Tripp Lite AVS5D Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Tripp Lite AVS5D (8 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 17 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/8
1
Automatic Voltage
Switch
Model: AVS5D
Owner’s Manual
1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/support
Copyright © 2014 Tripp Lite. All rights reserved.
Introduction
The AVS5D is a 5 amp rated automatic voltage switch that protects appliances
from high voltages, low voltages (including brownouts), power surges, spikes and
lighting. It does this by switching off connected equipment if the power flowing to it
goes outside preset limits, and will reconnect automatically when power returns to
normal (except in the case of an overload condition). There will be a delay before
the reconnection to ensure power stability.
14-01-269-933302.indd 1 2/6/2014 2:33:58 PM
2
Product Overview
1 BS 1363 Plug Connects to wall outlet.
2 BS 1363 Outlet Connects to appliance plug.
3 F1 & F2 Program Buttons Using the two buttons, you can set the output
over/under voltage, overload protection value, browse settable parameters and
change digital display mode. During normal operation, you can press F2 to
display the load. After 3 seconds, the switch returns to the voltage display.
5 Voltage LED Illuminates when the digital display shows voltage.
6 Load LED Illuminates when the digital display shows the load in watts.
4
1
2
43
6
5
7
14-01-269-933302.indd 2 2/6/2014 2:33:58 PM
3
Product Overview
7 Digital Display Shows voltage, wattage, status and settings.
A) U-H Output Overvoltage Protection Status
When output voltage exceeds the preset limit and doesn’t return to within
the preset limits after 1 second, your equipment will be disconnected by
the switch. U-H will flash on the display every .5 seconds as long as the
overvoltage condition exists.
B) U-L Output Undervoltage Protection Status
When output voltage goes lower than the preset limit and doesn’t return to
within the preset limits after 1 second, your equipment will be disconnected
by the switch. U-L will flash on the display every .5 seconds as long as the
undervoltage condition exists.
C) P-H Overload Protection Status
When the load exceeds the preset range (nominally 110-120%) and lasts
longer than 6 seconds (within this 6 seconds no action will be taken by the
AVS5D), the switch will disconnect from power. P-H will flash on the display
every .5 seconds as long as the overload condition exists.
When the load exceeds the preset range (nominally 150%) and lasts longer
than 1 second, the switch will disconnect from power. P-H will flash on the
display every .5 seconds as long as the overload condition exists.
Overload Faults - You must power cycle the unit to restore the currentow.
The unit does not reset automatically from this type of fault.
D) Start Up Delay
When first powered up, the unit will count down a set number of seconds
(default is 6) before monitoring voltage.
E) Parameter Setting Codes
E-0 Delay setting
E-1 Undervoltage protection value setting
E-2 Overvoltage protection value setting
E-3 Overload protection value setting
E-4 Displays output voltage or loading power value after startup
(U= voltage, P= watts)
E-5 Restores default settings
Note: The code and value flash alternately every second while changing settings.
14-01-269-933302.indd 3 2/6/2014 2:33:58 PM


Product specificaties

Merk: Tripp Lite
Categorie: Niet gecategoriseerd
Model: AVS5D
Kleur van het product: Wit
Breedte: 64 mm
Diepte: 47.8 mm
Hoogte: 132.1 mm
Gewicht verpakking: 180 g
Breedte verpakking: 85.9 mm
Diepte verpakking: 66 mm
Hoogte verpakking: 134.9 mm
Certificering: CE
Materiaal: Kunststof
Duurzaamheidscertificaten: RoHS
Stekker: Type G (BS 1363)
(Buitenste) hoofdverpakking hoogte: 205 mm
(Buitenste) hoofdverpakking breedte: 330.2 mm
(Buitenste) hoofdverpakking brutogewicht: 6530 g
(Buitenste) hoofdverpakking lengte: 415 mm
Hoeveelheid per (buitenste) hoofdverpakking: 36 stuk(s)
Aantal producten inbegrepen: 1 stuk(s)
Surge energy rating: 190 J
Aantal AC uitgangen: 1 AC-uitgang(en)
Nominale input voltage: 220-230 V
Stopcontacttypes: BS 1363

Heb je hulp nodig?

Als je hulp nodig hebt met Tripp Lite AVS5D stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Tripp Lite

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd