Premium Levella PFR12401G Handleiding


Bekijk gratis de handleiding van Premium Levella PFR12401G (8 pagina’s), behorend tot de categorie Vriezer. Deze gids werd als nuttig beoordeeld door 6 mensen en kreeg gemiddeld 3.5 sterren uit 3.5 reviews. Heb je een vraag over Premium Levella PFR12401G of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/8
P F 0 GR 7 0
M o d e M o d e ll / o :
P
F 0 G P F 1 GR 5 9 R 5 9 0
P F 0 GR 7 4
P F 2 G P F 0 GR 7 4 R 9 5
P F 2 G P F 0 GR 9 5 R 1 0 9
P F 2 G P F 0 G R 1 0 9 R 1 2 4
P F 1 GR 1 2 4 0
Transportation and Placement
When transporting the chest freezer from one place to another, the inclination of the
cabinet should not exceed 45 degrees, for prevention against compressor or system
damage.
Before use, remove all the packing material. The back side of the cabinet should be more
than 20cm away from the wall, both sides more than 20cm away from any adjacent
cabinet or wall.
The freezer should be put in a well-ventilated, dry place. Do not place it under direct
sunshine. The freezer should be kept away from water sinks, heat sources and any
volatile or corrosive material.
Power source and test-running
Specified capacity of the wire is 7A. Section of the wire is 0.82mm². Single line or
compound lines are all allowed. A fuse of 2.5A specified electric current should be installed.
(Power cord should be replaced with the same of 7A and 0.82mm², when it is damaged).
Single-phase power supply, 60Hz, voltage range 98~132V. If the voltage is unstable,
please install a voltage stabilizer with capacity above 1000W.
Avoid turning the power on and off too frequently. If the power is turned off, wait an interval
of 5 minutes before turning it on again.
When the freezer will be out of use for a long time, disconnect the power first, then clean it.
Please examine the circuit before reuse.
Caution:
1.Risk of fire / flammable materials, taking care to avoid causing a fire by igniting flammable
material.
2.Keep clear of obstruction all ventilation openings in the appliance enclosure or in the structure for
building-in.
3.Do not use mechanical devices or other means to accelerate the defrosting process, other than those
recommended by the manufacturer.
4.Do not damage the refrigerant circuit.
5.Do not use electrical appliances inside the food storage compartments of the appliance, unless they
are of the type recommended by the manufacturer.
6.The ambient temperature and humidity conditions of the cooler climate class following the tab below:
Test room
climate class
Dry bulb
temperature ( C)
Relative Humidity
(%)
Dew point ( C)
Water vapor mass in dry
air (g/kg)
0
20
50
9.3
7.3
1
16
80
12.6
9.1
8
23.9
55
14.3
10.2
2
22
65
15.2
10.8
3
25
60
16.7
12.0
4
30
55
20.0
14.8
6
27
75
21.1
15.8
Caution for Safety
Warning! Do not damage the cooling fluid circuit
Warning! Do not damage walls of the machine: the cooling fluid circuit may damage
Warning! Do not use electrical appliances inside the food storage compartments of the appliance, unless
they are of the type recommended by the manufacturer.
Warning! The equipment must not be used by persons (including children) whose physical, sensorial, or
mental capacities are reduced, or who lack experience and know-how, unless they have been provided,
by means of a person responsible for their safety, with suitable monitoring or instructions about the use
of the equipment. Children must be monitored to ensure they do not play with the equipment.
Warning! Keep clear of obstruction all ventilation openings in the appliance enclosure or in the
structure for building-in
Warning! The appliance shall be installed in accordance with national wiring regulations.
Warning! Do not use means to accelerate the defrosting process or to clean, other than those
recommended by the manufacturer.
Warning! The appliance shall be stored in a well-ventilated area where the room size corresponds to
the room area as specified for operation.
Warning! The appliance shall be stored in a room without continuously operating open flames (for
example an operating gas appliance) and ignition sources (for example an operating electric heater).
Do not pierce or burn.
Be aware that refrigerants may not contain an odour.
Warning! The appliance shall be stored so as to prevent mechanical damage from occurring.
Warning! Do not store explosive substances such as aerosol cans with a flammable propellant in this
appliance.
Notice! Any person who is involved with working on or breaking into a refrigerant circuit should hold a
current valid certificate from an industry-accredited assessment authority, which authorizes their
competence to handle refrigerants safely in accordance with an industry recognized assessment
specification.
Notice! Servicing shall only be performed as recommended by the equipment manufacturer.
Maintenance and repair requiring the assistance of other skilled personnel shall be carried out under
the supervision of the person competent in the use of flammable refrigerants.
Notice! Component parts shall be replaced with like components so as to minimize the risk of
possible ignition due to incorrect parts.The appliance is to be installed in accordance with the Safety
5
40
40
23.9
18.8
7
35
75
30.0
27.3
NOTE: the water vapor mass in dry air is one of the main points influencing the performance and the
energy consumption of the freezers. Therefore, the order of the climate class in the table is based on
the water vapor mass column.
Refrigerant class A3 per ANSI/ASHRAE 34


Product specificaties

Merk: Premium Levella
Categorie: Vriezer
Model: PFR12401G

Heb je hulp nodig?

Als je hulp nodig hebt met Premium Levella PFR12401G stel dan hieronder een vraag en andere gebruikers zullen je antwoorden