INSTALLATION DATA
5500 M SERIES INFINITE SWITCH KIT
The Robertshaw
®
5500 M series is a voltage sensing (parallel circuit) innite
switch designed to replace the current VSI (INF) switch.
The Robertshaw® M Series Innite Switch is a rotary switch which controls
the power dissipated by a heang element. It is used on electric ranges, hot
plates, warming drawers and zones, barbecue grills, space heaters, quartz
resisve load.
The residenal model has the exclusive universal design of the square
break-o sha. Included with these kits are the sha adaptors that allow
the service person to use the customer’s original dial on the replacement
switch. The sha can be broken o to the required length to adapt to
numerous OEM applicaons.
The commercial model diers only in that it has a heavy-duty dial sha
(requiring no dial sha adaptors).
Specicaons:
UL Approved #E112536
15 Amps @ 120/240 Volt 50/60 Hz for 200°F (93°C) ambient
13 Amp rang for all temperatures up to maximum ambient of 257°F
(125°C)
Opons:
Push-to-Turn or Non-Push-to-Turn
Clockwise or Counterclockwise sha rotaon from OFF
Key Features:
Controllable range of output power with Lo and Hi detents
Compact and lightweight design
PANEL
ìVENTSUPî
FLATHEAD
SCREWS
Figure 3Figure 5
Figure 1
INSTALLATION INSTRUCTIONS
CAUTION:This device should be installed by a qualied service technician
with due regard for safety, as improper installaon could result in a
hazardous condion.
1. Unplug range or disconnect power.
2. Remove dial from switch.
3. Gain access to the inoperave switch. Refer to the original user manual
for the appliance for proper disassembly.
4. Label all wires with tags or make an exact drawing of wiring
conguraon before removing any wires.
5. Remove original switch.
6. Determine mounng type for the new switch: Screw Mount or Palnut.
Note:The 5500 M must be mounted with the sloed vents at the top.
Screw mount (Figure 1) is the most common. Aach the new switch to
the rear panel with the original screws or using the two athead screws
supplied in the kit.
Palnut mount (Figure 2) requires adding the bushing and the bracket
before inserng the sha through the rear panel. Use the two smaller
Phillips head screws to aached bracket vercally or horizontally to
the new switch. Secure the switch (nger snug) to the rear panel with
the palnut.
7. Temporarily mount the switch and place the original dial on the new
switch sha using one or more of the adaptors
on the sprue tree (Figure 3). Make sure the
sha goes in all the way. See Figure 4 for
assembly of spring clip to adaptor if applicable.
8. Measure distance from back of dial to the front
of the panel and subtract an 1/8”. This becomes your measurement
needed in the next step.
Figure 4
RESIDENTIAL MODEL
COMMERCIAL MODEL
PANEL
BUSHING
PALNUT
PHILLIPS
HEADSCREWS
BRACKET
(MOUNTVERTICALLY
ORHORIZONTALLY)
VENTSUP
Figure 2
9. Remove the switch. Use the measurement from previous step and
measuring from the end of the sha mark the sha at the nearest
break-o point (or at the next break-o groove toward the end of the
sha to avoid breaking o too short).
Note: If the control is push-to-turn and the sha is broken o too short
it will not allow the dial to detent as needed for proper operaon. The
control will need to be replaced as replacement shas are not available.
10. To break o the sha: Use two (2) pairs of pliers – one on each side of
the marked groove (Figure 5). Hold pliers rmly and break sha. DO
NOT HOLD SWITCH BODY.
11. Remount switch, then proceed to wiring instrucons.