Venmar Jazz VJ603302SS Handleiding

Venmar Afzuigkap Jazz VJ603302SS

Lees hieronder de đź“– handleiding in het Nederlandse voor Venmar Jazz VJ603302SS (10 pagina's) in de categorie Afzuigkap. Deze handleiding was nuttig voor 13 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/10
VJ603302SS CHIMNEY RANGE HOOD
INSTALLATION INSTRUCTIONS
INTENDED FOR DOMESTIC COOKING ONLY
INSTALLER: LEAVE THIS MANUAL WITH HOMEOWNER.
HOMEOWNER: USE AND CARE INFORMATION ON PAGES 8 9.AND
READ AND SAVE THESE INSTRUCTIONS
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville QC J2C 7W9 1-800-567-3855
REGISTER YOUR PRODUCT ONLINE AT: www.bnv.ca
For additional information - visit www.venmar.ca
09070 rev. 09
! !
HB0129
2
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR
INJURY TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer.
If you have questions, contact the manufacturer at the address
or telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service
panel and lock service disconnecting means to prevent
power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a
prominent warning device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by
qualified personnel in accordance with all applicable codes
and standards, including fire-rated construction codes and
standards.
4. Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment
to prevent backdrafting. Follow the heating equipment
manufacturer’s guidelines and safety standards such as
those published by the National Fire Protection Association
(NFPA) and the American Society for Heating, Refrigeration
and Air Conditioning Engineers (ASHRAE) and the local code
authorities.
5. When cutting or drilling into wall or ceiling, do not damage
electrical wiring and other hidden utilities.
6. Ducted fans must always be vented to the outdoors.
7. Do not use this unit with any solid-state speed control device.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
10. To provide protection against electric shock, connect to
properly grounded outlets only.
11. When applicable local regulations comprise more
restrictive installation and/or certification requirements,
the aforementioned requirements prevail on those of this
document and the installer agrees to conform to these at his
own expenses.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
a) Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
b) Always turn hood ON when cooking at high heat or when
flambeing food (i.e.: CrĂŞpes Suzette, Cherries Jubilee,
Peppercorn Beef Flambé).
c) Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan, filters or in exhaust ducts.
d) Use proper pan size. Always use cookware appropriate for the
size of the surface element.
1. For indoor use only.
2. For general ventilating use only. Do not use to exhaust
hazardous or explosive materials and vapors.
3. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
4. Your hood motor has a thermal overload which will
automatically shut off the motor if it becomes overheated. The
motor will restart when it cools down. If the motor continues to
shut off and restart, have the hood serviced.
5. The minimum hood distance above cooktop must not be less
than 26". For best capture of cooking impurities, the bottom
of the hood should be at a maximum of 30" above cooking
surface. For a gas range, the bottom of the hood MUST NOT
BE LESS than 30" above cooktop.
6. Two installers are recommended because of the large size and
weight of this unit.
7. To reduce the risk of fire and to properly exhaust air, be sure to
duct air outside — Do not exhaust air into spaces within walls
or ceiling or into attics, crawl space or garage.
8. Because of the high exhausting capacity of this unit, you
should make sure enough air is entering the house to replace
exhausted air by opening a window close to or in the kitchen.
9. Please read specification label on product for further
information and requirements.
WARNING
!
CAUTION
WARNING
!
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE
EVENT OF A RANGE TOP GREASE FIRE, OBSERVE
THE FOLLOWING*:
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet or
metal tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. IF THE FLAMES DO NOT GO OUT IMMEDIATELY,
EVACUATE AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels —
This could cause a violent steam explosion.
4. Use an extinguisher ONLY if:
A. You own a Class ABC extinguisher and you know how to
operate it.
The fire is small and contained in the area where it started.B.
The fire department has been called.C.
You can fight the fire with your back to an exit.D.
* Based on “Kitchen Fire Safety Tips” published by NFPA.
3
WARRANTY
VENMAR JAZZ RANGE HOOD
1-YEAR LIMITED WARRANTY
Venmar Ventilation ULC warrants to the original consumer purchaser of its products, that such products will be free from defects
in materials or workmanship for a period of one (1) year from date of original purchase. This warranty includes in-home service.
THERE ARE NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. VENMAR VENTILATION ULC WILL NOT BE HELD
RESPONSIBLE FOR ANY CLAIMS OVER THE ORIGINAL PURCHASE PRICE OF A VENMAR JAZZ RANGE HOOD, NOR HELD
RESPONSIBLE FOR SUBSEQUENT DAMAGE OR INCIDENT.
During this one-year period, Venmar Ventilation ULC will, at its option, repair or replace, without charge, any product or part which is
found to be defective under normal use and service. THIS WARRANTY DOES NOT EXTEND TO BULBS, FUSE, FILTERS, DUCTS,
ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING. This warranty does not cover a) normal maintenance and
service b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repairs made by
other than Venmar Ventilation ULC, or c) a faulty installation or installation contrary to recommended installation instructions.
Warranty service is to be completed by an authorized Service Center designated by Venmar Ventilation ULC. Where applicable, in-home
service will be made available only in areas where a contracted service provider offers service. If in-home service is not available, the
product will be repaired or replaced, at Venmar Ventilation ULC’s discretion, by the nearest authorized service provider. The unit removal
and reinstallation works are under the customer responsibility, and Venmar Ventilation ULC cannot be charged for them.
The duration of any implied warranty is limited to the 1-year period as specified for the express warranty. Some provinces do not allow
limitation on how long an implied warranty lasts, so the above limitation may not apply to you. VENMAR VENTILATION ULC OBLIGATION
TO REPAIR OR REPLACE AT VENMAR VENTILATION ULC OPTION, SHALL BE THE PURCHASER’S SOLE AND EXCLUSIVE
REMEDY UNDER THIS WARRANTY. VENMAR VENTILATION ULC SHALL NOT BE LIABLE FOR INCIDENTAL, CONSEQUENTIAL
OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. SOME PROVINCES
DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION
OR EXCLUSION MAY NOT APPLY TO YOU.
This warranty gives you specific legal rights and you may also have other rights, which vary from one province to another. This warranty
supersedes all prior warranties. To contact Venmar Ventilation ULC Warranty Service call 1-800-567-3855 (in Canada). In order to qualify
for a warranty claim, the owner of a Venmar Jazz range hood must have the model and serial number along with a proof of the original
purchase date. At the time of requesting service, describe the nature of any defect in the product or part.
Venmar Ventilation ULC, 550 Lemire Blvd., Drummondville, Quebec CANADA J2C 7W9
Tel.: 1-800-567-3855 Fax: 819-475-2660
www.venmar.ca
1. INSTALL DUCTWORK ..............................................................................................................................................................4
2 MEASURE INSTALLATION ........................................................................................................................................................4
3 PREPARE INSTALLATION .........................................................................................................................................................5
4. WIRING INSTALLATION ...........................................................................................................................................................5
5. INSTALL HOOD MOUNTING BRACKET .........................................................................................................................................6
6. INSTALL UPPER FLUE MOUNTING BRACKET .................................................................................................................................6
7. REMOVE GREASE FILTERS .....................................................................................................................................................6
8 INSTALL HOOD .....................................................................................................................................................................7
9. REINSTALL GREASE FILTERS ...................................................................................................................................................8
10. LIGHT BULBS ......................................................................................................................................................................8
11. OPERATION .....................................................................................................................................................................8-9
12. CARE .............................................................................................................................................................................9
13. REPLACEMENT PARTS ......................................................................................................................................................... 10
TABLE OF CONTENTS


Product specificaties

Merk: Venmar
Categorie: Afzuigkap
Model: Jazz VJ603302SS

Heb je hulp nodig?

Als je hulp nodig hebt met Venmar Jazz VJ603302SS stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Afzuigkap Venmar

Handleiding Afzuigkap

Nieuwste handleidingen voor Afzuigkap