Sievert ProVenturix S90 Handleiding
Pagina's 40 Niet gecategoriseerd
Bekijk de handleiding van Sievert ProVenturix S90 gratis online of download de PDF. Deze handleiding is 0 keer bekeken. Vraag over dit model? Stel een vraag

1
PRO VENTURIX
Pro Venturix – Burners
Pro Venturix – Handle
Pro Venturix – Regulator
EN
Operating Instructions 1
Safety Instructions / Declaration 5-7
SE
Bruksanvisning 1
Säkerhetsanvisningar / Deklaration 9-11
NO
Bruksanvisning 1
Sikkerhetsanvisninger / Deklarasjon 13-15
DK
Brugervejledning 1
Sikkerhedsinstruktioner / 17-19
Overensstemmelseserklæring
FI
Käyttöohje 1
Turvaohjeet / Vaatimustenmukaisuus 21-23
DE
Bedienungsanleitung 1
Sicherheitshinweise / Erklärung 25-27
NL
Gebruiksaanwijzing 1
Veiligheidsvoorschriften / Verklaring 29-31
FR
Mode d’emploi 1
Instructions de sécurite / Déclaration 33-35
54705_1
Designed in Sweden
Manufactured in Estonia
54705_Pro Venturix Instruction Manual.indd 154705_Pro Venturix Instruction Manual.indd 12024-06-18 12:08:322024-06-18 12:08:32

2
ENSENODKFIDENLFR
3
Getting started / Komma igång / Starter / Kom godt i gang / Päästä alkuun /
Inbetriebnahme / Beginnen / Commencer
17 mm
19 mm
19 mm
19 mm
19 mm
C
M
Y
CM
MY
CY
CMY
K
Neck tube on handle2.AI 1 2022-08-26 16:08:00
C
M
Y
CM
MY
CY
CMY
K
Venturix flatburner manual page 11.AI 1 2022-08-26 16:11:17
C
M
Y
CM
MY
CY
CMY
K
Venturix classic mounting.AI 1 2022-08-30 09:06:24
C
M
Y
CM
MY
CY
CMY
K
Venturix flat bild 1.AI 1 2022-09-02 15:19:56
1
4
7
10
13
2
5
8
11
3
6
9
12
54705_Pro Venturix Instruction Manual.indd 254705_Pro Venturix Instruction Manual.indd 22024-06-18 12:08:332024-06-18 12:08:33

3
EN
Technical Data
Pro Venturix C60 Burner496000
Burner Diameter, mmØ 60 mm
Number of Core Flames4
Gas Consumption, g/h at 3,7 Bar980 g/h
Effect, kW12,6 kW
Noise, dB82 dB
Pro Venturix D60 Burner356002
Burner Diameter, mmØ 60 mm
Number of Core Flames4
Gas Consumption, g/h at 3,7 Bar980 g/h
Effect, kW12,6 kW
Noise, dB82
Fixed Titanium Neck TubeYes
Pro Venturix S130 Burner696000
Burner Width, mm130 mm
Burner Height, mm22 mm
Number of Core Flames6
Gas Consumption, g/h at 3,7 Bar1100 g/h
Effect, kW14,2 kW
Noise, dB80 dB
Pro Venturix S90 Burner696090
Burner Width, mm90 mm
Burner Height, mm22 mm
Number of Core Flames4
Gas Consumption, g/h at 3,7 Bar650 g/h
Effect, kW8,3 kW
Noise, dB80 dB
54705_Pro Venturix Instruction Manual.indd 354705_Pro Venturix Instruction Manual.indd 32024-06-18 12:08:332024-06-18 12:08:33