• Ensure that only a qualified electrician installs/services this
equipment.
•
• Ensure that power supply voltage does not exceed maximum
voltage rating of reel.
•
• Ensure that all electrical power is removed from reel before
servicing.
•
• A high-tension spring assembly is contained within the reel.
Exercise extreme caution.
•
electrical cord from reel by grasping the electrical cord itself,
not the work device.
•
• If an electrical malfunction should occur, remove power from
reel immediately.
• Ensure that reel, electrical cord, and equipment being serviced
are properly grounded. Use an ohmmeter to check ground
continuity.
•
• If reel ceases to unwind or rewind, remove power immediately.
Do not pull or jerk on electrical cord!
•
• Treat and respect the reel as any other piece of machinery,
observing all common safety practices.
•
• All cord reels with flying leads must be hard wired into the
electrical circuit to ensure proper function.
•
WARNING: Even low voltage can cause irreparable damage or
death! Exercise extreme caution while operating or servicing this
equipment.
SAFETY
Personal injury and/or equipment damage may result if proper safety
precautions are not observed.
Read this manual carefully before installing,
operating or servicing this equipment.
IMPORTANT
Operating Instructions
Reelcraft Industries, Inc. • 2842 E Business Hwy 30, Columbia City, IN 46725
Ph: 800-444-3134 / 260-248-8188 • Fax: 800-444-4587 / 260-248-2605
Customer Service: 855-634-9109 • [email protected] • www.reelcraft.com
Form# 1287-916 Rev: 9/2023
Dimensions
A20 1/4”
B19 3/4”
C7 7/8”
D3 7/8”
E12 1/2”
Series L 70000 Spring Driven Cord Reels
Model Numbers:
L 70075 123 3L 70100 123 3BL 70100 123 9G
L 70100 123 3L 70100 123 7AL 70100 123 X
L 70075 123 3AL 70100 123 7QCL 70100
L 70075 123 3ACL 70075 123 9L 70100 124 X
L 70100 123 3AL 70100 123 9L 70100 124
Series L 70000 Spring Driven Cord Reels
Page 2
www.reelcraft.com
Installation Instructions
Mounting
CAUTION:
Unless reel was specified differently when ordering, maximum
installation height is 16 feet. Do not exceed this distance. Ensure that
only a qualified electrician installs/services this equipment. Observe
applicable NEC, OSHA, and local codes when installing this equipment.
Installation of GFCI cord reels should be performed by a qualified and
licensed professional in accordance with local building codes and
applicable NEC standards.
1. Unpack and inspect the reel for damage. Turn by hand to check for
smooth operation. Check for completeness.
2. Configure reel for top, side or bottom-wind (bottom-wind for
constant tension reels only) electrical cable dispensing by
removing bolts (1) securing guide arm bracket (2).
3. Determine new guide arm bracket location and remove
corresponding bolts. Position guide arm bracket to reel and
replace bolts.
4. Position reel on floor, wall or ceiling. Secure into place using four
(customer supplied) screws or bolts (3).
Installing the Input Electrical Cable:
15 and 20 AMP Models
WARNING:
Use only 12/3 or 12/4 SEOOW cable for input wiring. Ensure that
application does not exceed electrical rating of reel.
1. Feed input cable through elbow (not pictured) and main shaft.
Make sure that input cable extends 6” from collector.
2. Screw elbow (not pictured) into reel.
3. Connect input wires and collector ring wires together using
splicing connectors (7).
4. Take the provided zip tie (not pictured) and zip tie the input cable
wires together closest to the slip ring.
5. Assemble cover (9) to reel.
Installing the Output Electrical Cable:
15 and 20 AMP Models
WARNING:
to be supplied. Ensure that application does not exceed electrical rating
of reel. Use extreme caution, reel under tension. Avoid releasing latch
mechanism.
1. Manually turn sheave (4) until spring is tight, back off 2 turns, and
latch.
2. Remove access cover (9).
3. Remove 6” of output cable outer jacket (3).
4. Route cable through strain relief (1), then through cut out in spool
(4).
5. Pull enough cable through for roughly 1/2 an inner wrap. Route
cable behind the brush holder (10), then route cable through the
two cable clamps (8) securing it in place.
6. Connect output wires with splicing connectors (7) as shown.
7. Connect ground wire to grounding stud (6) as shown.
8. Using Ohmmeter check for ground faults.
9. Replace cover (9).
10. Release latch and wind cable onto reel.
11. Install bumper stop (2).
Series L 70000 Spring Driven Cord Reels
www.reelcraft.com
Page 3
Replacing the Output Cord/Work Device (figure A)
WARNING:
Remove power from reel before performing any of the following
procedures.Use extreme caution, reel under tension. Avoid releasing
latch mechanism.
1. Pull output electrical cord from reel until fully extended, then latch.
2. Remove output electrical bumper stop (2).
3. Disconnect output electrical cord/work device (3) at splicing
connectors (5).
4. Remove strain relief (1). Remove output electrical cord/work
device.
5. Install replacement electrical cord/work device by reversing steps
2 through 4.
6. Release latch and rewind electrical cord on reel.
7. Replace access cover (9).
Replacing the Input Cord (figure A)
WARNING:
All cord reels with GFCI receptacles must be hard wired into the
electrical circuits. Use of 2 or 3 prong plugs may cause a potential
malfunction of the GFCI receptacle.
1. Remove splicing connectors (15) securing input electrical cord to
collector assembly (10).
2. Remove 90 degree elbow (not pictured).
3. Remove input electrical cord.
4. Remove 11” of outer jacket from replacement input electrical cord
(input electrical cord wires must protrude a minimum of 6” from
center of collector assembly).
5. Install replacement input electrical cord by reversing steps 1
through 3.
6. Replace access cover (9).
Replacing the Brush Holder/Brushes (figure A)
1. At splicing connectors (7), remove wires connecting brushes (3) to
outlet wire.
2. Remove nuts holding brush holder (10) to reel. Relocate cable
clamp (8) temporarily and remove brush holder (10)
3. Remove brushes from brush holder (10).
4. Install replacement brush holder (10) and brushes (12) by
reversing steps 1 through 3. Upon completion of installation,
ensure good contact between new brush installation and ring.