Theben EM 4 top2 Handleiding


Pagina's 1 Niet gecategoriseerd

Bekijk de handleiding van Theben EM 4 top2 gratis online of download de PDF. Deze handleiding is 266 keer bekeken. Vraag over dit model? Stel een vraag

EM 4 top2
4-channel extension module
for TR top2 RC
6490104
309430 02
Designated use
The EM top2 module upgrades the 365-day time switch TR 641
top2 RC, TR642 top2 and TR 644 top2 to 4 channels (C5-C8).
interface. Corresponds to type 1 B in accordance with IEC/EN
60730-1.
Install EM 4 top2
• The EM top2 module is designed for installation on DIN top
hat rails (in accordance with EN 60715).
• Strong interference fields can have an effect on the clock.
Do not install module near inductive consumers.
Lay separate cable for power supply.
Shield inductive consumer.
red LED set flashes: a 365-day time
switch TR top2 sends requests "As-
sign module EM 4" ( teach-in)
yellow LEDs light up: Channels C5-C8
are on
4 blue manual buttons
Description
EM 4 top2 "teach-in"
In the 365-day time switch in the menu under OPTIONS
select EXTENSION MODULE EM4ASSIGN MODULE
EM4.
The LED set flashes on EM 4 top2.
Assign EM 4 top2 with the C5 button. The LED Set goes out.
EM 4 top2 "teach-out"
Press all 4 EM 4 top2 manual button longer than 2 sec.
The LED flashes quickly, the EM 4 module is taught-out
(no time switch is assigned); EM 4 top2 can now be
assigned by a new time switch.365-day
Manual control
Quickly press channel keys C5-C8.
Permanent switching
Press channel keys C5-C8 longer. (> 2 sec).
Connect EM 4 top2
Safety advice
Danger of death through electric shock or
fire!
Installation should only be carried out by a
qualified electrician!
WARNING
Technical data
• Operating voltage: 110 –240 V~, +10 %/-15 %
• Frequency: 50-60 Hz
• Power consumption: typically 7,5 VA
• Standby: typ. 2.8 W
• DATA bus: Bus voltage: 18 V DC
• Switching capacity: 16 (10) A (C6+C8), 10 (10) A
(C5+C7)
• Permissible ambient
temperature: typical –30 °C... +45 °C,
temporary +55 °C
• Protection class: II in accordance with EN 60730-1
for designated installation
• Protection rating: IP 20 in accordance with EN 60529
• Pollution degree: 2
• Rated impulse withstand voltage: 4 kV
• Power supply on the DATA bus: 100 mA
(maximum current on the DATA bus:
500 mA)
Service address
Theben AG
Hohenbergstr. 32
72401 Haigerloch
GERMANY
Telephone +49 7474 692 0
Fax +49 7474 692-150
Hotline
Telephone +49 7474 692-369
Fax +49 7474 692-207
Addresses, telephone numbers etc.
www.theben.de
C6C8
C5
123789
456101112
N
L
L
C7
LN
Ext5
max. 100 m
max. 100 m
max. 100 m
max. 100 m
Ext6Ext7Ext8Data
TR 64.
top2
RC
EM 4 top2
DATA
C5
C6
C7
C8
Ext1
LN
1
C5
2
3
µ
4
C6
5
6
µ
Ext2Ext3Ext4
10
C8
11
12
µ
7
C7
8
9
µ
2
2,5mm
2
0,5mm-
110-240V~
50-60Hz
R8a - 30T
C6/C8
16(10)A 250V~
C5/C7
10(10)A 250V~
8mm
L
N
Set
-
+
The supply of L and N is the same as with the TR 64x top2 (RC)
basic device.

Beoordeel deze handleiding


Product specificaties

Merk: Theben
Categorie: Niet gecategoriseerd
Model: EM 4 top2

Heb je hulp nodig?

Als je hulp nodig hebt met Theben EM 4 top2 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden