Uni-T UT131B Handleiding

Uni-T Multimeter UT131B

Bekijk gratis de handleiding van Uni-T UT131B (72 pagina’s), behorend tot de categorie Multimeter. Deze gids werd als nuttig beoordeeld door 65 mensen en kreeg gemiddeld 4.8 sterren uit 33 reviews. Heb je een vraag over Uni-T UT131B of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/72
Eng l i shSve n skaNo r skSuo m iDe u tsc h
UNI-T UT131B Multimeter
Multimeter UNI-T UT131B
UNI-T UT131B multimeter
Yleismittari UNI-T UT131B
Art.no.
41-1599 Ver. 20201120
UT131B
HOLD/SEL
FUSED
250V Max
10 sec Max
FUSED
200mA Max
CAT II 250V
OFF
20M
200k
20k
10 12V 9V
1.5V
2000
200
200
V
V
200m
2000m
200
20
250
250
200μ
200m
2
Eng l i sh
UNI-T UT131B Multimeter
Art.no: 41-1599
Please read theentire instruction manual before using theproduct and then
save it for future reference. We reserve theright for any errors in text or
images and any necessary changes made to technical data. In theevent of
technical problems or other queries, please contact our Customer Services
(see address details on theback).
Information about themeter
Themultimeter has been designed and tested in accordance with
therequirements for installation category II up to nominal voltages of
250V and acontamination level of2.
Categorisation
Meters are divided into different categories depending on theelectrical
environment in which they are to be used and how safe/protective they are
in theevent of avoltagesurge.
Themeter label should indicate which category it belongs to.
Thecategorisation also determines how safe theinstrument is with regards
to any overvoltage which could represent ahazard for theuser.
Thecategorisation is described briefly below:
In theevent of avoltage surge in theelectricity grid (atransient from
alightning strike, etc.), therisk will be greatest where themains supply
cable enters thebuilding, for example. Further inside thebuilding,
theresistance (impedance) in thecables will increase and connected
devices will reduce and dissipate theovervoltage. Themeter category will
therefore determine which electrical environment theinstrument is designed
to be usedin.
3
Eng l i sh
Thecategories which meters are divided into are as follows:
For measuring electronics and products that have inbuilt Category I:
protection against voltage surges.
For measuring single-phase equipment which is fed via Category II:
thebuilding’s electrical power supply system. Bothplug-connected and
permanently installed.
For measuring thebuilding’s electrical systems. Category III:
Permanently installed cables, sockets, fuse boxes and switchgear
cabinets. Three-phase distribution (allpower supply cables and three-
phase equipment, machinery and appliances).
Category IV: Three-phase at primary level and all conductors for
outdoor use.
This multimeter belongs to installation category II and is intended for
measuring voltages of up to 250V in single-phase products. Themeter
must not be used for measuring three-phase products, three-phase
conductors or switchgear cabinets even if thenominal voltage does not
exceed 250V.
Contamination level
Themeter is designed for use in environments in which contaminants
which do not conduct electricity are present. Withtheexception that
temporary conductor contamination can occur due to condensation.
Examples of environments with contamination level 2 are home
environments in dry rooms, offices, test stations and laboratories. Inother
words, rooms which have anormal indoor climate.
Themeter must not be used or stored in rooms where it could be exposed
to electrically conductive contaminants in any form (solid, liquid or gas).
Themeter should for example not be exposed to relative humidities in
excess of 75% or used in unheated rooms and must not be used in
wetrooms or outdoors where it could getwet.
It is not intended for use with electrical equipment which is used in industry
or agriculture.