用 户 手 册
Users Guide
© 2013 RIGOL Technologies, Inc. All Rights Reserved.
RP1010H高压示波器探头
High Voltage Probe for Oscilloscope
北京普源精电科技有限公司 RIGOL Technologies,Inc.
邮箱 : 网址E-mail service@rigol.com Website www.rigol.com
Warning
Do not attempt to take measurements from sources when
the chassis or return lead is not ground.
This ground connection is critical to the safety operation of
the probe. Failure to make this connection may result in
personal injuries or damages to the probe or voltmeter. This
connection must be made before the probe tip comes into
contact with the high voltage and must not be removed
until after the probe tip has been removed.
Do not connect the ground clip to the high voltage source or
the probe tip to the ground for any reason.
BEFORE turning the high voltage on, make sure that no
part of your body is in contact with the device.
Remembering that the voltage being measured is 1000
times greater than the voltmeter reading.
When the measuring voltage are DC 8 to 10 KV, or
AC rms 5 to 7 KV or AC peak 15 to 20 KV, do not
exceed 60 sec on each measurement. You can break off for
5 minutes at least during the measurement. Otherwise
overheating will affect the measurement accuracy even
damage the probe. Disconnect the probe tip from the high
voltage source removing the ground clip lead. BEFORE
Clean only the exterior probe body and cables. Use a soft
cotton cloth lightly moistened with a mild solution of
detergent and water. Do not submerge any portion of the
probe at any time.
Dry the probe thoroughly before any voltage measurement.
Make sure the probe is free from any solvents or solvent
fumes as these can case deterioration to the probe body and
cables.
When the measuring voltage is under
the followings. Each measurement
should be within 60 sec
.
You can break
off for 5 minutes at least during the
measurement.
DC: 8 ~ 10 KV
AC RMS: 5 ~ 7 KV
AC PEAK: 15~ 20 KV
当测量电压为下述情况时,每
次测量时间不得超过 期60秒。
间需断开并等待散热至少5分
钟。
直流:8 ~ 10 KV
交流 有效值: 5 ~ 7 KV
交流 峰峰值: 15 ~ 20 KV
!
Cleaning
性能指标 ( Specifications
最大工
作电压 Max. Working Voltage
DC: 0 ~ 10 KV DC
AC: pulse 20 KV peak to peak
AC: sine wave 7KV rms
信噪比 Signal/Noise DC 60 dB (1 KHz),
50 dB (1 MHz)
带宽 Bandwidth DC ~40 MHz (-3 dB)
衰减比例 Division Ratio 1:1000
上升时间 Rise Time 8.8 ns
输入阻抗 Input Impedance 100 M 5% Ω±
输入电容 Input Capacitance 3.0 pF ±0.5 pF
补偿范围 Compensation Range 5 pF ~ 50 p
F
线长度 Cable Length 2.0 meter ( 0.2 M) ±
温度系数 Temperature Coefficient ≤ ℃ 200 PPM /
精确度 Accuracy
DC
±3% (DC to
10 KV)
AC
± 3% (1 KHz/1 KV )
-3dB 40 MHz
安全认证 Safety App. CE
操作温度 Operating Temperature 0 ~ 50
存储温度 Storage Temperature -20 ~ +70
重量 尺寸/ Weight / Dimension 250 g /
Φ
75 x 340 L
mm
S M1 0 2 0 0 0 2 5 7 9
只需清洁探头外部的部位和导线。使用柔软的棉布
蘸取温和的清洁剂和清水轻轻擦拭探头。在任何时
候,不得将探头的任何部分浸没在清洁剂或水中。
使用探头进行电压测量前,请确保探头已经彻底干
燥。
避免探头受到溶剂或溶剂烟雾的影响,防止探头及
其连接线损坏。
This high voltage probe must only be operated by personnel
who are trained, experienced, or otherwise qualified to
recognize hazardous situations and who trained the safety
precautions that necessary to avoid possible injuries when
using such a device.
Do not work alone under the high voltage circuits.
For your own safety, inspect the probe for cracks and frayed
or broken leads before each use. If defects are noted, DO
NOT USE the probe.
Hands, shoes, floor and work bench must be dry. Do not
make any measurement under humid, damp or other situa-
tions that might affect the measurement safety.
If possible, do always turn off the high voltage source before
you connect or disconnect the probe.
The probe body should be kept clean and free of any conduc-
tive contamination.
Connect the divider probe common lead (alligator clip) to a
good earth ground or reliable ground.
Connect the BNC connector to the BNC input of your
oscilloscope.
Select a desired range for your oscilloscope. Whenever
possible, turn the high voltage source off before making any
connections.
RP1010H高压探头只允许以下人员使用:接受过培
训、富有经验、或能够识别危险状况的合格人员,
以及为避免产品使用过程中可能发生的危险,接受
过必要安全防护培训的人员。
使用高压电路时,操作人员应避免单独操作。
为了您的安全,每次使用探头前,请仔细检查是否
存在裂缝、磨损或导线损坏等现象。若发生上述情
况,请勿使用该探头。
使用本产品时,您的双手、鞋子、地板及工作台需
保持干燥。此外,应避免在潮湿及其他影响操作安
全的环境条件下进行测量。
只要条件允许,在连接或断开探头前,应确保高压
源处于关闭状态
探头表面应保持清洁,没有任何导电污染物。
确保探头的鳄鱼夹与地端接触良好、可靠。
将探头的 连接头插入示波器的 接口中。BNC BNC
调节示波器至所需测量量程。在进行任何连接前,
只要条件允许,应当确保高压源处于关闭状态
仪器机箱或回路线未接地时,不可进行任何带电测
试。
接地操作是安全使用探头的关键所在。一旦发生错
误,很可能导致人员伤害或致使探头以及电压表损
坏。在探针与高压源连接前必须完成接地操作,探
针移除前不得改变接地状态。
任何情况下,不得将接地夹连接至高压源中,或将
探针与地相连。
开启高压源之前,应确保操作人员身体的任何部位
均未与仪器接触
所测电压的实际数值是电压表读数的1000倍。当所
测电压为 (直流), (交流 有8 ~ 10 KV 5 ~ 7 KV
效值)或者 (交流 峰峰值)时,每次15 ~ 20 KV
测量不得超过 秒。期间需断开并等待散热至少560
分钟。否则,过热影响测量精度甚至损坏。在移除
接地夹导线前,需断开探针与高压源的连接。
安全措施
使用方法 清洁
警告
Operation
Safety Precautions


Product specificaties

Merk: Rigol
Categorie: Niet gecategoriseerd
Model: RP1010H

Heb je hulp nodig?

Als je hulp nodig hebt met Rigol RP1010H stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Niet gecategoriseerd Rigol

Rigol

Rigol RM-DG Handleiding

11 Januari 2024
Rigol

Rigol PVP2150 Handleiding

9 Januari 2024
Rigol

Rigol PVP3150 Handleiding

27 November 2023
Rigol

Rigol PHA2150 Handleiding

27 November 2023
Rigol

Rigol RP7150S Handleiding

27 November 2023
Rigol

Rigol PVP2350 Handleiding

27 November 2023
Rigol

Rigol PVA8700 Handleiding

27 November 2023
Rigol

Rigol RP5600A Handleiding

27 November 2023
Rigol

Rigol RP1010H Handleiding

27 November 2023

Handleiding Niet gecategoriseerd

Nieuwste handleidingen voor Niet gecategoriseerd