Bekijk gratis de handleiding van Vemer RX4-8A (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 45 mensen en kreeg gemiddeld 4.9 sterren uit 23 reviews. Heb je een vraag over Vemer RX4-8A of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
User Manual
REMOTE ACTUATOR MODEL RX4-8A
Read all the instructions carefully
V3IS00370-012
Mod. RX4-8A
 TheremoteactuatorRX4-8Aisanindependentlymountedautomaticcontrolforheating
andairconditioningapplications,designedforcomunicationswithAthena programmable
thermostat (radio and bus) and Klio digital thermostat (radio).
 Itprovidesatype1Bactionsanditisdesignedforhouseholdandsimilarusewith
overvoltage category III and normal pollution level (EN 60730-1).
SAFETY WARNINGS
During product installation and operation, the following safety instructions should be
respected:
1) The instrument should be installed by qualified personnel
2) Before touching the terminals, make sure there is no power supply to the electric wires
3) Do not power or connect the instrument if any part of it is damaged
4) Follow the connection diagrams descripted on this manual and over the instrument
5) The electrical system of the building in which the instrument is to be installed should have
a switch and a protective device against over-currents.
6) The instrument must be installed and activated in compliance with current electric systems
standards
7) After installation, inaccessibility to the connection terminals without appropriate tools
must be granted.
Code Model Description
VN943700 RX4-8A Remote actuator
TECHNICAL SPECIFICATIONS
• Powersupply:230VAC(-15%/+10%)50/60Hz
• Outputs:
 –4relays1changeovercontact:8A/250VAC(resistiveload)
 –serialportfor networkconnection(RS-485)Athena
– external antenna (on request)
• Operatingtemperature:0°C÷50°C
• Storagetemperature:-10°C÷65°C
• Enclosure:2moduleDIN,RAL7035gray
• Protectiondegree:IP20(IP40whencorrectlyinstalledinanelectricalpanel)
OPERATION
DESCRIPTION AND CONTROLS
 GreenLEDoperationfunction
 RedLEDsrelayfunction
 ResetandprogrammationSETBUTTON
FUNCTION
• Instartingphase,theredLEDsashestwiceforsomeseconds(switchingon-sequence).
• Attheendoftheswitchingon-sequence,thegreenLEDsignalnormaldeviceoperationand
theredLEDsrelaystatus(lighton=relayON).
• Theremotecontrol(relaycommutationON/OFF)requestfromKlio digital thermostat and
Athenaprogrammablethermostattakeplaceonlyafterchannelsetting-up.
Network example
• Theradioconnectionbreakdownformorethan15minutesbetweenthetransmitter
andthereceiverdisconnectstherelay/relaysandtheredLED/LEDslightened.Restoreof
operations is automatic.
Channel setting-up
– Duringnormaloperation,presstheSETkey-buttonforalmostthreesecondstoenterin
modality-conguration.GreenLEDswitch-off,redLEDash.PresstheSETkey-button
to select the output relay.
– Theinstrumentkeeponmodality-congurationforamaximumof60secondswithinthe
actuator should receive a string configuration (see Athena Klioand/or instructionsfor
string start-up modality).
– Onreceiptofstring,channelissetted-upandtheactuatorisonstandardfunctioning.
– Forre-settingup,repeatingtheprocedure.
• Toresetchannelsetting-up,plugintocongurationmodalitywithSETbutton,thenpush
thesameoneforthreesecondsandwaitforgreenledswitchingon.
 Anewchannelsettingupcancelsthepreviousconguration.
SERIAL OUTPUT
 RX4-8AfeaturesaninsulatedserialoutputRS485forcommunication.Itispossibleto
connectupto64instrumentsuptoamaximumdistanceof40m.
Note: It is possible to connect a remote actuator with different programmable
thermostats . In this case it is necessary to configure different zones Athena
for each . Exemple: 2 Athena Athena are connected with a remote actuator:
if Z1 is selected in the first , then Z2, Z3 or Z4 must be selected in the Athena
second Athena.
STANDARDS REFERENCE
ConformitytotheEUdirectives:
2006/95/EC(LowVoltage)
2004/108/CE(ElectromagneticCompatibility)
isdeclaredwithreferencetothefollowingharmonizedstandard:
Safety:EN 60730-1
Electromagneticcompatibility:EN 301 489-1/3 EN 300 220-3and
Athena.temp
Actuator
Boiler
ATHENA
+Tx.Athena
Bedroom
Bathroom
Living room
KitchenEntrance
Athena.temp
Athena.temp
RF
BUS
Controlof4zonesbytheAthena programmable thermostat
- Living programmable thermostatroom/kitchenProbe:builtintoAthena
- BedroomProbe:remote,connectiontoAthenaviabus485
- Bathroomprobe:remote,connectionto viabus485Athena
- Entranceprobe:remote,connectionto viabus485Athena
Theair-conditioningequipmentiscontrolledbyAthenaprogrammablethermostatbymeansofa
remote actuator (RX4-8A)viaRFand/or485bus.
Dimensions (A)
Connection diagram (B)
Description (C)
8787
60
65
45
7272
8 A / 250 V ~
5
0
-
6
0
H
z
8 A / 250 V ~ 8 A / 250 V ~ 8 A / 250 V ~
Out 1
Out 2 Out 3 Out 4
2
3
0
V
~


Product specificaties