Power Dynamics 172.626 Handleiding


Lees hieronder de 📖 handleiding in het Nederlandse voor Power Dynamics 172.626 (24 pagina's) in de categorie Mengpaneel. Deze handleiding was nuttig voor 37 personen en werd door 2 gebruikers gemiddeld met 4.5 sterren beoordeeld

Pagina 1/24
PDM-Series Stage Mixers
Ref. nr.: 172.620; 172.622; 172.624; 172.626
INSTRUCTION MANUAL
GEBRUIKSAANWIJZING
BEDIENUNGSANLEITUNG
MANUAL DE INSTRUCCIONES
MANUEL D'INSTRUCTIONS
INSTRUKCJA OBSŁUGI
V1.2
2
ENGLISH
Congratulations to the purchase of this Power Dynamics product. Please read this manual thoroughly prior to using the unit in
order to benefit fully from all features.
Read the manual prior to using the unit. Follow the instructions in order not to invalidate the warranty. Take all precautions to
avoid fire and/or electrical shock. Repairs must only be carried out by a qualified technician in order to avoid electrical shock.
Keep the manual for future reference.
- Prior to using the unit, please ask advice from a
specialist. When the unit is switched on for the first time,
some smell may occur. This is normal and will disappear
after a while.
- The unit contains voltage carrying parts. Therefore do
NOT open the housing.
- Do not place metal objects or pour liquids into the unit
This may cause electrical shock and malfunction.
- Do not place the unit near heat sources such as
radiators, etc. Do not place the unit on a vibrating
surface. Do not cover the ventilation holes.
- The unit is not suitable for continuous use.
- Be careful with the mains lead and do not damage it. A
faulty or damaged mains lead can cause electrical shock
and malfunction.
- When unplugging the unit from a mains outlet, always
pull the plug, never the lead.
- Do not plug or unplug the unit with wet hands.
- If the plug and/or the mains lead are damaged, they
need to be replaced by a qualified technician.
- If the unit is damaged to such an extent that internal
parts are visible, do NOT plug the unit into a mains outlet
and DO NOT switch the unit on. Contact your dealer. Do
NOT connect the unit to a rheostat or dimmer.
- To avoid fire and shock hazard, do not expose the unit to
rain and moisture.
- All repairs should be carried out by a qualified technician
only.
- Connect the unit to an earthed mains outlet (220-
240Vac/50Hz) protected by a 10-16A fuse.
- During a thunderstorm or if the unit will not be used for a
longer period of time, unplug it from the mains. The rule
is: Unplug it from the mains when not in use.
- If the unit has not been used for a longer period of time,
condensation may occur. Let the unit reach room
temperature before you switch it on. Never use the unit in
humid rooms or outdoors.
- To prevent accidents in companies, you must follow the
applicable guide lines and follow the instructions.
- Do not repeatedly switch the fixture on and off. This
shortens the life time.
- Keep the unit out of the reach of children. Do not leave
the unit unattended.
- Do not use cleaning sprays to clean switches. The
residues of these sprays cause deposits of dust and
grease. In case of malfunction, always seek advice from
a specialist.
- Do not force the controls.
- This unit is with speaker inside which can cause
magnetic field. Keep this unit at least 60cm away from
computer or TV.
- This unit is with built-in lead-acid rechargeable battery.
Please recharge the battery every 3 months if you are
not going to use the unit for a long period of time. Or the
battery may be damaged.
- If the battery is damaged please replace with same
specifications battery. And dispose the damaged battery
environment friendly.
- If the unit has fallen, always have it checked by a
qualified technician before you switch the unit on again.
- Do not use chemicals to clean the unit. They damage the
varnish. Only clean the unit with a dry cloth.
- Keep away from electronic equipment that may cause
interference.
- Only use original spares for repairs, otherwise serious
damage and/or dangerous radiation may occur.
- Switch the unit off prior to unplugging it from the mains
and/or other equipment. Unplug all leads and cables
prior to moving the unit.
- Make sure that the mains lead cannot be damaged when
people walk on it. Check the mains lead before every use
for damages and faults!
- The mains voltage is 220-240Vac/50Hz. Check if power
outlet match. If you travel, make sure that the mains
voltage of the country is suitable for this unit.
- Keep the original packing material so that you can
transport the unit in safe conditions.
This mark attracts the attention of the user to high voltages that are present inside the housing and that are of sufficient
magnitude to cause a shock hazard.
This mark attracts the attention of the user to important instructions that are contained in the manual and that he should
read and adhere to.
The unit has been certified CE. It is prohibited to make any changes to the unit. They would invalidate the CE certificate and
their guarantee!
NOTE: To make sure that the unit will function normally, it must be used in rooms with a temperature between 5°C/41°F and
35°C/95°F.
Electric products must not be put into household waste. Please bring them to a recycling centre. Ask your local authorities or your
dealer about the way to proceed. The specifications are typical. The actual values can slightly change from one unit to the other.
Specifications can be changed without prior notice.
Do not attempt to make any repairs yourself. This would invalid your warranty. Do not make any changes to the unit. This would also invalid
your warranty. The warranty is not applicable in case of accidents or damages caused by inappropriate use or disrespect of the warnings
contained in this manual. Power Dynamics cannot be held responsible for personal injuries caused by a disrespect of the safety
recommendations and warnings. This is also applicable to all damages in whatever form.
3
UNPACKING INSTRUCTION
CAUTION! Immediately upon receiving the product, carefully unpack the carton, check the contents to ensure that all parts are
present, and have been received in good condition. Notify the shipper immediately and retain packing material for inspection if
any parts appear damage from shipping or the package itself shows signs of mishandling. Save the package and all packing
materials. In the event that the product must be returned to the factory, it is important that the product be returned in the original
factory box and packing.
If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The
arising condensation water might damage your device. Leave the device switched off until it has reached room temperature.
POWERSUPPLY
On the label on the backside of the product is indicated on this type of power supply must be connected. Check that the mains
voltage corresponds to this, all other voltages than specified, the product be irreparably damaged. The product must also be
directly connected to the mains and may be used. No dimmer or adjustable power supply.
Always connect the device to a protected circuit (circuit breaker or fuse). Make sure the device has an appropriate
electrical ground to avoid the risk of electrocution or fire.
CONTROL ELEMENTS
1. TRIM Control
Adjusts the input signal level. To get the best balance between the S/N ratio and the dynamic
range, adjust the gain so that the peak indicator (8) lights only occasionally and briefly on the
highest input transients. The -60 to +10 scale is the MIC input adjustment range. The 40 to +10
scale is the line input adjustment range.
2. Low Out Switch
This switch toggles the HPF on or off. To turn the HPF on, the HPF cuts frequencies below
75Hz.
3. Equalizer
Three-band equalizer adjusts the channel's high, mid and low frequency bands. Setting the
knob to the "O" position produces a fiat response in the corresponding band. Turning the knob
to the right boosts the corresponding frequency band, while turning to the left attenuates the
band.
4. Aux Control
Monitor and effect busses (Aux sends) source their signals via a control from one or more
channels and sum these signals to a so-called bus. This bus signal is sent to an aux send
connector (for monitoring applications: Mon Out) and then routed, for example, to an active
monitor speaker or external effect device. In the latter case, the effects return can then be
brought back into the console via the aux return connectors. All monitor and effect busses are
mono, are tapped into post EQ and offer amplification of up to +15dB.
5. FX Control
The aux send marked FX offers a direct route to the built-in effects processor and is therefore
post-fader and post-mute.
6. PAN Control
The PAN control determines the position of the channel signal within the stereo image. When
working with subgroups, you can use the PAN control to assign the signal to just one output,
which gives you additional flexibility in recording situations.
7. ON/OFF Switch
Turn this switch on to send the signal to master. The switch lights when on.
8. Peak LED
The peak-led lights up when the input signal is driven too high. If this happens, back off the Trim
control and, if necessary, check the setting of the channel EQ.
9. Solo Switch
The solo switch is used to route the channel signal to the solo bus (Solo In Place) or to the PFL
bus (Pre Fader Listen). This enables you to listen to a channel signal without affecting the main
output signal. The signal you hear is taken either before the pan control (PFL, mono) or after the
pan and channel fader.
10. Channel Fader
Adjusts the level if the channel signal. Use these faders to adjust the balance between the various channels.
11. 9-Band Stereo Graphic Equalizer
The graphic stereo equalizer allows you to tailor the sound to the room acoustics.
12. A. Effector Level Light
Show the effect level stronger.
B. Effector Display
Show the kind of effector
C. Mp3 Play Window
Show the MP3 time, song name and other play instruction.


Product specificaties

Merk: Power Dynamics
Categorie: Mengpaneel
Model: 172.626

Heb je hulp nodig?

Als je hulp nodig hebt met Power Dynamics 172.626 stel dan hieronder een vraag en andere gebruikers zullen je antwoorden




Handleiding Mengpaneel Power Dynamics

Handleiding Mengpaneel

Nieuwste handleidingen voor Mengpaneel