, use only metal ductwork.
8. This unit must be grounded.
WARNING
MODEL DEV1200
EXTERIOR VENTILATOR
10" ROUND
DUCT
SOFFIT
WALL HOOD
CANOPY
(island canopy available)
MODEL
DEV1200
EXTERIOR
VENTILATOR
10" ROUND DUCT
SOFFIT
10" ROUND ELBOW
WALL HOOD
CANOPY
(island canopy available)
Blower Dimensions
22 x 30.828 x 12.724
11" dia.
11" dia.
11" dia.
11" dia.
hole
hole
hole
hole
22"
22"
22"
22"
Guide hole
Guide hole
Guide hole
Guide hole
(centered between studs)
(centered between studs)
(centered between studs)
(centered between studs)
22"
29½"
29½"
29½"
29½"29½"
1411
/
16 "
11
11
11
1113
13
13
13
/
/
/
/
16
16
16
16"
"
"
"11 13
/
16"
17"
17"
17"
17"
Wall Stud
Wall Stud
11" dia.
hole
17"
1¼" dia.
1¼" dia.
1¼" dia.
1¼" dia. hole
hole
hole
hole1¼" dia. hole
3
"
Ø
Ø
Ø
ØØ
Ø
Ø
Ø
ØØ
REMO
REMO
REMO
REMOVE
VE
VE
VE
SIDING
SIDING
SIDING
SIDING
REMOVE
SIDING
Guide hole
(centered between studs)
1. Choose a position on the outside wall. Make sure that no
wall studs, pipes or wires run through the opening area.
2. From inside, mark and drill a guide hole centered
between wall studs.
PREPARE THE INSTALLATION
LOCATION
ROOF INSTALLATIONS
22" 2"
7"
29-1/2"
2"
WALL INSTALLATIONS
1. Locate the ventilator on the rear slope of the roof. Place
it in a location to minimize duct run. The location should
be free of obstacles (T.V. leads, electrical lines, etc.). If
the ventilator top is level with the roof peak, it will not be
seen from the street. Keep this approximate location in
mind as you work from within the attic.
2. Mark and drill a guide hole centered between roof
rafters.
2
3. From the outside, use the guide hole as a starting point
to lay out the installation:
A. Use a T-square to measure 913/16" to the left of the
guide hole, then up 1211/16" to locate the top-left
corner of the layout.
B. Starting from the top-left corner, mark the rectan-
gular cutout (18" W x 20½" H) and remove only the
shingles in this area.
C. Mark an 11" diameter hole centered on the guide
hole. Cut this hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole through the roof
board(s) where shown.
4. For flat roof installations, build a curb that will mount the
ventilator at a minimum pitch of 2/12. Discharge end of the
ventilator should be pointed away from prevailing winds.
PREPARE THE INSTALLATION
LOCATION
11" dia.
11" dia.
11" dia.
11" dia.
hole
hole
hole
hole
20½"
20½"
20½"
20½"
11" dia.
hole
1"
Ø
Ø
Ø
Ø
Ø
9
9
9
9
11
11
11
11
/
/
/
/
16
16
16
16"
"
"
"
20½"
Ø
Ø
Ø
Ø
Ø
15"
9
13
/
16"
18"
18"
18"
18"
12
12
12
12 11
11
11
11
/
/
/
/
16
16
16
16"
"
"
"
1¼" dia.
1¼" dia.
1¼" dia.
1¼" dia. hole
hole
hole
hole
1¼" dia. hole
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
Roof Rafter
REMO
REMO
REMO
REMOVE SHINGLES
VE SHINGLES
VE SHINGLES
VE SHINGLES
REMOVE SHINGLES
Roof Rafter
Guide hole
Guide hole
Guide hole
Guide hole
(centered
(centered
(centered
(centered
between rafters)
between rafters)
between rafters)
between rafters)
Guide hole
(centered
between rafters)
12 11
/
16"
18"
3. From the outside, use the guide hole as a starting point
to lay out the installation:
A. Use a T-square to measure 1113/16" to the left of the
guide hole, then up 1411/16" to locate the top-left
corner of the layout.
B. Starting from the top-left corner, mark the rectan-
gular cutout (22" W x 29½" H) and remove only the
siding in this area.
C. Mark an 11" diameter hole centered on the guide
hole. Cut this hole through the roof board(s).
D. Mark and cut a 1¼" diameter hole through the roof
board(s) where shown.
1. Remove the cover and screws.
2. Attach an appropriate U.L. approved cable connector
in the hole at the rear of the wiring box.
3. Remove roofing nails from shingles around the TOP and
SIDES of the cutout area only.Carefully lift the shingles
to allow the back flashing sheet on the ventilator housing
to fit under them.
4. Center the ventilator ring in the 11" diameter hole, making
sure that the 1¼" diameter electrical wiring hole aligns
with the hole in the wiring box.
5. Attach the ventilator to the roof with six (6) screws
provided. It is recommended that the screws be located
inside the ventilator housing. Drill pilot holes if necessary.
6. Using a good grade of roofing cement, seal all of the
shingles around the housing and flashing sheet as well
as the mounting screw heads.
7. Bring electrical wiring through the hole in the wiring box
and secure it according to local codes.
8. Make the electrical connections with the proper connec-
tor for the type of wiring being used. Connect black to
black, white to blue, and the green or bare wire to
grounding screw.
9. Replace cover and screws. Do not pinch wiring under the
cover.
10. Make sure damper opens and closes freely.
1. Place a large bead of caulk on the back side of the
housing all along the outer edges.
2. Center the ventilator ring in the 11" diameter hole, making
sure that the 1¼" diameter electrical wiring hole aligns
with the hole in the wiring box.
3. Attach ventilator to the wall with the six (6) screws
provided. It is recommended that the screws be located
inside the ventilator housing. Drill pilot holes if neces-
sary.
4. Using a good grade of caulk, seal all around the
mounting screw heads.
5. Bring electrical wiring through the hole in the wiring box
and secure it according to local codes.
INSTALL THE VENTILATOR
ROOF INSTALLATIONS
INSTALL THE VENTILATOR
WALL INSTALLATIONS
3
6. Make the electrical connections with the proper connec-
tor for the type of wire being used. Connect black to
black, white to blue, and green or bare wire to grounding
screw.
7. Replace cover and screws. Do not pinch wiring under
cover.
8. Make sure damper opens and closes freely.
9. Top and side flanges of the back plate may be covered
with trim strips. Do not block grille opening at bot-
tom with trim. It will adversely affect performance of the
ventilator.
BLACK
TO
BLACK
120 VAC
LINE
IN
WHITE
TO
BLUE
GROUND
TO
GROUNDING
SCREW
BLACK
TO
BLACK
120 VAC
LINE
IN
WHITE
TO
BLUE
GROUND
TO
GROUNDING
SCREW


Product specificaties

Merk: Viking
Categorie: Afzuigkap
Model: DEV1200S

Heb je hulp nodig?

Als je hulp nodig hebt met Viking DEV1200S stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Viking

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap