Tripp Lite PDUV15-48 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite PDUV15-48 (16 pagina's) in de categorie Stekkerdoos. Deze handleiding was nuttig voor 28 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/16
1
Rack PDU
Important Safety Instructions 2
Important Warnings 2
Installation 3
Features 4
Warranty & Product Registration 5
Español 6
Français 11
Metered Models:
PDUMV15
(Series Number: AGIB6098)
PDUMV20
(Series Number: AGIB6099)
Basic Models:
PDUV15
(Series Number: AGIB6098)
PDUV20
(Series Number: AGIB6099)
PDUV20-60
(Series Number: AGIB6099)
PDUV15-48
(Series Number: AGIB6098)
Owner’s Manual
WARRANTY REGISTRATION
Register your product today and be
automatically entered to win an ISOBAR®
surge protector in our monthly drawing!
tripplite.com/warranty
1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/support
Copyright © 2020 Tripp Lite. All rights reserved.
20-09-044-93364D.indb 1
2
SAVE THESE INSTRUCTIONS
This manual contains instructions and warnings that should be
followed during the installation, operation and storage of this
product. Failure to heed these instructions and warnings will
void the product warranty.
• The PDU provides the convenience of multiple outlets, but DOES NOT provide surge or line
noise protection for connected equipment.
• The PDU is designed for indoor use only, in a controlled environment, away from excess
moisture, temperature extremes, conductive contaminants, dust or direct sunlight.
• Keep indoor ambient temperature between 32°F and 77°F (0°C and 25°C).
• The PDU must be installed by a qualified technician only.
• Do not attempt to mount the PDU to an insecure or unstable surface.
• Install in accordance with National Electrical Code standards. Be sure to use the proper
overcurrent protection for the installation, in accordance with the plug/equipment rating.
• Connect the PDU to an outlet that is in accordance with your local building codes and that
is adequately protected against excess currents, short circuits and earth faults.
• The electrical outlets supplying power to the equipment should be installed near the
equipment and easily accessible.
• Do not connect the PDU to an ungrounded outlet or to extension cords or adapters that
eliminate the connection to ground.
• Be sure to provide a local disconnect device on any models that are permanently installed
without a plug that is easily accessible.
• Never attempt to install electrical equipment during a thunderstorm.
• Individual equipment connected to the PDU should not draw more current than the
individual PDU’s outlet’s rating.
• The total load connected to the PDU must not exceed the maximum load rating for the
PDU.
• Do not attempt to modify the PDU, input plugs or power cables.
• Do not drill into or attempt to open any part of the PDU housing. There are no user-
serviceable parts inside.
• Do not attempt to use the PDU if any part of it becomes damaged.
• Use of this equipment in life support applications where failure of this equipment can
reasonably be expected to cause the failure of the life support equipment or to significantly
affect its safety or effectiveness is not recommended.
Important Safety Instructions
Important Warnings
20-09-044-93364D.indb 2
3
1A
0U Rack Configuration. Attach the three mounting
clips supplied with the PDU to the rack enclosure using
the included hardware. The mounting clips should be
attached along a vertical plane at equidistant points
which roughly correspond to the center and ends of the
PDU. The exact mounting configuration may vary
depending on the rack and enclosure. If possible, use
pre-existing mounting points within the enclosure.
1B
Wall or Under-Counter Configuration. Attach the
three mounting clips supplied with the PDU to a wall or
similar flat, secure surface using the included hardware.
The mounting clips should be attached along a vertical
or horizontal plane at equidistant points which roughly
correspond to the center and ends of the PDU. If
possible, use pre-existing mounting points. WARNING:
Do not attempt to mount the PDU with the outlets
facing downward; the mounting clips are not
designed to support the weight of the PDU in that
manner.
1C
0U Rack Configuration. Attach the included mounting
buttons to the PDU. Position the PDU as desired in the
rack enclosure, align the buttons with the rack
mounting slots, and slide the PDU into position. Go to
step
3
.
Note: Regardless of configuration, the user must determine the
fitness of hardware and procedures before mounting. The PDU
and included hardware are designed for common rack and rack
enclosure types and may not be appropriate for all applications.
2
Attach the PDU to the mounting clips. Using an
assistant, place a rear corner of the PDU at an inside
edge of the mounting clips, pivot the PDU toward the
alternate inside edge and snap into place.
3
Attach the input plug of the PDU to a grounded
outlet. Insert the plug directly into a grounded outlet
that does not share a circuit with a heavy electrical
load (such as an air conditioner or refrigerator).
4
Attach equipment to the PDU. Do not exceed the
load rating of the PDU. The total electrical current used
by the PDU will be displayed on the digital meter in
amperes (models PDUMV15 and PDUMV20 only).
5
Optional Installation (Models PDUMV20 and
PDUV20). The PDU includes an adapter that converts
the L5-20P input plug to a 5-20P input plug. The
adapter is optional; the PDU will work properly without
connecting the adapter.
2
1B
1A
3
4
5
PDUMV15 and PDUV15
PDUMV20 and PDUV20
PDUMV20 and PDUV20
1C
Installation
20-09-044-93364D.indb 3


Product specificaties

Merk: Tripp Lite
Categorie: Stekkerdoos
Model: PDUV15-48
Kleur van het product: Zwart
Gewicht: 1700 g
Breedte: 38.1 mm
Diepte: 41.7 mm
Hoogte: 1231.1 mm
Snoerlengte: 4.57 m
Gewicht verpakking: 2010 g
Breedte verpakking: 87.1 mm
Diepte verpakking: 61 mm
Hoogte verpakking: 1315 mm
Gebruikershandleiding: Ja
Materiaal behuizing: Metaal
LED-indicatoren: Ja
Land van herkomst: China
Certificering: UL60950-1 (USA) and CAN/CSA C22.2 No. 60950-1-03 (Canada)
Duurzaamheidscertificaten: RoHS
Temperatuur bij opslag: -15 - 50 °C
Hoogte, in bedrijf: 0 - 3000 m
Montage: Verticaal
Stekker: NEMA L5-15P
(Buitenste) hoofdverpakking hoogte: 214.9 mm
(Buitenste) hoofdverpakking breedte: 195.1 mm
(Buitenste) hoofdverpakking brutogewicht: 12830 g
(Buitenste) hoofdverpakking lengte: 1335 mm
Hoeveelheid per (buitenste) hoofdverpakking: 6 stuk(s)
Rackcapaciteit: 0U
AC-ingangsfrequentie: 50/60 Hz
GTIN (EAN/UPC)-nummer (buitenste) hoofdverpakking: 10037332255812
Aantal AC uitgangen: 16 AC-uitgang(en)
Nominale input voltage: 100-127 V
Stopcontacttypes: NEMA 5–15R
Stroom (max.): 15 A
PDU types: Basis
Rekbevestigingspakket: Ja
Netspanning, in bedrijf: 100-127 V