Operations Manual
SHELFORD CHANNEL
Transformer Gain Mic Pre-amp
Inductor EQ
&
Diode Bridge Compressor
2
1. Read these instructions.
2. Keep these instructions.
3. Heed all warnings.
4. Follow all instructions.
5. Do not use this apparatus near water.
6. Clean only with a dry cloth.
7. Do not block any ventilation openings. Install in accordance with the
manufacturers instructions.
8. Do not install near any heat sources such as radiators, heat registers,
stoves, or other apparatus (including amplifiers) that produce heat.
9. Do not defeat the safety purpose of the polarized or grounding-type
plug. A polarized plug has two blades with one wider than the other.
A grounding-type plug has two blades and a third grounding prong.
The wide blade or the third prong are provided for your safety. If the
provided plug does not fit into your outlet, consult an electrician for
replacement of the obsolete outlet.
10.
Protect the power cord from being walked on or pinched particularly at
plugs, convenience receptacles, and the point where they exit from the
apparatus.
11.
Only use attachments/accessories specified by the manufacturer.
12.
Use only with a cart, stand, tripod, bracket, or
table specified by the manufacturer, or sold with
the apparatus. When a cart is used, use caution
when moving the cart/apparatus combination to
avoid injury from tip-over.
13.
Unplug this apparatus during lightning storms or
when unused for long periods of time.
14.
Refer all servicing to qualified service personnel. Servicing is required
when the apparatus has been damaged in any way, such as power-
supply cord or plug is damaged, liquid has been spilled or objects have
fallen into the apparatus, the apparatus has been exposed to rain or
moisture, does not operate normally, or has been dropped.
15.
This apparatus shall not be exposed to dripping or splashing, and no
object filled with liquids, such as vases or beer glasses, shall be placed
on the apparatus.
16.
Do not overload wall outlets and extension cords as this can result in a
risk of fire or electric shock.
17.
This apparatus has been designed with Class-I construction and must
be connected to a mains socket outlet with a protective earthing
connection (the third grounding prong).
18.
This apparatus has been equipped with a rocker-style AC mains power
switch. This switch is located on the rear panel and should remain
readily accessible to the user.
19.
The MAINS plug or an appliance coupler is used as the disconnect
device, so the disconnect device shall remain readily operable.
20. NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses, and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation.
If this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment o and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and the
receiver.
• Connect the equipment into an outlet on a circuit dierent from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
CAUTION: Changes or modifications to this device not expressly
approved by Rupert Neve Designs LLC, could void the user's authority to
operate the equipment under FCC rules.
21.
This apparatus does not exceed the Class A/Class B (whichever is
applicable)
limits for radio noise emissions from digital apparatus as
set out in the radio interference regulations of the Canadian Department
of Communications.
ATTENTION Le présent appareil numérique n’émet pas de bruits
radioélectriques dépassant las limites applicables aux appareils
numériques de class A/de class B (selon le cas) prescrites dans le
réglement sur le brouillage radioélectrique édicté par les ministere des
communications du Canada.
22.
Exposure to extremely high noise levels may cause permanent hearing
loss. Individuals vary considerably in susceptibility to noise-induced
hearing loss, but nearly everyone will lose some hearing if exposed to
sufficiently intense noise for a period of time. The U.S. Government’s
Occupational Safety and Health Administration (OSHA) has specified
the permissible noise level exposures shown in the following chart.
According to OSHA, any exposure in excess of these permissible limits
could result in some hearing loss. To ensure against potentially
dangerous exposure to high sound pressure levels, it is recommended
that all persons exposed to equipment capable of producing high
sound pressure levels use hearing protectors while the equipment
is in operation. Ear plugs or protectors in the ear canals or over the
ears must be worn when operating the equipment in order to prevent
permanent hearing loss if exposure is in excess of the limits set forth
here:
Important Safety Instructions
CAUTION AVIS
RISK OF ELECTRIC . DO NOT OPENSHOCK
RISQUE DE ELECTRIQUE. NE PAS OUVRIRCHOC
CAUTION: TO REDUCE THE RISK OF ELECTRIC SHOCK DO NOT REMOVE COVER (OR BACK)
NO USER-SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED PERSONNEL
ATTENTION: POUR EVITER LES RISQUES DE CHOC ELECTRIQUE, NE PAS ENLEVER LE COUVERCLE.
AUCUN ENTRETIEN DE PIECES INTERIEURES PAR L'USAGER.
CONFIER L'ENTRETIEN AU PERSONNEL QUALIFIE.
AVIS: POUR EVITER LES RISQUES D'INCENDIE OU D'ELECTROCUTION, N'EXPOSEZ PAS CET ARTICLE
A LA PLUIE OU A L'HUMIDITE
The lightning flash with arrowhead symbol within an equilateral triangle is
intended to alert the user to the presence of uninsulated "dangerous
voltage" within the product's enclosure, that may be of sufficient magnitude
to constitute a risk of electric shock to persons.
Le symbole éclair avec point de flèche à l'intérieur d'un triangle équilatéral
est utilisé pour alerter l'utilisateur de la présence à l'intérieur du coffret de
"voltage dangereux" non isolé d'ampleur suffisante pour constituer un risque
d'éléctrocution.
The exclamation point within an equilateral triangle is intended to alert the
user of the presence of important operating and maintenance (servicing)
instructions in the literature accompanying the appliance.
Le point d'exclamation à l'intérieur d'un triangle équilatéral est employé
pour alerter les utilisateurs de la présence d'instructions importantes pour le
fonctionnement et l'entretien (service) dans le livret d'instruction
accompagnant l'appareil. WARNING — To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.
Duration,
per day in
hours
Sound Level
dBA, Slow
Response
Typical Example
8 90 Duo in small club
6 92
4 95 Subway Train
3 97
2 100 Typical music via head phones
1.5 102
1 105 Siren at 10 m distance
0.5 110
0.25 or less 115 Loudest parts at a rock concert
PORTABLE CART
WARNING
3
Shelford Channel User Guide
Thank you for your purchase of the Shelford Channel.
Over fty years in the making, the Shelford Channel is the denitive evolution of
the original technologies in Rupert’s classic console modules like the 1073, 1064,
1081 & 2254, thoughtfully advanced and rened for the 21st century studio. The
Shelford Channel is built around Rupert Neve’s rst new transformer-gain, class-A
microphone preamplier in over 40 years, the “best-of-the-classics” inductor EQ
section from the Shelford 5051 and 5052, a tone-packed Diode Bridge Compressor,
the analog power of variable Silk saturation, a new dual-tap transformer output
stage for maintaining headroom or allowing the full driving of the Channel without
clipping standard converters, and twice the operating voltage of vintage designs.
With richly-colored tonal options for when bold statements are required, and
precisely-engineered detented controls for recall, the vintage-inspired Shelford
Channel maintains the soul of Rupert’s classic designs with new levels of versatility,
delivering what can only be described as the combined essence of fty years of
Rupert Neve’s designs.
Everyone at Rupert Neve Designs hopes that you enjoy using this tool as much as
we have enjoyed designing and building it.
Please take note of the safety concerns and power requirements before using this
product.
Shelford Channel: Block Diagram
0 - 66dB
PHN TM
PHA SE
Leve l Meter
HPF EN GA GE
STE PPED G A IN
+48V D C
2
3
4
1
M IN PUTIC
2
3
4
1
LIN E INPU T
M / LIN EIC
SILK
RE D/BL UE
TE XT URE
2 1
4
3
G
MA IN OU TPU T
EQ EN GA GE
GN D
GN D
GN D
GN D
-
LIN E T MRI
+
M PREIC
+ +
LV L
LV L
CO MPRE SSOR E NG AG E
+
GN D
EQ PRE/PO ST
+/-6dB CO N T.
FRE QU EN CY
FRE QU EN CY
QSHE LF /PE A K
LV L
SHE LF /PE A K
FRE QU EN CY
+/-15dB
+/-15dB +/-15dB200Hz
350Hz
700Hz
1.5kHz
3kHZ
6kHz
LO W Q
HIG H Q
35Hz
60Hz
100Hz
220Hz
SHE LF
PEA K
SHE LF
PEA K
8kHZ
16kHZ
LO W E Q HIG H EQ
LV L/RE D
S/ H PFC-
20-250H z
1
2
3
4
5
6
J?
SID E CH A IN SN D/RT N
+
HPF
1
2
3
4
5
6
J?
1
2
3
4
5
6
J?
D E CT INIR
+
D E CT INIR
2 1
4
3
G
-6dB O UT
1
2
3
4
5
6
J?
1
2
3
4
5
6
J?
LIN K
1
2
3
4
5
6
J?
LIN K
+
+
SC/IN SERT
-
+
+
C W
BL EN D
+
+
TIM IN G
FA ST
MF
ME D
MS
SLO W
A UT O
+
-
+
-6 TO 20dB
MA K E-U P GA IN
+
GN D
+
TH RESH OL D
+
V CA
RA TIO
1.5:1
2:1
3:1
4:1
6:1
8:1
+-
-
-33.5dB -8.5dB
-2.5dB


Product specificaties

Merk: Rupert Neve Designs
Categorie: Niet gecategoriseerd
Model: Shelford Channel

Heb je hulp nodig?

Als je hulp nodig hebt met Rupert Neve Designs Shelford Channel stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Rupert Neve Designs

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd