MAINTENANCE
INSTRUCTIONS
1-Once a year, remove the dust accumulation inside the heater using
a vacuum cleaner or compressed air.
2-Cleaning should be done while the heater is disconnected
from the supply circuit. Wait until the housing and heating element
cool before performing maintenance.
3-Iftheheaterhasanairlter,checkthelteronceamonth.
UseonlyaUL900approvedairlterofgradeMerv8orless.
Maximum actual dimensions must be
193/4in.x113/4in.x7/8in.(501mmx298mmx22mm).
4-Anyotherservicingshouldbeperformedbyaqualied
technician.
5-Themotorisatotallyenclosedcasingwithballbearingsinsidethat
doesn’t need lubrication.
INS680-202210-03
Read carefullythese instructions before installation, operation of the
heater.Failuretoadheretotheinstructionscouldresultinre,electric
shock,seriouspersonalinjury,anddeathorpropertydamage.Review
frequently for continuing safe operation and instruction of future users,
if necessary.
IMPORTANT
INSTRUCTIONS
1- Read all instructions before installing or using this heater.
2-Thisheaterishotwheninuse.Toavoidburns,donotletbareskin
touch hot surfaces.
3-This heater is designed to be used in the space between a structural
ceiling and a suspended ceiling, plenum space or plenum.
4-Do not operate any heater after it malfunctions. Disconnect power
at service panel and have heater inspected by a reputable electrician
before reusing.
5-Donotuseoutdoors.
6-Donotinsertorallowforeignobjectstoenteranyventilationor
exhaustopeningasthismaycauseanelectricshockorre,or
damage the heater.
7-Topreventapossiblere,donotblockairintakesorexhaustinany
way whatsoever.
8-Todisconnectheater,operateinternaldisconnectswitchorturno
power at main disconnect panel.
9-Thisheaterhashotandarcingorsparkingpartsinside.Donotuse
itinareaswheregasoline,paint,orammablevaporsorliquidsare
used or stored.
10- Use this heater only as described in this manual. Any other use not
recommendedbythemanufacturermaycausere,electricshock,or
injurytopersons.
11-Theheaterhasbeendesignedandcertiedforambientheatingonly.
Themaximumambientoperatingtemperatureis30°C(86°F).
12-The heater is not designed for use in a humid environment where
condensation may form on the device.
13- The thermostat should not be considered an infallible device in cases
where maintaining a temperature is considered critical. Examples:
Hazardous material storage, computer server room, etc. In these
particular cases, it is imperative to add a monitoring system to avoid
the consequences of a thermostat failure.
SAVE THESE
INSTRUCTIONS
OPERATING
INSTRUCTIONS
1-The heater must be properly installed before it is used.
2-Turnthepoweronatthecircuitbreakerpanel.
3-Low voltage electronic wall thermostat:
-Besuretocongurethethermostatinheatingmodewithfan.
-Adjustthetemperaturesetpointinthethermostat.
4-Built-inthermostatwithcontrolknoboptional.
To set thermostat at the desired temperature, follow these steps:
-Setthermostatatmaximumtemperature(turnclockwise).
-When the desired temperature is reached, turn the thermostat
counter-clockwiseslowlyuntilyouhearaclick.
-Thethermostatwillkeepthisroomtemperature.
START UP
-On a call for heat from either the remote thermostat or the unit
mounted thermostat the elements and fan will be energized.
-When the set thermostat is reached the elements will be deenergized.
-The fan will continue to run until the residual heat is removed from
the heater. Then the fan will stop.
OVERTEMPERATURE PROTECTION
-The motor and the electric heating elements are protected against
overtheat by an automatic reset thermal high-limit.
-A manual reset thermal high-limit is present for elements in case of
failure of the automatic reset thermal high-limit.
-Cycling of either thermal high-limit indicates abnormal operation of
theheaterandmustbexedimmediately.
MANUAL RESEST HI-LIMIT RESUMING
- Disconnect all power supplies.
- Remove the side panel.
- Unscrew the cap and push the reset button on the hi-limit body inside
theconnectionsboxtoresetthehi-limit(Figure6).
-Screwbackthecap.
-Replacebackthesidepanel.
-Turnthepowerbackon.
LUBRIFICATION OF MOTOR
The motor is a totally enclosed casing with ball bearings inside that
doesn’t need lubrication.
MOTOR TRANSFORMER FUSES REPLACEMENT
-Disconnect all power supplies.
-Openthemotoraccesspanel(Figure1).
-Change fuses and respect the current rating as well as the model
required(Figure1).
-Close the motor access panel.
-Turnthepowerbackon.
WARNING
When using electrical appliances, basic precautions should always
betakentoreducetheriskofre,electricalshockandinjury,
including the following
.
Figure 1
Reznor LLC, Saint Charles, MO
Tel.:1800695-1901/www.ReznorHVAC.com
©2026Reznor,LLC.Allrightsreserved.Allothertrademarks
are the property of their respective organizations.
M ()odelEPH 3kW to 5kW
Product specificaties
| Merk: | Reznor |
| Categorie: | Heater |
| Model: | EPH |
Heb je hulp nodig?
Als je hulp nodig hebt met Reznor EPH stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Heater Reznor
19 Mei 2026
28 Januari 2026
28 Januari 2026
27 Januari 2026
26 Januari 2026
2 December 2025
20 Februari 2025
20 Februari 2025
20 Februari 2025
20 Februari 2025
Handleiding Heater
Nieuwste handleidingen voor Heater
19 Mei 2026
19 Mei 2026
19 Mei 2026
19 Mei 2026
19 Mei 2026
18 Mei 2026
18 Mei 2026
15 Mei 2026
14 Mei 2026
14 Mei 2026