MAINTENANCE
INSTRUCTIONS
1-Once a year, remove the dust accumulation inside the heater using
a vacuum cleaner or compressed air.
2-Cleaning should be done while the heater is disconnected
from the supply circuit. Wait until the housing and heating element
cool before performing maintenance.
3-Iftheheaterhasanairlter,checkthelteronceamonth.
UseonlyaUL900approvedairlterofgradeMerv8orless.
193/4in.x113/4in.x7/8in.(501mmx298mmx22mm).
4-Anyotherservicingshouldbeperformedbyaqualied
technician.
5-Themotorisatotallyenclosedcasingwithballbearingsinsidethat
doesnt need lubrication.
INS680-202210-03
Read carefullythese instructions before installation, operation of the
heater.Failuretoadheretotheinstructionscouldresultinre,electric
shock,seriouspersonalinjury,anddeathorpropertydamage.Review
frequently for continuing safe operation and instruction of future users,
if necessary.
IMPORTANT
INSTRUCTIONS
1- Read all instructions before installing or using this heater.
2-Thisheaterishotwheninuse.Toavoidburns,donotletbareskin
touch hot surfaces.
3-This heater is designed to be used in the space between a structural
ceiling and a suspended ceiling, plenum space or plenum.
4-Do not operate any heater after it malfunctions. Disconnect power
at service panel and have heater inspected by a reputable electrician
before reusing.
5-Donotuseoutdoors.
6-Donotinsertorallowforeignobjectstoenteranyventilationor
exhaustopeningasthismaycauseanelectricshockorre,or
damage the heater.
7-Topreventapossiblere,donotblockairintakesorexhaustinany
way whatsoever.
8-Todisconnectheater,operateinternaldisconnectswitchorturno
power at main disconnect panel.
9-Thisheaterhashotandarcingorsparkingpartsinside.Donotuse
itinareaswheregasoline,paint,orammablevaporsorliquidsare
used or stored.
10- Use this heater only as described in this manual. Any other use not
recommendedbythemanufacturermaycausere,electricshock,or
injurytopersons.
11-Theheaterhasbeendesignedandcertiedforambientheatingonly.
Themaximumambientoperatingtemperatureis30°C(86°F).
12-The heater is not designed for use in a humid environment where
condensation may form on the device.
13- The thermostat should not be considered an infallible device in cases
where maintaining a temperature is considered critical. Examples:
Hazardous material storage, computer server room, etc. In these
particular cases, it is imperative to add a monitoring system to avoid
the consequences of a thermostat failure.
SAVE THESE
INSTRUCTIONS
OPERATING
INSTRUCTIONS
1-The heater must be properly installed before it is used.
2-Turnthepoweronatthecircuitbreakerpanel.
3-Low voltage electronic wall thermostat:
-Besuretocongurethethermostatinheatingmodewithfan.
-Adjustthetemperaturesetpointinthethermostat.
4-Built-inthermostatwithcontrolknoboptional.
To set thermostat at the desired temperature, follow these steps:
-Setthermostatatmaximumtemperature(turnclockwise).
-When the desired temperature is reached, turn the thermostat
counter-clockwiseslowlyuntilyouhearaclick.
-Thethermostatwillkeepthisroomtemperature.
START UP
-On a call for heat from either the remote thermostat or the unit
mounted thermostat the elements and fan will be energized.
-When the set thermostat is reached the elements will be deenergized.
-The fan will continue to run until the residual heat is removed from
the heater. Then the fan will stop.
OVERTEMPERATURE PROTECTION
-The motor and the electric heating elements are protected against
overtheat by an automatic reset thermal high-limit.
-A manual reset thermal high-limit is present for elements in case of
failure of the automatic reset thermal high-limit.
-Cycling of either thermal high-limit indicates abnormal operation of
theheaterandmustbexedimmediately.
MANUAL RESEST HI-LIMIT RESUMING
- Disconnect all power supplies.
- Remove the side panel.
- Unscrew the cap and push the reset button on the hi-limit body inside
theconnectionsboxtoresetthehi-limit(Figure6).
-Screwbackthecap.
-Replacebackthesidepanel.
-Turnthepowerbackon.
LUBRIFICATION OF MOTOR
The motor is a totally enclosed casing with ball bearings inside that
doesnt need lubrication.
MOTOR TRANSFORMER FUSES REPLACEMENT
-Disconnect all power supplies.
-Openthemotoraccesspanel(Figure1).
-Change fuses and respect the current rating as well as the model
required(Figure1).
-Close the motor access panel.
-Turnthepowerbackon.
WARNING
When using electrical appliances, basic precautions should always
betakentoreducetheriskofre,electricalshockandinjury,
including the following
.
Figure 1
Reznor LLC, Saint Charles, MO
Tel.:1800695-1901/www.ReznorHVAC.com
©2026Reznor,LLC.Allrightsreserved.Allothertrademarks
are the property of their respective organizations.
M ()odelEPH 3kW to 5kW