Bekijk gratis de handleiding van Scotsman UF424 (12 pagina’s), behorend tot de categorie Niet gecategoriseerd. Deze gids werd als nuttig beoordeeld door 39 mensen en kreeg gemiddeld 4.4 sterren uit 20 reviews. Heb je een vraag over Scotsman UF424 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/12

Installation and User Manual for
Model UF424 and UN324

UF424 / UN324 Installation and User Manual
August 2017
2
To the owner or user: the service manual is intended
to provide you and the maintenance or service
technician with the information needed to install,
startup, clean, maintain and repair this product.
Observe any caution or warning notices. They are
important and provide notice of potential hazards.
Keep this manual for future reference.
If additional technical information is needed, go to
Scotsman’s website, www.scotsman-ice.com to
download a service manual.
Note: This is a commercial product. If service is
needed on a unit in a residence, warranty may be
limited. Use a commercial service company. Locate
one from the Scotsman website: www.Scotsman-ice.
com
Table of Contents
Specications ....................................................................................................................3
Cabinet Drawing ................................................................................................................4
Placement..........................................................................................................................5
Installation: Water and Drain ............................................................................................6
Initial Start up.....................................................................................................................7
Maintenance and Cleaning ................................................................................................8
Basic Troubleshooting .................................................................................................... 10

UF424 / UN324 Installation and User Manual
October 2017
3
Specications
This ice maker is designed to be installed in-
doors, in a controlled environment. Although
it can operate in a wide range of air and water
temperatures, it will provide the best performance
if not subject to extremes.
Air Temperature Limitations
• Maximum: 100o
F or 38o C
• Minimum: 50o F or 10o C
Water Temperature Limitations
• Maximum: 100o F or 38o C
• Minimum: 40o F or 4.4o
C
Water Pressure, Potable
• Maximum: 80 PSI or 5.5 BAR
• Minimum: 20 PSI or 1.3 BAR
Water Pressure, Condenser inlet
• Maximum: 145 PSI or 10 BAR
• Minimum: 20 PSI or 1.3 BAR; can be as low
as 5 PSI or 0.3 BAR if clean and supplied
with 45o F water.
Condenser GPM
• 70oF or 21oC water: 0.25 GPM or 0.95 LPM
• 50o F or 10oC water: 0.15 GPM or 0.57 LPM
Voltage
115 volt models
• Maximum 126 VAC
• Minimum 104 VAC
230 volt models
• Maximum 207 VAC
• Minimum 253 VAC
Water Conductivity:
Minimum:10 micro Siemens/CM
RO water may be supplied to the potable water
system, but if it has less than the above conduc-
tivity, the water level sensor will not detect water
and the unit will not make ice.
Deionized water is not recommended due to
it’s potential corrosive nature and any damage
caused by DI water will not be covered by war-
ranty.
Operating the machine outside of any of the
above limitations is considered abuse and any
resulting damage is not covered by warranty and
could cause a complete loss of warranty cover-
age.
Warranty Information
The warranty statement for this product is pro-
vided separately from this manual. Refer to it for
applicable coverage. In general warranty covers
defects in material or workmanship. It does not
cover maintenance, corrections to installations,
or situations when the machine is operated in
circumstances that exceed the limitations printed
above.
Product Information:
The UF424 produces aked ice and the UN324
produces nugget ice. The ice is stored in an
insulated bin with ice level automatically main-
tained by the control system.
• A back ow preventer may be required by
local plumbing codes.
• Has a 5.5 ft. power cord with NEMA 5-15P
plug.
• Air cooled models ows in the right front and
out the left front and include a cleanable air
lter.
• Legs are provided, thread size is 5/8-11.
• Machine may be installed without legs.
• For available options and kits, see sales
literature.
Model
Electrical
(Volts/Hz/Phase)
Condenser
Maximum Fuse Size
or Breaker
(Amps)
UF424A-1A / UN324A-1A 115/60/1 Air 15A
UF424W-1A / UN324W-1A 115/60/1 15AWater
Product specificaties
Merk: | Scotsman |
Categorie: | Niet gecategoriseerd |
Model: | UF424 |
Heb je hulp nodig?
Als je hulp nodig hebt met Scotsman UF424 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Niet gecategoriseerd Scotsman
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
1 April 2025
Handleiding Niet gecategoriseerd
- Royale
- Sun Pumps
- Ansco
- Princeton Tec
- Enbrighten
- Lowepro
- G3
- Caliber
- Cardiostrong
- AquaMAX
- Thames & Kosmos
- Acard
- Hameg
- Ulanzi
- Lanzar
Nieuwste handleidingen voor Niet gecategoriseerd
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025
17 Juni 2025