Bekijk gratis de handleiding van Vemer RX1-8A (1 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 59 mensen en kreeg gemiddeld 5.0 sterren uit 30 reviews. Heb je een vraag over Vemer RX1-8A of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/1
Mod. RX1-8A
Dimensions
Connection diagram
35.6
87.8
60
55
45
421
5 6 87
2
3
0
V
~
5
0
-
6
0
H
z
8A / 250V CA
3
Out
Connection examples
M
L
N
NA
C
NC
Out
L
N
NA
C
NC
Out
LOAD
Circulation pumps,
burners, solenoid valves.
Motor-operated valves.
User Manual
REMOTE ACTUATOR MODEL RX1-8A
Read all the instructions carefully
Theremoteactuator
RX1-8A
isanindependentlymountedautomaticcontrolfor
heatingandairconditioningapplications,designedforradiocomunicationswith
Athena
programmable thermostat and
Klio
digital thermostat
.
Itprovidesatype1Bactionsanditisdesignedforhouseholdandsimilarusewith
overvoltage category III (EN 61010-1) and normal pollution level (EN 60730-1).
SAFETY WARNINGS
During product installation and operation, the following safety instructions
should be respected:
1) The appliance should only be installed by technical person support
2) Take out power supply during product installation
3) Do not power or connect the instrument if any part of it is damaged
4) Follow the connection diagrams descripted on this manual and over the
product
Code Model Description
VE015400 RX1-8A Remote actuator
CARACTÉRISTIQUES TECHNIQUES
• Powersupply:230VAC(-15%/+10%)50/60Hz
• Outputs:
 -1relay8A250VAC(resistiveload)
- external antenna (on request)
• Operatingtemperature:0°C÷50°C
• Storagetemperature:-10°C÷65°C
• DIN-railmounting
• Protectiondegree:IP40
USE
DISPLAY AND CONTROLS
1–GreenLEDoperationfunction
2–RedLEDrelayfunction
3–ResetandprogrammationSETBUTTON
OPERATION
• Instartingphase,theredLEDashesestwicefor
someseconds(switchingon-sequence).
• Attheendoftheswitchingon-sequence,the
greenLEDsignalnormaldeviceoperationand
theredLEDrelaystatus(lighton=relayON).
• Theremotecontrol(relaycommutationON/
OFF)requestfromKlio digital thermostat and
Athena programmable thermostat take place
onlyafterchannelsetting-up.
• Theradioconnectionbreakdownformorethan
15minutesbetweenthetransmitterandthe
receiverdisconnectstherelayandtheredLED
lightened.Restoreofoperationsisautomatic.
Channel setting-up
°  Duringnormaloperation,presstheSETkey-buttonforalmostthreesecondstoenter
inmodality-conguration.GreenLEDswitch-off,redLEDash.
° Theappliancekeeponmodality-congurationforamaximumof60secondswithin
theactuatorshouldreceiveastringconguration(seeAthenaand/orKlioinstructions
forstringstart-upmodality).
° Onreceiptofstring,channelissetted-upandtheactuatorisonstandardfunctioning.
° Forre-settingup,repeatingtheprocedure.
• Toresetchannelsetting-up,plugintocongurationmodalitywithSETbutton,thenpush
thesameoneforthreesecondsandwaitforgreenledswitchingon.Anewchannelsetting
up cancels the previous configuration.
STANDARDS REFERENCE
ConformitywithEUDirectives:
2006/95/EC (LowVoltage)
2004/108/EC (E.M.C.)
isdeclaredwithreferencetothefollowingstandards:
Safety: EN 60730-1
Electromagnetic compatibility: EN301489-1/3andEN300220-3
1
3
2
CLOSE
OPEN
V3IS00378-010-102009