Bekijk gratis de handleiding van Schwaiger ZHD01 (2 pagina’s), behorend tot de categorie Thermostaat. Deze gids werd als nuttig beoordeeld door 47 mensen en kreeg gemiddeld 4.5 sterren uit 4 reviews. Heb je een vraag over Schwaiger ZHD01 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/2
USER MANUAL ZHD01
TEMPERATURE SENSOR
ZHD01
MANUFACTURER INFORMATION
Dear Customer,
should you require technical advice and your
retailer could not help please contact our
technical support.
Schwaiger GmbH
Würzburger Straße 17 90579 Langenzenn
Hotline: +49 (0) 9101 702-199
www.schwaiger.de info@schwaiger.de
BDA_ZHD01
Business hours:
Monday to Thursday: 08:00 - 17:00
Friday: 08:00 - 14:30
HOME AUTOMATION
Congratulations and thank you for purchasing the Schwaiger ZHD01
product. Below you will find useful operating guidelines.
Display information
Display LEDExplanation
Room temperature displayed
Rapid green flashing
Red flashing
Flashes
Runs insertions or deletions
Red flashing every
150 seconds
Red flashing every
30 seconds
Insertions or deletions failed
Z-Wave information
General device classMulti-level sensor
Specific device classRouting multilevel sensor
Device typeRouting slave
SDK 4.55
NWI Yes
Explorer framesYes
Manufacturer ID0x0002
Product type ID0x0003
Product ID0x8010
Introduction
Schwaiger ZHD01 is a battery-operated temperature sensor. If it is integrated into the wireless
Z-Wave network, the control buttons can be used to control the heating system.
Disposal information
This device contains no batteries. It is an electrical device. It can be disposed of free of charge at
specified disposal sites.
EC Declaration of Conformity
„Hereby Schwaiger GmbH declares that the ZHD01 product is in compliance with the essential requi-
rements and other relevant provisions of Directive 1999/5/EC. “ The Declaration of Conformity can be
found at the following address: http://www.schwaiger.de/downloads
Installation
LED button
INCREASE temperature
Display
(with backlight)
LOWER temperature
1. Remove the back panel by
sliding it downwards.
3. Fasten the back panel to the wall.
2. Replace the batteries.
4. Gently push the Z-Wave RS on the back panel.
Z-Wave command classes
Command ClassVersionDescription
BASICV1• Basic SET: Not supported
• Basic GET: Multi-level sensor get
• Basic REPORT: Multi-level sensor report
(1 °C accuracy)
MANUFACTURER_
SPECIFIC
V2ID from Danfoss and Z-Wave RS
VERSIONV2Version of command classes, of the Z-Wave Library
and of Z-Wave RS
BATTERYV1Battery status
MULTI_CMDV1Conserve battery power by transmitting multiple com-
mands in a single package
WAKE_UPV2Switch-on intervals of 5 min to 24 h (default: 60
minutes)
PROTECTIONV20 = No protection
2 = User interface locked
CONFIGURATIONV2Specific Z-Wave RS configuration
SENSOR_MULTILEVELV6Specifies the value from the room temperature sensor
again
CENTRAL_SCENEV1By pressing the LED button the transmission of
CENTRAL_SCENE_ NOTIFICATION is triggered.
THERMOSTAT_
SETPOINT
V3When selecting a temperature setpoint on the display
controller, the setpoint is reported.
SCHEDULEV1When selecting a temperature and a number of hours
on the display controller reported the program change
values.
INDICATORV1Control of the LED display.
Paste in Z-Wave
Make sure that Z-Wave RS is in the factory defaults setting.
Activate „Inclusion/Paste“ on the Z-Wave controller.
Press the LED button on Z-Wave RS.
Check the process status on the controller and Z-Wave RS.

Beoordeel deze handleiding

4.5/5 (4 Beoordelingen)

Product specificaties

Merk: Schwaiger
Categorie: Thermostaat
Model: ZHD01
Ingebouwd display: Ja
Breedte: 81 mm
Diepte: 21 mm
Hoogte: 66 mm
Beeldscherm: LCD
Connectiviteitstechnologie: Draadloos
Ondersteund aantal accu's/batterijen: 2
Materiaal: Kunststof
Bedoeld voor: Binnen
Temperatuur bij opslag: - °C
Type batterij: AA
Meetbereik vochtigheid: - procent

Heb je hulp nodig?

Als je hulp nodig hebt met Schwaiger ZHD01 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden