PCE Instruments PCE-USM Handleiding
PCE Instruments
Meetapparatuur
PCE-USM
Bekijk gratis de handleiding van PCE Instruments PCE-USM (6 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 47 mensen en kreeg gemiddeld 3.9 sterren uit 24 reviews. Heb je een vraag over PCE Instruments PCE-USM of wil je andere gebruikers van dit product iets vragen? Stel een vraag
Pagina 1/6

PCE-USM RS-232 - USB Logger
The logger enables the user to save the transmission data of the RS-232 interface to one or more
folders in txt format, along with the me and date. The logger can receive and retrieve data. This
means that with the right conguraon (consider pin assignment of the RS-232), the PCE-USM
adaptor can be connected with any RS- 2 interface to record the data. 23
With the scales PCE-LSM / PCE-LS / PCE-AB / PCE-ABZ / PCE-PM / PCE-TP / PCE-BDM / PCE-BT / PCE-
TB and PCE-SD Series, the PCE-USM can be plugged directly onto the RS-232 interface.
In case it is not possible to plug the adaptor directly onto the RS-232 interface, you have the
possibility to use an extension cable The standard edion comes with an external power supply. .
(12V / 100 mA mains adaptor in + / out -)

1. Connect the PCE-USM adaptor with the RS-232 interface. Then provide power supply and watch
the diodes at the PCE-USM storage adaptor. Both diodes will light up briey and the diode at the side
of the RS-232 interface should be lit now. If it does not, this normally means that the PCE-USM is not
connected to the power supply. Check the power supply If the diode at the side of the RS-232 .
interface ashes, a data transfer to the PCE-USM storage adaptor takes place.
2. Now insert the USB pen drive into the PCE-USM USB storage adaptor and watch the diodes. The
diode at the side of the RS-232 interface will ash briey and then light up permanently. During the
me the diode was ashing, a conguraon le was saved to the pen drive (see below).If the diode
at the side of the USB interface did not light up, this can mean that the USB pen drive was not
recognised or that it is full. Check the USB pen drive’s formang and, if necessary, try using another
pen drive. FAT12 / FAT16 and FAT32 formatng is possible Now try to transmit a few data to the .
PCE-USM adaptor via the RS-232 interface and watch the diodes of the PCE-USM adaptor. If the data
transmission was successful, the diode at the side of the RS-232 interface should ash rst, followed
by the diode at the side of the RS-232 interface. This ashing indicates: date received and transferred
to USB.

In case the data transmission was successfully completed, there will be two les on the USB pen
drive.
„CONFIG.TXT“ This is the conguraon le in which you can set individual parameters.
„LOG.TXT“ This is the le which contains your saved values.
The conguraon le “CONFIG.TXT“ looks as follows:
The values can easily be changed and thus adapted to your individual needs and dierent devices.
The values behind the can be changed On the right behind , you can see the possibilies of „=“ . „//“
what you can enter (allowed values).
Product specificaties
Merk: | PCE Instruments |
Categorie: | Meetapparatuur |
Model: | PCE-USM |
Heb je hulp nodig?
Als je hulp nodig hebt met PCE Instruments PCE-USM stel dan hieronder een vraag en andere gebruikers zullen je antwoorden
Handleiding Meetapparatuur PCE Instruments
16 Juni 2025
15 Juni 2025
15 Juni 2025
25 Mei 2025
22 Mei 2025
22 Mei 2025
22 Mei 2025
14 Mei 2025
14 Mei 2025
14 Mei 2025
Handleiding Meetapparatuur
- X-Rite
- Joy-it
- Continental Edison
- Steinberg
- Muller
- ORNO
- LabNation
- Benning
- Wachendorff
- Stahlwille
- Technoline
- Beckmann & Egle
- Laserliner
- Flir
- Goobay
Nieuwste handleidingen voor Meetapparatuur
16 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
15 Juni 2025
12 Juni 2025