PCE Instruments PCE-PME 250 Handleiding


Bekijk gratis de handleiding van PCE Instruments PCE-PME 250 (8 pagina’s), behorend tot de categorie Meetapparatuur. Deze gids werd als nuttig beoordeeld door 2 mensen en kreeg gemiddeld 4.6 sterren uit 1.5 reviews. Heb je een vraag over PCE Instruments PCE-PME 250 of wil je andere gebruikers van dit product iets vragen? Stel een vraag

Pagina 1/8
User manuals in various languages (français, italiano, español, português, nederlands,
türk, polski) can be found via our product search on:
www.pce-instruments.com
PCE-PME Series
USER MANUAL
ENGLISH
DIGITAL MANOMETER
2
Widely used to measure fan and blower pressure, lter resistance, air speed, furnace pressure, orice
combustion process, and monitoring blood pressure and respiratory pressure in medical care equipment.
»Measurement mode switching: Short press button 1 to change between differential pressure /
Maximum (MAX) / Minimum (MIN) / Average (AVG).
Long press button 1 to exit.
»Air pressure unit switching: Short press button 2 to change between barmbar / Pa / Kgf/cm2 / mmHg /
cmH2O / Ozf/in2 / Psi / inHg / inH2O / ftH2O / HPa / Pa.
Long press button 2 to change directly to Pa.
»Air pressure data hold/not hold: short press button 3.
»Buzzer alarm on/off: long press button 3.
Low pressure chamber High pressure chamber
A. SCOPE OF APPLICATION
B. KEY DESCRIPTION AND FUNCTION OPERATION
DEVICE DESCRIPTION
3
»Time-date switch: short press button 4.
»Barometric pressure zero calibration: long press button 4.
»Power on: short press button 5.
»Power off: long press button 5.
»Automatic shutdown function;
On: Automatie shutdown time setting: Computer application > settings > fill in the automatic shutdown
time > check the box behind the automatic shutdown > click an the upload button in this area.
O (this time): lf the automatic shutdown lunction has been opened through the computer application,
short press button 5 to display „uoff“, indicating that the automatic shutdown function is only temporarily
canceled, and the automatic shutdown function is still an alter next start-up.
O (permanently): Computer application > settings > da not check the box behind automatic shutdown >
click an this area to upload button icon.
»Record data (air pressure value, air pressure unit, time and date) function:
On: short press button 6 or computer application > settings > fill in the storage interval (1s ... 9999s) > turn
on the storage switch > Click on this area to upload the button icon;
O:
If the barometric data recording lunction has been turned on, short press button 6, or go to computer
application > settings > close the storage switch > click on the upload button icon in this area:
Clear: Press and hold button 6 or go to computer application > click on the delete storage icon;
View storage space: Computer application > settings > saved notes, the maximum number of notes that
can be stored is 15996;
View recorded data: Computer application > click on the download button icon;
Note: The more recorded data, the slower the data export time, please check the progress bar at the bot-
tom right of the computer application when exporting.
»Real-time monitoring function of pressure dala graph:
lnterval setting: Computer application > settings > lill in the measurement interval (unit: seconds);
»Operating instructions lor computer application:
Computer application > help (H) > help (H) > click „yes“ to open the help document.
»Buzzer alarm function:
On: Press and hold button 3 or go to computer application > settings > set the high alarm value > select all
the numbers including the plus and minus signs behind > press DELETE on the computer keyboard > re-
enter the alarm value, such as +2 (unit: Pa) > set the low alarm value > select all the numbers including the
plus and minus signs behind -> press DELETE on the computer keyboard -> re-enter the alarm value, such
as -3 (unit: Pa) > turn on the alarm switch > click on the upload button icon in this area;
O: Computer application > settings > turn off the alarm switch > click on the upload button icon in this
area or press and hold button 3 to turn off.
Note: The range of high and low alarm values that can be set varies depending on the pressure gauge‘s
range.


Product specificaties