Saxon SA6033 Handleiding
Saxon
Weerstation
SA6033
Bekijk gratis de handleiding van Saxon SA6033 (10 pagina’s), behorend tot de categorie Weerstation. Deze gids werd als nuttig beoordeeld door 82 mensen en kreeg gemiddeld 4.4 sterren uit 41.5 reviews. Heb je een vraag over Saxon SA6033 of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/10

PROFESSIONNAL WEATHER STATION
- Instruction Manual -
1/ FUNCTION DESCRIPTION
5 kinds of weather forecast, BAR display in dynamic curve, pressure measurement, history record and trend display of pressure in the past 12 hours
Max/min value of indoor temperature and humidity
Five channels in total. Three channels for outdoor temperature and humidity, one for wind speed and direction, and the other for rainfall.
Max/ min value and trend of outdoor wireless temperature and humidity.
Real-time outdoor wireless wind speed and direction, the average of wind speed, wind trend and max and min value of the wind information.
Outdoor heat index, dew point, chill coefficient.
Display the rainfall of current day; the current rainfall rate; Record of the past 1 hour, 24hours, 1 week and 1 month.
Perpetual calendar with moon phase, RCC DCF
Alarm, backlight, snooze
2/ MAIN FUNCTION
12 functional keys: -/RCC、+/℃/℉、MODE、CHANNEL、MAX/MIN、SNOOZE/LIGHT、ALERT、HISTORY、RAINFALL、ALARM ON/OFF、HI/DP/CHILL、WIND.
Automatically clock receiving (DCF)
Daylight saving time.
Time and perpetual calendar displaying.
Two time format to be selected 12/24 hr.
Single alarm, five minutes snooze function.
Two temperature display format options (℃ / ℉).
Indoor temperature and humidity displaying.
Range of indoor temperature testing: -10℃~ 60℃ (14 ℉ ~ 140℉) testing cycle: 30 seconds
Range of indoor humidity testing: 20% ~ 95%.
Max and min values of Indoor temperature and humidity.
Three different wireless channels work together for three sets receiving of outdoor temperature and humidity. Range of temperature testing: -40 ℉ ~ 158 ℉; Testing cycle: about 1
minute.
The max and min of outdoor temperature and humidity.
The up and low limit of indoor and outdoor temperature alarm.
Indoor/ outdoor temperature trend.
Range of outdoor wind speed and direction testing: 00KM/Hr ~ 150KM/Hr, 16 wind directions index.
The average wind speed, max and min record and / trend of wind speed.
ENGLISH

The average and real-time wind speed display.
RF outdoor rainfall detection.
Rainfall display: total rainfall of the day, current rainfall rate, rainfall of the past 1 hour &24 hours, 1 week and Last month
Unit to select: mm (/ h) or inch (/ h).
Calculate of outdoor Dew point, Heart index and Wind chill.
5 kinds of weather forecast: sunny, semi-sunny, cloudy, rainy and stormy.
Atmospheric pressure unit selection: mb / hpa or inHg.
Record of atmospheric pressure changes in the past 12-hour.
BAR display of the atmospheric pressure in the past 12-hour.
Moon phase calculate.
Receiver can display low power index of 4 parts: Receiver, temperature sensor , wind speed sensor , rainfall sensor.
LED backlight.
3/ POWER AND RESET
After put on the battery, LCD will display three seconds with a sound of BI at the sametime, start detecting temperature humidity and pressure inside the sensor, and then
automatically enter the RF and RCC receiving. RCC receiving for 7 minutes, exit after received or press "-/RCC" key to exit.
Perpetual calendar defaults to 1 January, 2009 0: 00.
Alarm default (AM) 7:00.
The time format default for 24 hr.
Default temperature unit (DCF): ℃.
Default weather symbol: cloudy.
Default pressure unit is hpa mBar.
Default rainfall unit is mm (mm/hr).
4/ OPERATION
4.1/ KEY FUNCTIONS

OPERATION
FUNCTION
MODE
ALA
RM
+/℃/℉
- / RCC
HI/DP/CHILL
SNOOZE/LIGHT
CHANNEL
RAINFALL
ALERT
MAX/MIN
HISTORY
WIND
Normal
mode
Press
once
Switch between alarm
mode /time mode
On/ off alarm under
not setting mode
Switch
between ℃/℉
Switch time
zone, stop
receiving RCC
Switch among Heat
Index
/Dew Point
/Wind Chill under
not setting mode
Backlight for 5second,press
into snooze when alarming
Switch between
CH1,2,3,
Switch display
of rainfall
On/off
temperature
alarm
To check max
And min value
of temperature/
humidity and
wind speed
To check pressure
of the pass 12
hours
――
Hold
Enter time setting
mode (when in alarm
mode enter alarm
setting)
———
Force into RCC
receive
Clear all RF
channels
Enter rainfall
unit setting
Enter setting of
temperature
alarm
Clear all records of
temperature and
humidity
Enter relative
pressure setting
Enter
relative
wind setting
Time
setting
Press
once
Confirm setting
Ahead by one
step
Back by one
step
———
———
———
———
Hold
———
Ahead by 8
steps /second
Back by 8 steps
/second
———
———
———
———
Alarm
setting
Press
once
Confirm setting
Ahead by one
step
Back by one
step
———
———
———
———
Hold
———
Ahead by 8
steps
/second
Back by 8 steps
/second
———
———
———
———
Temperature
alarm
setting
Press
once
———
Ahead by one
step
Back by one
step
Select the
channel
———
Confirm setting
———
———
Hold
———
Ahead by 8
steps /second
Back by 8 steps
/second
———
———
———
———
———
Pressure
setting
Press
once
———
Ahead by one
step
Back by one
step
———
———
Confirm setting
Hold
———
Ahead by 8
steps /second
Back by 8 steps
/second
———
———
———
———
———
Rainfall
setting
Press
once
———
Change rainfall unit
Confirm setting
———
———
———
———
wind
speed
Press
once
———
Ahead by one
step
Back by one
step
———
———
Confirm
setting
Hold
———
Ahead by 8
steps /second
Back by 8 steps
/second
———
———
———
———
———
Product specificaties
Merk: | Saxon |
Categorie: | Weerstation |
Model: | SA6033 |
Heb je hulp nodig?
Als je hulp nodig hebt met Saxon SA6033 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Weerstation Saxon
26 September 2023
26 September 2023
30 Oktober 2022
Handleiding Weerstation
- JDC
- Setti+
- Greisinger
- Braun
- Greenure
- Elgato
- OBH Nordica
- TFA Dostmann
- Gewiss
- EVE
- Solar
- Krontaler
- Denver
- Honeywell
- Unitec
Nieuwste handleidingen voor Weerstation
16 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025
11 Juni 2025