Bekijk gratis de handleiding van Sauermann MP 120L (7 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 4.9 sterren uit 3.5 reviews. Heb je een vraag over Sauermann MP 120L of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/7

Quick Start Guide
CLASS 110 PORTABLES
AQ 110, CO 110, CT 110, HD 110, LV 110-111-117, LV 130,
MP 110-111-115-112, MP 120, MP 130, VT 110-115
www.sauermanngroup.com
EN FR ES DE ZH

English
Quick Start Guide
Class 110 portables
3. Take a measurement
Switch on the instrument by pressing briey on “On/Off/Esc”.
The instrument displays its name then the measurement.
VT 110: before using the instrument with the hotwire probe, please lower the protection tube (1) of the
sensing element.
VT 110: always use the hotwire probe with the red point (VT 110) or white point (VT 115) in front of ow.
CO 110 and AQ 110: the instrument displays its name then a 5 s (CO 110) or 10 s (AQ 110) countdown. This
count corresponds to the preheating time of the sensor. At the end of the countdown, the measured value of CO
and CO
2
is displayed.
MP 110, MP 120 and MP 130: the instrument displays its name then an autozero is performed. At the end of
the autozero, the measured value displays.
2. Keys
9. Batteries replacement
The instrument is OFF.
Remove the front part at the back of the instrument.
Replace used batteries by new batteries AAA LR03 1.5 V.
Replace the front.
These portable instruments are used to measure the following parameters: temperature, relative humidity, pressure,
airow and air velocity, CO and CO
2
.
1. Operating temperature, protection of the instruments and information about storage
Conditions of use (°C/%RH/m): from 0 to +50 °C / 32 to +122 °F (AQ 110 / CO 110 / CT 110 / LV 110-111-117 / LV 130 /
MP 110-111-115-112 / MP 120 / MP 130 / VT 110-115); from -10 to 50 °C / 14 to +122 °F (HD 110).
In non-condensing conditions. From 0 to 2000 m / 0 to 2188 yd.
Protection: IP54
Storage temperature: from -20 to +80 °C / -4 to +176 °F.
If the instrument is stored outside the operating temperature (for example in a van, a warehouse...), please wait for 10
minutes in its operating temperature before start using it.
To ensure safety, replace batteries with the same type.
Not doing so might lead to explosion. Dispose of used batteries according to instructions.
8. Activate or deactivate the keys beep
The device is on and displays the measurements.
Press "Select" until "BEEP" blinks on the screen and follow the instructions above:
7. Set the auto-off
The device is on and displays the measurements.
Press “Select“ until “AUTO OFF“ blinks on the screen and follow the instructions above:
6. Display minimum and maximum values
When measurements are hold:
Press “On/Off/Esc”: maximum value measured since the last questioning is displayed on the top of the screen and
minimum value measured since the last questioning is displayed on the bottom of the screen.
KEY FUNCTION
ON-OFF/Esc. Turn the instrument on/off and allow to back to previous selection.
OK key. Conrm selection
Select key. Navigate throught the menu
HOLD/min/max key. Hold value, and display minimum and maximum values
Backlight key. Activate/Deactivate the backlight
5. Hold the measurement
During measurement, press briey on “Hold/min/max” to hold measurement: “Hold” appears on the screen and
measurements are xed.
Press again briey “On/Off/Hold” to exit the Hold function.
During measurement:
Remove pressure tubes and press “OK”.
The instrument makes an autozero then returns to the measurement display.
4. Carry out a manual autozero (MP 110, MP 120, MP 130)
Sensing
element
(temperature)
Sensing
element
(velocity)
Airow direction
Protection tube
of the sensing
element (1)
Redpoint: landmark
Bottom of the
hotwire probe
Sensing
element
(temperature)
Sensing
element
(velocity)
Airow direction
Protection tube
of the sensing
element (1)
White point:
landmark
Bottom of the
hotwire probe
VT 110 VT 115
Switch on the instrument by pressing briey on “On/Off/Esc”.
During start-up, carry out a long press simultaneously on ”On/Off/Esc” and “Select“.
Select the required language (English, French) with “Select“ key. Validate pressing “OK”.
3. Select the language of the device
Product specificaties
Merk: | Sauermann |
Categorie: | Meetapparatuur |
Model: | MP 120L |
Heb je hulp nodig?
Als je hulp nodig hebt met Sauermann MP 120L stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur Sauermann
2 September 2025
2 September 2025
2 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
1 September 2025
Handleiding Meetapparatuur
- Gossen Metrawatt
- Weltron
- Angler
- GW Instek
- PeakTech
- Megger
- Benning
- Mitsubishi
- Ade
- Jonard Tools
- H-Tronic
- Vimar
- DriveTest
- Homedics
- Testo
Nieuwste handleidingen voor Meetapparatuur
2 September 2025
2 September 2025
2 September 2025
2 September 2025
2 September 2025
2 September 2025
2 September 2025
1 September 2025
1 September 2025
1 September 2025