Bekijk gratis de handleiding van Velleman VM204 (24 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 323 mensen en kreeg gemiddeld 5.0 sterren uit 162 reviews. Heb je een vraag over Velleman VM204 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/24

W W W . V E L L E M A N P R O J E C T S . E U
USER MANUAL DECEMBER 2016
E T H E R N E T R E L A Y C A R D
V M 2 0 4

Table of contents
Let’s get started!
CAUTION
uDo not connect external voltage to the inputs because this will destroy the VM204!
Take care not to exceed the relay rated voltage and current!
u
Changing the credentials will reboot the VM204 and all relays will be deactivated, make sure no
machines are connected while doing this!
u
If you click the save and reboot button, the VM204 will deactivate all relays. The webserver
will restart with the new port and/or IP so the current webpage will not work. Browse to the
new page with the correct port and/or IP.
u
1. Connecting the VM204 4
1.1UsingtheiOSandAndroidappforthersttime 4
1.2UsingthePCapplicationforthersttime 8
2. Controlling the VM204 10
2.1 Relay 10
2.2 Input 11
2.3 Analog input 12
2.4 API 13
3. Editing the VM204 14
3.1 Credentials 14
3.2 Network settings 14
3.3 Email settings 15
3.4 I/O settings 15
3.5Noticationsettings 17
3.6API 18
3.7APIreferences 18
3.8About 18
Introduction 3
4. Upgrading the rmware 21
2.5 Factory reset 13

3VM204USER MANUAL
Introduction to the VM204
The VM204 is an Ethernet controlled board with 4 relay contacts, 4 digital inputs
and 1 analog input. You can connect these I/O’s to different devices and control
or check them from anywhere you like using your PC, smartphone or tablet. The
VM204canalsosendemailnoticationswhenthestatusofaninputchangesand
features an embedded webserver.
If you wish to control your VM204 with your smartphone or tablet, free apps are
available for Android® and iOS®.
Max.30V / 2A
4 relay contacts
Analog
input
- +
Factory
reset
SPI
UART
Status
LEDs
Reset
button
Power
LED
Ethernet
connector
USB (5 V)
power
supply
input
PVM204’5
VELLEMAN NV
892N-1AC-C 5V-DC
892N-1AC-C 5V-DC
892N-1AC-C 5V-DC
892N-1AC-C 5V-DC
PIC32MX695F
GND
INPUT4
INPUT3
INPUT2
INPUT1
GND
GND
GND
Relay status LEDs
For inductive loads,
add optional VDRs
to protect relays
(e.g., Velleman
VDR250)
Digital inputs
accept dry
contact or open
collector
INPUTx
GND
Digital input
test buttons
& status LEDs
Product specificaties
Merk: | Velleman |
Categorie: | Niet gecategoriseerd |
Model: | VM204 |
Heb je hulp nodig?
Als je hulp nodig hebt met Velleman VM204 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Velleman
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
24 Mei 2025
25 Maart 2025
25 Maart 2025
25 Maart 2025
25 Maart 2025
25 Maart 2025
Handleiding Niet gecategoriseerd
- Barazza
- Maytronics
- Global Water
- Hagor
- Cascade Audio Engineering
- Cablexpert
- Adidas
- Petri
- Westland
- Maximum
- MID49
- Focal
- Candy
- Jack Wolfskin
- Everdure
Nieuwste handleidingen voor Niet gecategoriseerd
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025
30 Juli 2025