Digital Harpsichord Date: Sep. 1, 1998
C-80 Version 1.00MIDI IMPLEMENTATION
1. Receive data
Channel Voice Messages
Note o
Status 2nd byte 3rd byte
8nH kkH vvH
9nH kkH 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note o velocity: 00H-7FH (0-127)
Note on
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (0-127)
vv = note on velocity: 01H-7FH (1-127)
* Note numbers outside the range of 11-106 are transposed to the nearest octave within
this range.
* Transpose function does not aect the recognized note numbers.
Control Change
* The value specied by a Control Change message will not be reset even by a Program
Change, etc.
Data Entry (Controller number 6, 38)
Status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm, ll = the value of the parameter specied by RPN
* Data entry messages are recognized only when received on the basic channel.
Volume (Controller number 7)
Status 2nd byte 3rd byte
BnH 07H vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Volume: 00H-7FH (0-127), Initial Value = 7FH (127)
* Received volume messages aect received note event levels, and cannot aect internal
keyboard notes.
Expression (Controller number 11)
Status 2nd byte 3rd byte
BnH 0BH vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Expression: 00H-7FH (0-127), Initial Value = 7FH (127)
* These message can aect only MIDI notes.
Hold 1 (Controller number 64)
Status 2nd byte 3rd byte
BnH 40H vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Control value: 00H-7FH (0-127) 0-63 = OFF, 64-127 = ON
* These message can aect only MIDI notes.
RPN MSB/LSB (Controller number 100, 101)
Status 2nd byte 3rd byte
BnH 65H mmH
BnH 64H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = upper byte of parameter number specied by RPN
ll = lower byte of parameter number specied by RPN
* The value specied by RPN will not be reset even by messages such as Program Change
or Reset All Controller.
* RPN messages are recognized only when received on the basic channel.
**RPN**
The RPN (Registered Parameter Number) messages are expanded control changes, and each
function of an RPN is described by the MIDI Standard.
To use these messages, you must rst use RPN MSB and RPN LSB messages to specify the
parameter to be controlled, and then use Data Entry messages to specify the value of the
specied parameter. Once an RPN parameter has been specied, all Data Entry messages
received on that channel will modify the value of that parameter. To prevent accidents, it is
recommended that you set RPN Null (RPN Number = 7FH/7FH) when you have nished
setting the value of the desired parameter.
On the C-80, RPN can be used to modify the following parameters.
RPN Data entry
MSB LSB MSB LSB Explanation
00H 01H mmH llH Master Fine Tuning
mm, ll: 00 00H - 40 00H - 7F 7FH (-100 - 0 - +99.99
cents), Initial Value = 40 00H (+/-0 cent)
7FH 7FH --- --- RPN null
Set condition where RPN is unspecied. The
data entry messages after set RPN null will be
ignored. (No Data entry messages are required
after RPN null).
Settings already made will not change.
mm, ll: ignored
Copyright © 1999 ROLAND CORPORATION
All rights reserved. No part of this publication may be reproduced in any form without the written permission of ROLAND CORPORATION.
2
Program Change
Status 2nd byte
CnH ppH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
pp = Program number: 00H–37H (prog.1–prog.56)
Received program change message are assigned as follows.
prog. tone
1 Harpsichord 8'I
2 Harpsichord 8'II
3 Harpsichord 8'+8'
4 Harpsichord 8'+4'
5 Harpsichord Lute
6 Celesta
7 Organ I
8 Organ II
17 Celesta + Harpsichord 8'I
18 Celesta + Harpsichord 8'II
19 Celesta + Harpsichord 8'+8'
20 Celesta + Harpsichord 8'+4'
21 Celesta + Harpsichord Lute
22 Celesta
23 Celesta + Organ I
24 Celesta + Organ II
33 Organ I + Harpsichord 8'I
34 Organ I + Harpsichord 8'II
35 Organ I + Harpsichord 8'+8'
36 Organ I + Harpsichord 8'+4'
37 Organ I + Harpsichord Lute
38 Organ I + Celesta
39 Organ I
40 Organ II
49 Organ II + Harpsichord 8'I
50 Organ II + Harpsichord 8'II
51 Organ II + Harpsichord 8'+8'
52 Organ II + Harpsichord 8'+4'
53 Organ II + Harpsichord Lute
54 Organ II + Celesta
55 Organ I
56 Organ II
* '+' indicates a dual tone.
* Program numbers not in the above table are ignored.
* After a Program Change message is received, the sound will change beginning with the
next Note-on. Voices already sounding when the Program Change message was
received will not be aected.
* When the program change is received through the basic channel, the tone of this channel
part and the tone selected by the panel shall be changed to the designated tone.
Channel Mode Messages
Reset All Controllers (Controller number 121)
Status 2nd byte 3rd byte
BnH 79H 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
* When this message is received, the following controllers will be set to their reset values.
Controller Reset value
Expression 127 (max)
Hold 1 0 (o)
RPN unset; previously set data will not change
Local Control
Status 2nd byte 3rd byte
BnH 7BH 00H
BnH 7AH vvH
n=MIDI channel number: 0H - FH (ch.1 - ch.16)
vv=Value: 00H, 7FH (0, 127) 0=OFF 127=ON
All Notes O (Controller number 123)
Status 2nd byte 3rd byte
BnH 7BH 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
* When All Notes O is received, all notes on the corresponding channel will be turned
o. However if Hold 1 is ON, the sound will be continued until these are turned o.
OMNI OFF (Controller number 124)
Status 2nd byte 3rd byte
BnH 7CH 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
* The same processing will be carried out as when All Notes O is received.
OMNI ON (Controller number 125)
Status 2nd byte 3rd byte
BnH 7DH 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
* The same processing will be carried out as when All Notes O is received.
MONO (Controller number 126)
Status 2nd byte 3rd byte
BnH 7EH mmH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = mono number: 00H-10H (0-16)
* The same processing will be carried out as when All Notes O is received.
POLY (Controller number 127)
Status 2nd byte 3rd byte
BnH 7FH 00H
n = MIDI channel number: 0H-FH (ch.1-ch.16)
* The same processing will be carried out as when All Notes O is received.
System Realtime Message
Active Sensing
Status
FEH
* When Active Sensing is received, the unit will begin monitoring the intervals of all
further messages. While monitoring, if the interval between messages exceeds 380 ms,
the same processing will be carried out as when All Notes O and Reset All Controllers
are received, and message interval monitoring will be halted.
System Exclusive Message
Status Data byte Status
F0H iiH, ddH, ......,eeH F7H
F0H: System Exclusive Message status
ii = ID number: an ID number (manufacturer ID) to indicate the manufacturer whose
Exclusive message this is. Roland's manufacturer ID is 41H.
ID numbers 7EH and 7FH are extensions of the MIDI standard; Universal Non-realtime
Messages (7EH) and Universal Realtime Messages (7FH).
dd,...,ee = data: 00H-7FH (0-127)
F7H: EOX (End Of Exclusive)
The System Exclusive Messages received by the C-80 are; Universal Non-realtime System
Exclusive messages, and Data Set (DT1).
3
Universal Non-realtime System Exclusive Messages
Identity Request Message
Status Data byte Status
F0H 7FH, dev, 06H, 01H F7H
Byte Explanation
FOH Exclusive status
7FH ID number (universal non-realtime message)
dev Device ID (dev: UNIT#-1)
06H Sub ID#1 (General Information)
01H Sub ID#2 (Identity Request)
F7H EOX (End Of Exclusive)
* The “dev” is own device number (UNIT#-1) or 7FH (Broadcast).
* UNIT# is always the same as the current basic channel.
Data transmission
C-80 can transmit and receive the various parameters using System Exclusive messages.
The exclusive message of C-80 data has a model ID of 1AH, and device ID is dened by
MIDI UNIT NUMBER. UNIT NUMBER is always the same as the current basic channel.
Data set 1 (DT1)
This is the message that actually performs data transmission, and is used when you wish to
transmit the data.
Status Data byte Status
F0H 41H, dev, 1AH, 12H, aaH, bbH, ccH, sum F7H
Byte Explanation
F0H Exclusive status
41H ID number (Roland)
dev Device ID (dev: UNIT#-1)
1AH Model ID (C-80)
12H Command ID (DT1)
aaH Address MSB: upper byte of the starting address of the transmitted data
bbH Address LSB: lower byte of the starting address of the transmitted data
ccH Data: the actual data to be transmitted.
sum Checksum
F7H EOX (End Of Exclusive)
* If “Data Set 1 is transmitted successively, there must be an interval of at least 40 ms
between packets.
* Regarding the address please refer to section 3 (Parameter Address Map).
* Regarding the checksum please refer to section 4 (Supplementary material).
2. Transmit data
Channel Voice Messages
Note o
Status 2nd byte 3rd byte
8nH kkH vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (11-106)
vv = note o velocity: 00H-7FH (1-127)
Note on
Status 2nd byte 3rd byte
9nH kkH vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
kk = note number: 00H-7FH (11-106)
vv = note on velocity: 01H-7FH (1-127)
* Note number's range can be changed with Key Transpose and Octave Shift.
Control Change
* The value specied by a Control Change message will not be reset even by a Program
Change, etc.
Data Entry (Controller number 6, 38)
Status 2nd byte 3rd byte
BnH 06H mmH
BnH 26H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm, ll = the value of the parameter specied by RPN
* Data Entry is sent through the basic channel.
Hold 1 (Controller number 64)
Status 2nd byte 3rd byte
BnH 40H vvH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
vv = Control value: 00H,7FH (0, 127) 0 = OFF, 127 = ON
RPN MSB/LSB (Controller number 100, 101)
Status 2nd byte 3rd byte
BnH 65H mmH
BnH 64H llH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
mm = upper byte of parameter number specied by RPN
ll = lower byte of parameter number specied by RPN
* RPN is sent through the basic channel.
**RPN**
C-80 can transmit Master ne tuning (RPN #1) and RPN null. After sending the master ne
tune, immediately the RPN Null shall be sent.
RPN Data entry
MSB LSB MSB LSB Explanation
00H 01H mmH llH Master Fine Tuning
mm, ll: 20 00H - 40 00H - 5F 7FH (-50 - 0 - +49.99 cents)
7FH 7FH --- --- RPN null
Program Change
Status 2nd byte
CnH ppH
n = MIDI channel number: 0H-FH (ch.1-ch.16)
pp = Program number: 00H–34H (prog.1–prog.53)
When sounds are selected on the panel, the following program change messages will be
sent.
tone select button prog.
Harpsichord 8'I 1
Harpsichord 8'II 2
Harpsichord 8'+8' 3
Harpsichord 8'+4' 4
Harpsichord Lute 5
Celesta 6
Organ I 7
Organ II 8
Celesta + Harpsichord 8'I 17
Celesta + Harpsichord 8'II 18
Celesta + Harpsichord 8'+8' 19
Celesta + Harpsichord 8'+4' 20
Celesta + Harpsichord Lute 21
Celesta + Organ I 23
Celesta + Organ II 24
Organ I + Harpsichord 8'I 33
Organ I + Harpsichord 8'II 34
Organ I + Harpsichord 8'+8' 35
Organ I + Harpsichord 8'+4' 36
Organ I + Harpsichord Lute 37
Organ II + Harpsichord 8'I 49
Organ II + Harpsichord 8'II 50
Organ II + Harpsichord 8'+8' 51
Organ II + Harpsichord 8'+4' 52
Organ II + Harpsichord Lute 53


Product specificaties

Merk: Roland
Categorie: Niet gecategoriseerd
Model: C-80

Heb je hulp nodig?

Als je hulp nodig hebt met Roland C-80 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Roland

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd