Sven SV12120 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Sven SV12120 (2 pagina's) in de categorie Niet gecategoriseerd. Deze handleiding was nuttig voor 141 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/2
12 V
12 A h at 20Hr-rate to 1.75V/cell
3.75 Kg
6
15 m (Fully Charged) at 25 °CΩ
Average 3% of capacity declined per
month at 25 °С
Discharge: -20 °C ~ 50 °C
Charge: -15 °C ~ 40 °C
Storage: -20 °C ~ 40 °C
180 A (5 sec.)
40 °C 102%
25 °C 100%
0 °C 85%
-15 °C 65%
ABS plastic
Nominal Voltage
Nominal Capacity
Approx. Weight
Number of cells in battery
Internal Resistance
Self-Discharge
Operating Temp. Range
Max. Discharge Current
Capacity
A ected by Temp.
Container Material
SPECIFICATION
APPLICATION
All Purpose
UPS
Signal Light
Alarm and Security System
DC Power Supply
Auto Control System
APPLICABLE STANDARDS
IEC61056-1/2
JIS C8702-2003
GB/T19639.1-2005
CI C
ISO14001
TB 0907 59 35
ISO9001
C
C
C
C
CQ
Q
Q
Q
Q
C
C
C
C
C
MH 47104
CHARGE PROCEDURE DISCHARGE CURRENT VS. DISCHARGE VOLTAGE
Application Final Discharge
Voltage (V/cell)
Discharge
Current (A)
Constant Voltage Charge (V/cell)
Temperature Set Point Allowable Range
Max. Charge
Current
Cycle Use
Standby Use
25 °C
25 °C
2.425
0.3C
2.275
2.40~2.45
2.25~2.30
Note: Temp. Compensation Coef cient of Charge Voltage,
Cycle use: -4mV/°C/cell, Standby Use: -3 mV/°C/cell
1.75 1.70 1.60
0.2C>(A) 0.2C<(A)<1C (A)>1C
you want - we can
Rechargeable VRLA Battery
SV12120
FEATURES
AGM maintenance-free lead-acid battery
High-e ciency lead-calcium plates
Construction of ber-glass separators
stabilizes temperature of electrolyte
High-quality insulation of plates
Safe system of internal pressure regulating
valves
Reduced self-discharge current
Sealed construction
Long cycle life both in oat and cycle charge
modes
Quality of products is guaranteed by the
control of the manufacturing process in
accordance with the standards
F.V.
(V/cell)
1.60
1.70
1.75
1.80
1.85
Charge current
Temperature: 25°C
100% (0.05C×20H)
50% (0.05C×10H)
Charge
Charge Voltage: 2.275V/cell
Charge Сurent: 0.1CA
Discharge
Charge quantity
Battery Voltage
0.02
0.05
1.40
1.60
1.80
2.00
2.20
2.40
2.60
0.08
0.11
0.14
0.17
0.20
120
140
13.0
12.0
11.0
10.0
9.00
Terminal Voltage (V)
0.16C 0.093C 0.05C
0.62C
0.35C
1C3C
Discharge Time
min Hr
201051 2301231.2 6
.
0.6 24
20 24
Charge Time (Hr)
0 4 8 12 16
0
00
60
40
20
80
100
1
2
3
Time
Model
12001000800600400
20
40
60
80
100
Length
151 ± 1.5
Width
98 ± 1.5
Height
94 ± 1.5
Total height
98 ± 2.0
Unit: mm
Terminal Type
Terminal F2
3.6
8.1
6.2
94±1.5
98±1.5
98±2.0
151±1.5
0.72
OUTER DIMENSION
40
60
80
100
2018161412108
6
42
0
0
Capacity Retention Ratio (%)
No supplementary charge required
(Carry out supplementary charge
before use if 100%capacityis required)
Supplementary charge required
before use.
This supplementary charge will help
to recover the capacity and should
be made as early as possible.
Supplementary charge may often
fail to recover the capacity.
The battery should never be left
standing till this state is reached.
Supplementary charge and storage guidelines
25°C30°C40°C
5°C
200
50% DOD 30% DOD
0
Capacity (%)
120
CC(A)
CP(W)
5 Min 10 Min 15 Min 30 Min 1 Hr 2 Hr 3 Hr 4 Hr 5 Hr 8 Hr 10 Hr 20 Hr
46.8 30.68 22.75 14.95 7.8 4.55 3.35 2.69 2.28 1.51 1.23 0.67
552 346.7 262.2 158.7 89.9 52.7 38.7 31.1 26.4 17.4 14.2 7.8
42.9 29.36 20.91 14.19 7.32 4.37 3.25 2.6 2.24 1.48 1.21 0.66
519.5 328.3 246.5 157.6 84.5 50.5 37.6 30.1 25.9 17.1 14 7.6
39.05 27.43 19.50 13.76 7.09 4.28 3.20 2.47 2.23 1.46 1.2 0.65
501.6 318.5 235.6 156 82 49.6 37 28.6 25.7 17 13.9 7.5
37.53 26.22 18.20 13.38 6.85 4.17 3.14 2.43 2.11 1.42 1.16 0.63
439.8 308.8 227.0 155.5 79.6 48.5 36.6 28.2 24.6 16.3 13.5 7.4
34.71 24.70 16.90 13 6.61 4.06 2.98 2.38 2.02 1.39 1.14 0.62
425.2 298.5 216.1 154.4 78.5 48.2 35.5 28.2 24.1 15 .7 13.3 7.3
Note: The above data are average values, and can be obtained with 3 charge/discharge cycles.
CC(A)
CP(W)
CC(A)
CP(W)
CC(A)
CP(W)
CC(A)
CP(W)
Constant Current (CC,Unit: A) & Constant Power (CP, Unit: W) Discharge Table at 25 °C
Ambient Temperature: 25 °C
100% DOD
Battery Voltage (V/Per Cell)
Charge Current (CA)
Charge Quantity (%)
Discharge Characteristics at 25 °C Charge characteristics (Standby use)
Storage Period (Month)
Capacity Retention Characteristics
Number of Cycles (Times)
Cycle Service Life


Product specificaties

Merk: Sven
Categorie: Niet gecategoriseerd
Model: SV12120

Heb je hulp nodig?

Als je hulp nodig hebt met Sven SV12120 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Sven

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd