Bekijk gratis de handleiding van Samsung AM250TNBFGB (18 pagina’s), behorend tot de categorie Airco. Deze gids werd als nuttig beoordeeld door 117 mensen en kreeg gemiddeld 5.0 sterren uit 59 reviews. Heb je een vraag over Samsung AM250TNBFGB of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/18

Air conditioner
Installation manual
ADN***BDE** / AM***FNBD** / AM***FNBF** / AM***TNBF**
࡛Thank you for purchasing this Samsung Product.
࡛Before operating this unit, please read this manual carefully and retain it for future reference.

6
Safety precautions
CAUTION SIGNS
After completing the installation, run the trial operation. If no error occurs, explain to the customer how to use and clean the
air conditioner according to the user’s manual. In addition give the installation manual and the user’s manual to the customer.
Before the installation, check if the product is in good shape.
f Do not install the product with the damage which occurred during shipment.
All of the materials used to manufacture product and packages are eco-friendly and they are recyclable.
Refrigerant used in this product must be added or disposed in an appropriate way by qualied personnel.
f At the end of the life cycle, take it to a proper recycling or disposal center or return it to the dealer so that it can be
disposed correctly.
Combination rate
f This product should be connected with outdoor unit of the DVM S
f The combinations of the installation.
- This product should be combined among 50~130% of outdoor unit's capacity.
- When this product would be combined with heat pump outdoor units for 130~180% combination rate, it need to meet
the conditions below.
1) The combination rate for indoor units : Under the 100% of the A2A indoor units + Under the 80% of the DVM Hydro
unit/ Hydro unit HT.
2) A2A indoor units should be operated for cooling mode only, and DVM Hydro unit/ Hydro unit HT should be operated
for heating mode(including oor heating) only.
3) It is not possible to operate A2A indoor units and DVM Hydro unit/ Hydro unit HT at the same time.
- When combining an outdoor unit with an indoor unit, refer to the tables below for the capacity of DVM Hydro HT.
Capacity correction
AM160FNBF✴✴
AM160TNBF✴✴ 14.0kW
AM250FNBF✴✴
AM250TNBF✴✴ 22.4kW

7
ENGLISH
Preparing the installation
Tools required for installation
General tools
① Vacuum pump ② Torque wrench ③ Pipe cutter Pipe bender④ Reamer ⑤
⑥ ⑦ Spirit level Screw driver Spanner L wrench⑧ ⑨ Drill ⑩
Measuring tape
Tools for operation
① Thermometer ② Resistance meter ③ Electroscope
Accessories (supplied)
Before the installation, make sure to check if following accessories are included inside the DVM Hydro unit / Hydro unit HT.
Installation manual Drain plug Drain cap
Additional accessory (not included)
Additional accessory needs to be purchased separately and installed to operate DVM Hydro unit / Hydro unit HT.
[Model name of the wire remote controller: MWR-WW00N (All Model), MWR-WW10N (AM✴✴✴TNBF Model only)]
Wired remote controller
MWR-WW00N MWR-WW10N
f Recommended specication of the strainer
Model type Model name Work pressure Work
temperature
Water pipe
connection part Mesh size Material
(Strainer/Mesh)
HE
ADN160BDE✴✴
1.0 MPa
-5~48 °C
PT 1(25A)
50 Mesh AISI316/SUS304
ADN320BDE✴✴
AM160FNBD✴✴
AM320FNBD✴✴
ADN500BDE✴✴
PT 1-1/4(32A)
AM500FNBD✴✴
HT
AM✴✴✴FNBF
✴✴
AM✴✴✴TNBF
✴✴ -20 ~ 43 °C PT 1(25A)
Product specificaties
Merk: | Samsung |
Categorie: | Airco |
Model: | AM250TNBFGB |
Heb je hulp nodig?
Als je hulp nodig hebt met Samsung AM250TNBFGB stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Airco Samsung
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
Handleiding Airco
- Carson
- Just Fire
- ECG
- SPT
- Esatto
- Gorenje
- Thermex
- Airrex
- Svan
- Swegon
- Mestic
- Monzana
- Sonnenkonig
- Aspes
- Delonghi
Nieuwste handleidingen voor Airco
17 Juni 2025
17 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025
16 Juni 2025